These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

148 related articles for article (PubMed ID: 35147418)

  • 21. Electrochemical genosensor based on carbon nanotube/amine-ionic liquid functionalized reduced graphene oxide nanoplatform for detection of human papillomavirus (HPV16)-related head and neck cancer.
    Farzin L; Sadjadi S; Shamsipur M; Sheibani S
    J Pharm Biomed Anal; 2020 Feb; 179():112989. PubMed ID: 31767223
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Application of chitosan/Fe₃O₄ microsphere-graphene composite modified carbon ionic liquid electrode for the electrochemical detection of the PCR product of soybean Lectin gene sequence.
    Sun W; Qi X; Chen Y; Liu S; Gao H
    Talanta; 2011 Dec; 87():106-12. PubMed ID: 22099656
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Electrochemical label-free and sensitive nanobiosensing of DNA hybridization by graphene oxide modified pencil graphite electrode.
    Ahour F; Shamsi A
    Anal Biochem; 2017 Sep; 532():64-71. PubMed ID: 28606426
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Electrochemical sensing and biosensing platform based on chemically reduced graphene oxide.
    Zhou M; Zhai Y; Dong S
    Anal Chem; 2009 Jul; 81(14):5603-13. PubMed ID: 19522529
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Ultrasensitive DNA sensor based on gold nanoparticles/reduced graphene oxide/glassy carbon electrode.
    Benvidi A; Firouzabadi AD; Moshtaghiun SM; Mazloum-Ardakani M; Tezerjani MD
    Anal Biochem; 2015 Sep; 484():24-30. PubMed ID: 25988596
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Carbon quantum dots encapsulated in super small platinum nanocrystals core-shell architecture/nitrogen doped graphene hybrid nanocomposite for electrochemical biosensing of DNA damage biomarker-8-hydroxy-2'-deoxyguanosine.
    Zhang Q; Zhao Q; Fu M; Fan X; Lu H; Wang H; Zhang Y; Wang H
    Anal Chim Acta; 2019 Jan; 1047():9-20. PubMed ID: 30567668
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Amino acid-functionalized carbon quantum dots for selective detection of Al
    Yan C; Guo L; Shao X; Shu Q; Guan P; Wang J; Hu X; Wang C
    Anal Bioanal Chem; 2021 Jun; 413(15):3965-3974. PubMed ID: 33909083
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Carbon dot-based biosensors for the detection of communicable and non -communicable diseases.
    Barrientos K; Arango JP; Moncada MS; Placido J; Patiño J; Macías SL; Maldonado C; Torijano S; Bustamante S; Londoño ME; Jaramillo M
    Talanta; 2023 Jan; 251():123791. PubMed ID: 35987023
    [TBL] [Abstract][Full Text] [Related]  

  • 29. A label-free electrochemical immunosensor for the detection of cardiac marker using graphene quantum dots (GQDs).
    Tuteja SK; Chen R; Kukkar M; Song CK; Mutreja R; Singh S; Paul AK; Lee H; Kim KH; Deep A; Suri CR
    Biosens Bioelectron; 2016 Dec; 86():548-556. PubMed ID: 27448545
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Fe(3+)-functionalized carbon quantum dots: A facile preparation strategy and detection for ascorbic acid in rat brain microdialysates.
    Li L; Wang C; Luo J; Guo Q; Liu K; Liu K; Zhao W; Lin Y
    Talanta; 2015 Nov; 144():1301-7. PubMed ID: 26452962
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Graphene electrode modified with electrochemically reduced graphene oxide for label-free DNA detection.
    Li B; Pan G; Avent ND; Lowry RB; Madgett TE; Waines PL
    Biosens Bioelectron; 2015 Oct; 72():313-9. PubMed ID: 26002015
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Electrochemiluminescent immunoassay for neuron specific enolase by using amino-modified reduced graphene oxide loaded with N-doped carbon quantum dots.
    Zheng X; Mo G; He Y; Qin D; Jiang X; Mo W; Deng B
    Mikrochim Acta; 2019 Nov; 186(12):817. PubMed ID: 31749073
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Exonuclease I-assisted fluorescent method for ochratoxin A detection using iron-doped porous carbon, nitrogen-doped graphene quantum dots, and double magnetic separation.
    Wang C; Tan R; Li J; Zhang Z
    Anal Bioanal Chem; 2019 Apr; 411(11):2405-2414. PubMed ID: 30828760
    [TBL] [Abstract][Full Text] [Related]  

  • 34. A Label-Free Electrochemical Biosensor Based on a Reduced Graphene Oxide and Indole-5-Carboxylic Acid Nanocomposite for the Detection of
    Zhang Z; Yu HW; Wan GC; Jiang JH; Wang N; Liu ZY; Chang D; Pan HZ
    J AOAC Int; 2017 Mar; 100(2):548-552. PubMed ID: 28118564
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Molecular machine and gold/graphene quantum dot hybrid based dual amplification strategy for voltammetric detection of VEGF165.
    Hongxia C; Zaijun L; Ruiyi L; Guangli W; Zhiguo G
    Mikrochim Acta; 2019 Mar; 186(4):242. PubMed ID: 30877385
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Electrolyte-Gated Graphene Ambipolar Frequency Multipliers for Biochemical Sensing.
    Fu W; Feng L; Mayer D; Panaitov G; Kireev D; Offenhäusser A; Krause HJ
    Nano Lett; 2016 Apr; 16(4):2295-300. PubMed ID: 26928906
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Dual amplification in a fluorometric acetamiprid assay by using an aptamer, G-quadruplex/hemin DNAzyme, and graphene quantum dots functionalized with D-penicillamine and histidine.
    Nana L; Ruiyi L; Xiulan S; Yongqiang Y; Zaijun L
    Mikrochim Acta; 2020 Feb; 187(3):158. PubMed ID: 32034503
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Signal amplification aptamer biosensor for thrombin based on a glassy carbon electrode modified with graphene, quantum dots and gold nanoparticles.
    Xie L; You L; Cao X
    Spectrochim Acta A Mol Biomol Spectrosc; 2013 May; 109():110-5. PubMed ID: 23501724
    [TBL] [Abstract][Full Text] [Related]  

  • 39. A novel electrochemiluminescent immunosensor based on the quenching effect of aminated graphene on nitrogen-doped carbon quantum dots.
    Zhou J; Han T; Ma H; Yan T; Pang X; Li Y; Wei Q
    Anal Chim Acta; 2015 Aug; 889():82-9. PubMed ID: 26343429
    [TBL] [Abstract][Full Text] [Related]  

  • 40. An ultrasensitive and selective electrochemical aptasensor based on rGO-MWCNTs/Chitosan/carbon quantum dot for the detection of lysozyme.
    Rezaei B; Jamei HR; Ensafi AA
    Biosens Bioelectron; 2018 Sep; 115():37-44. PubMed ID: 29793133
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.