These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

102 related articles for article (PubMed ID: 3514023)

  • 1. Histologic and microradiographic analysis of a revised porous-coated anatomic (PCA) patellar component. A case report.
    Cook SD; Scheller AD; Anderson RC; Haddad RJ
    Clin Orthop Relat Res; 1986 Jan; (202):147-51. PubMed ID: 3514023
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Bilateral tibial components of different cementless designs and materials. Microradiographic, backscattered imaging, and histologic analysis.
    Bloebaum RD; Rhodes DM; Rubman MH; Hofmann AA
    Clin Orthop Relat Res; 1991 Jul; (268):179-87. PubMed ID: 2060206
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Quantitative histologic analysis of tissue growth into porous total knee components.
    Cook SD; Barrack RL; Thomas KA; Haddad RJ
    J Arthroplasty; 1989; 4 Suppl():S33-43. PubMed ID: 2584985
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A histomorphometric and histologic analysis of the implant interface in five successful, autopsy-retrieved, noncemented porous-coated knee arthroplasties.
    Vigorita VJ; Minkowitz B; Dichiara JF; Higham PA
    Clin Orthop Relat Res; 1993 Aug; (293):211-8. PubMed ID: 8339483
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Bone growth into a revised porous-coated patellar implant.
    Jensen LN; Lund B; Gotfredsen K
    Acta Orthop Scand; 1990 Jun; 61(3):213-6. PubMed ID: 2371813
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The clinical and roentgenographic results of cementless porous-coated patellar fixation.
    Firestone TP; Teeny SM; Krackow KA; Hungerford DS
    Clin Orthop Relat Res; 1991 Dec; (273):184-9. PubMed ID: 1959269
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Histologic analysis of retrieved human porous-coated total joint components.
    Cook SD; Thomas KA; Haddad RJ
    Clin Orthop Relat Res; 1988 Sep; (234):90-101. PubMed ID: 3409607
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The use of metal-backed patellar prostheses in total knee arthroplasty.
    Laskin RS; Bucknell A
    Clin Orthop Relat Res; 1990 Nov; (260):52-5. PubMed ID: 2225642
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Radiographic and histologic study of porous coated tibial component fixation in cementless total knee arthroplasty.
    Engh GA; Bobyn JD; Petersen TL
    Orthopedics; 1988 May; 11(5):725-31. PubMed ID: 3399443
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Bone ingrowth into porous-coated tibial components implanted with autograft bone chips. Analysis of ten consecutively retrieved implants.
    Bloebaum RD; Rubman MH; Hofmann AA
    J Arthroplasty; 1992 Dec; 7(4):483-93. PubMed ID: 1479367
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Osteolysis around cementless porous-coated anatomic knee prostheses.
    Kim YH; Oh JH; Oh SH
    J Bone Joint Surg Br; 1995 Mar; 77(2):236-41. PubMed ID: 7706337
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of bone ingrowth into cobalt chrome sphere and titanium fiber mesh porous coated cementless canine acetabular components.
    Jasty M; Bragdon CR; Haire T; Mulroy RD; Harris WH
    J Biomed Mater Res; 1993 May; 27(5):639-44. PubMed ID: 8314816
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Total knee replacement: radiologic findings in failure of porous-coated metal-backed patellar component.
    Piraino D; Richmond B; Freed H; Belhobek G; Schils J; Stulberg B
    AJR Am J Roentgenol; 1990 Sep; 155(3):555-8. PubMed ID: 2117356
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of the anatomic patellar prosthesis in uncemented porous-coated total knee arthroplasty: seven-year results.
    Kim YH; Oh JH
    Am J Orthop (Belle Mead NJ); 1995 May; 24(5):412-9. PubMed ID: 7620863
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Porous-coated knee arthroplasty. A case report concerning bone ingrowth.
    Hainau B; Reimann I; Dorph S; Rechnagel K; Henschel A; Kragh F
    Clin Orthop Relat Res; 1989 Feb; (239):178-84. PubMed ID: 2912618
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A metal-backed, rotating-bearing patellar prosthesis to lower contact stress. An 11-year clinical study.
    Buechel FF; Rosa RA; Pappas MJ
    Clin Orthop Relat Res; 1989 Nov; (248):34-49. PubMed ID: 2805494
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The effect of the design of the femoral component on the conformity of the patellofemoral joint in total knee replacement.
    Ma HM; Lu YC; Kwok TG; Ho FY; Huang CY; Huang CH
    J Bone Joint Surg Br; 2007 Mar; 89(3):408-12. PubMed ID: 17356162
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Cementless total joint arthroplasty prostheses with titanium-alloy articular surfaces. A human retrieval analysis.
    Nasser S; Campbell PA; Kilgus D; Kossovsky N; Amstutz HC
    Clin Orthop Relat Res; 1990 Dec; (261):171-85. PubMed ID: 2245543
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Fractographic analysis of failed porous and surface-coated cobalt-chromium alloy total joint replacements.
    Kohn DH; Ducheyne P; Cuckler JM; Chu AC; Radin S
    Med Prog Technol; 1994; 20(3-4):169-77. PubMed ID: 7877561
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Measuring the volume fraction of bone ingrowth: a comparison of three techniques.
    Sumner DR; Bryan JM; Urban RM; Kuszak JR
    J Orthop Res; 1990 May; 8(3):448-52. PubMed ID: 2182802
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.