These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

165 related articles for article (PubMed ID: 35136906)

  • 1. Cuffless Blood Pressure Devices.
    Bradley CK; Shimbo D; Colburn DA; Pugliese DN; Padwal R; Sia SK; Anstey DE
    Am J Hypertens; 2022 May; 35(5):380-387. PubMed ID: 35136906
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Accuracy and User Acceptability of 24-hour Ambulatory Blood Pressure Monitoring by a Prototype Cuffless Multi-Sensor Device Compared to a Conventional Oscillometric Device.
    Heimark S; Hove C; Stepanov A; Boysen ES; Gløersen Ø; Bøtke-Rasmussen KG; Gravdal HJ; Narayanapillai K; Fadl Elmula FEM; Seeberg TM; Larstorp ACK; Waldum-Grevbo B
    Blood Press; 2023 Dec; 32(1):2274595. PubMed ID: 37885101
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Cuffless blood pressure measuring devices: review and statement by the European Society of Hypertension Working Group on Blood Pressure Monitoring and Cardiovascular Variability.
    Stergiou GS; Mukkamala R; Avolio A; Kyriakoulis KG; Mieke S; Murray A; Parati G; Schutte AE; Sharman JE; Asmar R; McManus RJ; Asayama K; De La Sierra A; Head G; Kario K; Kollias A; Myers M; Niiranen T; Ohkubo T; Wang J; Wuerzner G; O'Brien E; Kreutz R; Palatini P;
    J Hypertens; 2022 Aug; 40(8):1449-1460. PubMed ID: 35708294
    [TBL] [Abstract][Full Text] [Related]  

  • 4. European Society of Hypertension recommendations for the validation of cuffless blood pressure measuring devices: European Society of Hypertension Working Group on Blood Pressure Monitoring and Cardiovascular Variability.
    Stergiou GS; Avolio AP; Palatini P; Kyriakoulis KG; Schutte AE; Mieke S; Kollias A; Parati G; Asmar R; Pantazis N; Stamoulopoulos A; Asayama K; Castiglioni P; De La Sierra A; Hahn JO; Kario K; McManus RJ; Myers M; Ohkubo T; Shroff SG; Tan I; Wang J; Zhang Y; Kreutz R; O'Brien E; Mukkamala R
    J Hypertens; 2023 Dec; 41(12):2074-2087. PubMed ID: 37303198
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Continuous cuffless and non-invasive measurement of arterial blood pressure-concepts and future perspectives.
    Pilz N; Patzak A; Bothe TL
    Blood Press; 2022 Dec; 31(1):254-269. PubMed ID: 36184775
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Cuffless Blood Pressure in clinical practice: challenges, opportunities and current limits.
    Henry B; Merz M; Hoang H; Abdulkarim G; Wosik J; Schoettker P
    Blood Press; 2024 Dec; 33(1):2304190. PubMed ID: 38245864
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The Promise and Illusion of Continuous, Cuffless Blood Pressure Monitoring.
    Hu JR; Park DY; Agarwal N; Herzig M; Ormseth G; Kaushik M; Giao DM; Turkson-Ocran RN; Juraschek SP
    Curr Cardiol Rep; 2023 Oct; 25(10):1139-1149. PubMed ID: 37688763
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Blood pressure and its variability: classic and novel measurement techniques.
    Schutte AE; Kollias A; Stergiou GS
    Nat Rev Cardiol; 2022 Oct; 19(10):643-654. PubMed ID: 35440738
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Self-measurement of blood pressure at home in the management of hypertension.
    Celis H; Den Hond E; Staessen JA
    Clin Med Res; 2005 Feb; 3(1):19-26. PubMed ID: 15962017
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Feasibility of a New Cuffless Device for Ambulatory Blood Pressure Measurement in Patients With Hypertension: Mixed Methods Study.
    Ogink PA; de Jong JM; Koeneman M; Weenk M; Engelen LJ; van Goor H; van de Belt TH; Bredie SJ
    J Med Internet Res; 2019 Jun; 21(6):e11164. PubMed ID: 31219050
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of cuff-based and cuffless continuous blood pressure measurements in children and adolescents.
    Zachwieja J; Neyman-Bartkowiak A; Rabiega A; Wojciechowska M; Barabasz M; Musielak A; Silska-Dittmar M; Ostalska-Nowicka D
    Clin Exp Hypertens; 2020 Aug; 42(6):512-518. PubMed ID: 31941385
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The Microsoft Research Aurora Project: Important Findings on Cuffless Blood Pressure Measurement.
    Mukkamala R; Shroff SG; Landry C; Kyriakoulis KG; Avolio AP; Stergiou GS
    Hypertension; 2023 Mar; 80(3):534-540. PubMed ID: 36458550
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of the Accuracy of Cuffless Blood Pressure Measurement Devices: Challenges and Proposals.
    Mukkamala R; Yavarimanesh M; Natarajan K; Hahn JO; Kyriakoulis KG; Avolio AP; Stergiou GS
    Hypertension; 2021 Nov; 78(5):1161-1167. PubMed ID: 34510915
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Current and Developing Technologies for BP Monitoring.
    Gunasekaran D; Turner JM
    Curr Cardiol Rep; 2023 Oct; 25(10):1151-1156. PubMed ID: 37698819
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The cuffless SOMNOtouch NIBP device shows poor agreement with a validated oscillometric device during 24-h ambulatory blood pressure monitoring.
    Nyvad J; Christensen KL; Buus NH; Reinhard M
    J Clin Hypertens (Greenwich); 2021 Jan; 23(1):61-70. PubMed ID: 33350030
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Clinical utility of ambulatory blood pressure monitoring in the management of hypertension.
    Angeli F; Reboldi G; Poltronieri C; Bartolini C; D'Ambrosio C; de Filippo V; Verdecchia P
    Expert Rev Cardiovasc Ther; 2014 May; 12(5):623-34. PubMed ID: 24678697
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Validation and Acceptability of a Cuffless Wrist-Worn Wearable Blood Pressure Monitoring Device Among Users and Health Care Professionals: Mixed Methods Study.
    Islam SMS; Cartledge S; Karmakar C; Rawstorn JC; Fraser SF; Chow C; Maddison R
    JMIR Mhealth Uhealth; 2019 Sep; 7(10):e14706. PubMed ID: 31628788
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The 2020 "WHO Technical Specifications for Automated Non-Invasive Blood Pressure Measuring Devices With Cuff".
    John O; Campbell NRC; Brady TM; Farrell M; Varghese C; Velazquez Berumen A; Velez Ruiz Gaitan LA; Toffelmire N; Ameel M; Mideksa M; Jaffe MG; Schutte AE; Khan T; Lopez Meneses LP
    Hypertension; 2021 Mar; 77(3):806-812. PubMed ID: 33517681
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Call to action on use and reimbursement for home blood pressure monitoring: a joint scientific statement from the American Heart Association, American Society Of Hypertension, and Preventive Cardiovascular Nurses Association.
    Pickering TG; Miller NH; Ogedegbe G; Krakoff LR; Artinian NT; Goff D; ; ;
    Hypertension; 2008 Jul; 52(1):10-29. PubMed ID: 18497370
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Call to action on use and reimbursement for home blood pressure monitoring: executive summary: a joint scientific statement from the American Heart Association, American Society Of Hypertension, and Preventive Cardiovascular Nurses Association.
    Pickering TG; Miller NH; Ogedegbe G; Krakoff LR; Artinian NT; Goff D; ; ;
    Hypertension; 2008 Jul; 52(1):1-9. PubMed ID: 18497371
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.