These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
301 related articles for article (PubMed ID: 35157574)
1. An Affordable and Easy-to-Use Focused Ultrasound Device for Noninvasive and High Precision Drug Delivery to the Mouse Brain. Hu Z; Chen S; Yang Y; Gong Y; Chen H IEEE Trans Biomed Eng; 2022 Sep; 69(9):2723-2732. PubMed ID: 35157574 [TBL] [Abstract][Full Text] [Related]
2. Transcranial blood-brain barrier opening in Alzheimer's disease patients using a portable focused ultrasound system with real-time 2-D cavitation mapping. Bae S; Liu K; Pouliopoulos AN; Ji R; Jiménez-Gambín S; Yousefian O; Kline-Schoder AR; Batts AJ; Tsitsos FN; Kokossis D; Mintz A; Honig LS; Konofagou EE Theranostics; 2024; 14(11):4519-4535. PubMed ID: 39113808 [No Abstract] [Full Text] [Related]
3. Targeted delivery of therapeutic agents to the mouse brain using a stereotactic-guided focused ultrasound device. Hu Z; Yang Y; Ye D; Chen S; Gong Y; Chukwu C; Chen H STAR Protoc; 2023 Mar; 4(1):102132. PubMed ID: 36861835 [TBL] [Abstract][Full Text] [Related]
4. Comparison of Sonication Patterns and Microbubble Administration Strategies for Focused Ultrasound-Mediated Large-Volume Drug Delivery. Gong Y; Ye D; Chien CY; Yue Y; Chen H IEEE Trans Biomed Eng; 2022 Nov; 69(11):3449-3459. PubMed ID: 35476579 [TBL] [Abstract][Full Text] [Related]
5. Monitoring of acoustic cavitation in microbubble-presented focused ultrasound exposure using gradient-echo MRI. Wu CH; Liu HL; Ho CT; Hsu PH; Fan CH; Yeh CK; Kang ST; Chen WS; Wang FN; Peng HH J Magn Reson Imaging; 2020 Jan; 51(1):311-318. PubMed ID: 31125166 [TBL] [Abstract][Full Text] [Related]
6. Submicron-bubble-enhanced focused ultrasound for blood-brain barrier disruption and improved CNS drug delivery. Fan CH; Liu HL; Ting CY; Lee YH; Huang CY; Ma YJ; Wei KC; Yen TC; Yeh CK PLoS One; 2014; 9(5):e96327. PubMed ID: 24788566 [TBL] [Abstract][Full Text] [Related]
7. Focused Ultrasound-Induced Blood-Brain Barrier Opening: Association with Mechanical Index and Cavitation Index Analyzed by Dynamic Contrast-Enhanced Magnetic-Resonance Imaging. Chu PC; Chai WY; Tsai CH; Kang ST; Yeh CK; Liu HL Sci Rep; 2016 Sep; 6():33264. PubMed ID: 27630037 [TBL] [Abstract][Full Text] [Related]
8. Blood-brain barrier opening in a large animal model using closed-loop microbubble cavitation-based feedback control of focused ultrasound sonication. Chien CY; Xu L; Pacia CP; Yue Y; Chen H Sci Rep; 2022 Sep; 12(1):16147. PubMed ID: 36167747 [TBL] [Abstract][Full Text] [Related]
9. Efficiency of drug delivery enhanced by acoustic pressure during blood-brain barrier disruption induced by focused ultrasound. Yang FY; Lee PY Int J Nanomedicine; 2012; 7():2573-82. PubMed ID: 22679368 [TBL] [Abstract][Full Text] [Related]
10. Cavitation-modulated inflammatory response following focused ultrasound blood-brain barrier opening. Ji R; Karakatsani ME; Burgess M; Smith M; Murillo MF; Konofagou EE J Control Release; 2021 Sep; 337():458-471. PubMed ID: 34324895 [TBL] [Abstract][Full Text] [Related]
11. Influence of focused ultrasound on locoregional drug delivery to the brain: Potential implications for brain tumor therapy. Uribe Cardenas R; Laramee M; Ray I; Dahmane N; Souweidane M; Martin B J Control Release; 2023 Oct; 362():755-763. PubMed ID: 37659767 [TBL] [Abstract][Full Text] [Related]
13. Dependence of the reversibility of focused- ultrasound-induced blood-brain barrier opening on pressure and pulse length in vivo. Samiotaki G; Konofagou EE IEEE Trans Ultrason Ferroelectr Freq Control; 2013 Nov; 60(11):2257-65. PubMed ID: 24158283 [TBL] [Abstract][Full Text] [Related]
14. Feasibility of Hologram-Assisted Bilateral Blood-Brain Barrier Opening in Non-Human Primates. Jimenez-Gambin S; Bae S; Ji R; Tsitsos F; Konofagou EE IEEE Trans Ultrason Ferroelectr Freq Control; 2024 Oct; 71(10):1172-1185. PubMed ID: 39196737 [TBL] [Abstract][Full Text] [Related]
16. Transcranial Blood-Brain Barrier Opening in Alzheimer's Disease Patients Using a Portable Focused Ultrasound System with Real-Time 2-D Cavitation Mapping. Bae S; Liu K; Pouliopoulos AN; Ji R; Jiménez-Gambín S; Yousefian O; Kline-Schoder AR; Batts AJ; Tsitsos FN; Kokossis D; Mintz A; Honig LS; Konofagou EE medRxiv; 2024 May; ():. PubMed ID: 38196636 [TBL] [Abstract][Full Text] [Related]
17. Focused ultrasound-mediated blood-brain barrier opening is safe and feasible with moderately hypofractionated radiotherapy for brainstem diffuse midline glioma. Tazhibi M; McQuillan N; Wei HJ; Gallitto M; Bendau E; Webster Carrion A; Berg X; Kokossis D; Zhang X; Zhang Z; Jan CI; Mintz A; Gartrell RD; Syed HR; Fonseca A; Pavisic J; Szalontay L; Konofagou EE; Zacharoulis S; Wu CC J Transl Med; 2024 Mar; 22(1):320. PubMed ID: 38555449 [TBL] [Abstract][Full Text] [Related]
18. Three-dimensional transcranial microbubble imaging for guiding volumetric ultrasound-mediated blood-brain barrier opening. Jones RM; Deng L; Leung K; McMahon D; O'Reilly MA; Hynynen K Theranostics; 2018; 8(11):2909-2926. PubMed ID: 29896293 [TBL] [Abstract][Full Text] [Related]
19. Focused ultrasound-mediated noninvasive blood-brain barrier modulation: preclinical examination of efficacy and safety in various sonication parameters. Shin J; Kong C; Cho JS; Lee J; Koh CS; Yoon MS; Na YC; Chang WS; Chang JW Neurosurg Focus; 2018 Feb; 44(2):E15. PubMed ID: 29385915 [TBL] [Abstract][Full Text] [Related]
20. Contrast-enhanced ultrasound imaging for the detection of focused ultrasound-induced blood-brain barrier opening. Fan CH; Lin WH; Ting CY; Chai WY; Yen TC; Liu HL; Yeh CK Theranostics; 2014; 4(10):1014-25. PubMed ID: 25161701 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]