BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

371 related articles for article (PubMed ID: 35161984)

  • 1. Breath Analysis: A Promising Tool for Disease Diagnosis-The Role of Sensors.
    Kaloumenou M; Skotadis E; Lagopati N; Efstathopoulos E; Tsoukalas D
    Sensors (Basel); 2022 Feb; 22(3):. PubMed ID: 35161984
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evolution of clinical and environmental health applications of exhaled breath research: Review of methods and instrumentation for gas-phase, condensate, and aerosols.
    Wallace MAG; Pleil JD
    Anal Chim Acta; 2018 Sep; 1024():18-38. PubMed ID: 29776545
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparative analysis of volatile organic compounds of breath and urine for distinguishing patients with liver cirrhosis from healthy controls by using electronic nose and voltammetric electronic tongue.
    Zaim O; Diouf A; El Bari N; Lagdali N; Benelbarhdadi I; Ajana FZ; Llobet E; Bouchikhi B
    Anal Chim Acta; 2021 Nov; 1184():339028. PubMed ID: 34625262
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Sensors for Enhanced Detection of Acetone as a Potential Tool for Noninvasive Diabetes Monitoring.
    Rydosz A
    Sensors (Basel); 2018 Jul; 18(7):. PubMed ID: 30012960
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Exhaled Breath Analysis for Diabetes Diagnosis and Monitoring: Relevance, Challenges and Possibilities.
    Dixit K; Fardindoost S; Ravishankara A; Tasnim N; Hoorfar M
    Biosensors (Basel); 2021 Nov; 11(12):. PubMed ID: 34940233
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Sensors for breath testing: from nanomaterials to comprehensive disease detection.
    Konvalina G; Haick H
    Acc Chem Res; 2014 Jan; 47(1):66-76. PubMed ID: 23926883
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Detection of volatile organic compounds (VOCs) from exhaled breath as noninvasive methods for cancer diagnosis.
    Sun X; Shao K; Wang T
    Anal Bioanal Chem; 2016 Apr; 408(11):2759-80. PubMed ID: 26677028
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Investigation of Exhaled Breath Samples from Patients with Alzheimer's Disease Using Gas Chromatography-Mass Spectrometry and an Exhaled Breath Sensor System.
    Lau HC; Yu JB; Lee HW; Huh JS; Lim JO
    Sensors (Basel); 2017 Aug; 17(8):. PubMed ID: 28771180
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Influences of mixed expiratory sampling parameters on exhaled volatile organic compound concentrations.
    Thekedar B; Oeh U; Szymczak W; Hoeschen C; Paretzke HG
    J Breath Res; 2011 Mar; 5(1):016001. PubMed ID: 21383425
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Breath Testing in the Surgical Setting: Applications, Challenges, and Future Perspectives.
    Walsh CM; Fadel MG; Jamel SH; Hanna GB
    Eur Surg Res; 2023; 64(3):315-322. PubMed ID: 37311421
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Simultaneous determination of exhaled breath vapor and exhaled breath aerosol using filter-incorporated needle-trap devices: A comparison of gas-phase and droplet-bound components.
    Zeinali S; Ghosh C; Pawliszyn J
    Anal Chim Acta; 2022 Apr; 1203():339671. PubMed ID: 35361425
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evidence of endogenous volatile organic compounds as biomarkers of diseases in alveolar breath.
    Sarbach C; Stevens P; Whiting J; Puget P; Humbert M; Cohen-Kaminsky S; Postaire E
    Ann Pharm Fr; 2013 Jul; 71(4):203-15. PubMed ID: 23835018
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Exhaled breath testing - A tool for the clinician and researcher.
    Davis MD; Fowler SJ; Montpetit AJ
    Paediatr Respir Rev; 2019 Feb; 29():37-41. PubMed ID: 29921519
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Detecting cancer by breath volatile organic compound analysis: a review of array-based sensors.
    Queralto N; Berliner AN; Goldsmith B; Martino R; Rhodes P; Lim SH
    J Breath Res; 2014 Jun; 8(2):027112. PubMed ID: 24862241
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Analysis of volatile organic compounds in the breath of patients with stable or acute exacerbation of chronic obstructive pulmonary disease.
    Pizzini A; Filipiak W; Wille J; Ager C; Wiesenhofer H; Kubinec R; Blaško J; Tschurtschenthaler C; Mayhew CA; Weiss G; Bellmann-Weiler R
    J Breath Res; 2018 Mar; 12(3):036002. PubMed ID: 29295966
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Breath Biomarkers in Diagnostic Applications.
    Pham YL; Beauchamp J
    Molecules; 2021 Sep; 26(18):. PubMed ID: 34576985
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Exhaled breath and fecal volatile organic biomarkers of chronic kidney disease.
    Meinardi S; Jin KB; Barletta B; Blake DR; Vaziri ND
    Biochim Biophys Acta; 2013 Mar; 1830(3):2531-7. PubMed ID: 23274524
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A Metal Oxide Gas Sensors Array for Lung Cancer Diagnosis Through Exhaled Breath Analysis.
    Marzorati D; Mainardi L; Sedda G; Gasparri R; Spaggiari L; Cerveri P
    Annu Int Conf IEEE Eng Med Biol Soc; 2019 Jul; 2019():1584-1587. PubMed ID: 31946198
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Breathomics from exhaled volatile organic compounds in pediatric asthma.
    Neerincx AH; Vijverberg SJH; Bos LDJ; Brinkman P; van der Schee MP; de Vries R; Sterk PJ; Maitland-van der Zee AH
    Pediatr Pulmonol; 2017 Dec; 52(12):1616-1627. PubMed ID: 29082668
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Towards standardization in the analysis of breath gas volatiles.
    Herbig J; Beauchamp J
    J Breath Res; 2014 Sep; 8(3):037101. PubMed ID: 25189420
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 19.