These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
201 related articles for article (PubMed ID: 35161936)
1. Optimal Control of Air Conditioning Systems by Means of CO Muratori L; Peretto L; Pulvirenti B; Di Sante R; Bottiglieri G; Coiro F Sensors (Basel); 2022 Feb; 22(3):. PubMed ID: 35161936 [TBL] [Abstract][Full Text] [Related]
2. Optimization of air quality and energy consumption in the cabin of electric vehicles using system simulation. Lesage M; Chalet D; Migaud J; Krautner C J Environ Manage; 2024 May; 358():120861. PubMed ID: 38603848 [TBL] [Abstract][Full Text] [Related]
3. In-vehicle carbon dioxide concentration in commuting cars in Bangkok, Thailand. Luangprasert M; Vasithamrong C; Pongratananukul S; Chantranuwathana S; Pumrin S; De Silva IP J Air Waste Manag Assoc; 2017 May; 67(5):623-633. PubMed ID: 27960651 [TBL] [Abstract][Full Text] [Related]
4. Fuzzy Logic Controlled Simulation in Regulating Thermal Comfort and Indoor Air Quality Using a Vehicle Heating, Ventilation, and Air-Conditioning System. Rajeswari Subramaniam K; Cheng CT; Pang TY Sensors (Basel); 2023 Jan; 23(3):. PubMed ID: 36772432 [TBL] [Abstract][Full Text] [Related]
5. Assessment of indoor levels of volatile organic compounds and carbon dioxide in schools in Kuwait. Al-Awadi L J Air Waste Manag Assoc; 2018 Jan; 68(1):54-72. PubMed ID: 28829721 [TBL] [Abstract][Full Text] [Related]
6. Vehicle cabin air quality: influence of air recirculation on energy use, particles, and CO Wei D; Nielsen F; Karlsson H; Ekberg L; Dalenbäck JO Environ Sci Pollut Res Int; 2023 Mar; 30(15):43387-43402. PubMed ID: 36656477 [TBL] [Abstract][Full Text] [Related]
7. Air Quality and Comfort Characterisation within an Electric Vehicle Cabin in Heating and Cooling Operations. Russi L; Guidorzi P; Pulvirenti B; Aguiari D; Pau G; Semprini G Sensors (Basel); 2022 Jan; 22(2):. PubMed ID: 35062503 [TBL] [Abstract][Full Text] [Related]
8. A systematic review and meta-analysis of indoor bioaerosols in hospitals: The influence of heating, ventilation, and air conditioning. Dai R; Liu S; Li Q; Wu H; Wu L; Ji C PLoS One; 2021; 16(12):e0259996. PubMed ID: 34941879 [TBL] [Abstract][Full Text] [Related]
9. Sustainability of Heating, Ventilation and Air-Conditioning (HVAC) Systems in Buildings-An Overview. Asim N; Badiei M; Mohammad M; Razali H; Rajabi A; Chin Haw L; Jameelah Ghazali M Int J Environ Res Public Health; 2022 Jan; 19(2):. PubMed ID: 35055838 [TBL] [Abstract][Full Text] [Related]
10. Changes in airborne fungi from the outdoors to indoor air; large HVAC systems in nonproblem buildings in two different climates. Kemp PC; Neumeister-Kemp HG; Esposito B; Lysek G; Murray F AIHA J (Fairfax, Va); 2003; 64(2):269-75. PubMed ID: 12688852 [TBL] [Abstract][Full Text] [Related]
11. Heating, ventilation and air conditioning (HVAC) in intensive care unit. Saran S; Gurjar M; Baronia A; Sivapurapu V; Ghosh PS; Raju GM; Maurya I Crit Care; 2020 May; 24(1):194. PubMed ID: 32375844 [TBL] [Abstract][Full Text] [Related]
12. Returning characteristics of pollutants for a local domain in the presence of returning and recirculating airflow in indoor environments. Lim E; Sandberg M; Ito K Indoor Air; 2021 Jul; 31(4):1267-1280. PubMed ID: 33605467 [TBL] [Abstract][Full Text] [Related]
13. Effect of ventilation rate on air cleanliness and energy consumption in operation rooms at rest. Lee ST; Liang CC; Chien TY; Wu FJ; Fan KC; Wan GH Environ Monit Assess; 2018 Feb; 190(3):178. PubMed ID: 29488020 [TBL] [Abstract][Full Text] [Related]
14. Review and Extension of CO₂-Based Methods to Determine Ventilation Rates with Application to School Classrooms. Batterman S Int J Environ Res Public Health; 2017 Feb; 14(2):. PubMed ID: 28165398 [TBL] [Abstract][Full Text] [Related]
15. Developing air exchange rate models by evaluating vehicle in-cabin air pollutant exposures in a highway and tunnel setting: case study of Tehran, Iran. Nayeb Yazdi M; Arhami M; Delavarrafiee M; Ketabchy M Environ Sci Pollut Res Int; 2019 Jan; 26(1):501-513. PubMed ID: 30406592 [TBL] [Abstract][Full Text] [Related]
16. Effectiveness of photocatalytic filter for removing volatile organic compounds in the heating, ventilation, and air conditioning system. Yu KP; Lee GW; Huang WM; Wu CC; Lou CL; Yang S J Air Waste Manag Assoc; 2006 May; 56(5):666-74. PubMed ID: 16739804 [TBL] [Abstract][Full Text] [Related]
17. [Air quality control systems: heating, ventilating, and air conditioning (HVAC)]. Bellucci Sessa R; Riccio G G Ital Med Lav Ergon; 2004; 26(4):375-81. PubMed ID: 15584448 [TBL] [Abstract][Full Text] [Related]
18. Application of a high-efficiency cabin air filter for simultaneous mitigation of ultrafine particle and carbon dioxide exposures inside passenger vehicles. Lee ES; Zhu Y Environ Sci Technol; 2014 Feb; 48(4):2328-35. PubMed ID: 24471775 [TBL] [Abstract][Full Text] [Related]
19. Estimation of optimum requirements for indoor air quality and energy consumption in some residences in Kuwait. Elkilani A; Bouhamra W Environ Int; 2001 Dec; 27(6):443-7. PubMed ID: 11800426 [TBL] [Abstract][Full Text] [Related]
20. Carbon Dioxide Detection and Indoor Air Quality Control. Bonino S Occup Health Saf; 2016 Apr; 85(4):46-8. PubMed ID: 27183813 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]