167 related articles for article (PubMed ID: 35162557)
1. Simulation Studies Provide Evidence of Aerosol Transmission of SARS-CoV-2 in a Multi-Story Building via Air Supply, Exhaust and Sanitary Pipelines.
Zhang Z; Li X; Wang Q; Zhao X; Xu J; Jiang Q; Jiang S; Lyu J; Liu S; Ye L; Yuan J; Feng W; Xie J; Chen Q; Zou H; Xu D
Int J Environ Res Public Health; 2022 Jan; 19(3):. PubMed ID: 35162557
[TBL] [Abstract][Full Text] [Related]
2. Exploring the Transmission Path, Influencing Factors and Risk of Aerosol Transmission of SARS-CoV-2 at Xi'an Xianyang International Airport.
Zhang Z; Li X; Lyu K; Zhao X; Zhang F; Liu D; Zhao Y; Gao F; Hu J; Xu D
Int J Environ Res Public Health; 2023 Jan; 20(1):. PubMed ID: 36613187
[TBL] [Abstract][Full Text] [Related]
3. Probable Aerosol Transmission of SARS-CoV-2 through Floors and Walls of Quarantine Hotel, Taiwan, 2021.
Wei HY; Chang CP; Liu MT; Mu JJ; Lin YJ; Dai YT; Su CP
Emerg Infect Dis; 2022 Dec; 28(12):2374-2382. PubMed ID: 36322955
[TBL] [Abstract][Full Text] [Related]
4. SARS-CoV-2 Aerosol Transmission Through Vertical Sanitary Drains in High-Rise Buildings - Shenzhen, Guangdong Province, China, March 2022.
Lyu K; Feng S; Li X; Wang Q; Zhao X; Yu S; Zheng P; Ji J; Chen G; Liang J; Lan T; Feng J; Jiang S; Lu J; Xia T; Peng C; Feng T; Xu D
China CDC Wkly; 2022 Jun; 4(23):489-493. PubMed ID: 35813264
[TBL] [Abstract][Full Text] [Related]
5. Research on the relationship between architectural features in northeast China and vertical aerosol transmission of COVID-19.
Li X; Sun B; Lyu K; Chen J; Zhang Y; Sun Y; Li C; Sui T; Wang X; Hu Y; Wang Q; Xu D
Front Public Health; 2022; 10():1052610. PubMed ID: 36711357
[TBL] [Abstract][Full Text] [Related]
6. Toilets dominate environmental detection of severe acute respiratory syndrome coronavirus 2 in a hospital.
Ding Z; Qian H; Xu B; Huang Y; Miao T; Yen HL; Xiao S; Cui L; Wu X; Shao W; Song Y; Sha L; Zhou L; Xu Y; Zhu B; Li Y
Sci Total Environ; 2021 Jan; 753():141710. PubMed ID: 32891988
[TBL] [Abstract][Full Text] [Related]
7. Vertical transmission of infectious aerosols through building toilet drainage system: An experimental study.
Niu Y; Wang F; Luo D; Shu Z; Huang J; Zhang Y; Liu C; Qian H
Environ Pollut; 2024 Feb; 343():123284. PubMed ID: 38163630
[TBL] [Abstract][Full Text] [Related]
8. Factors affecting aerosol SARS-CoV-2 transmission via HVAC systems; a modeling study.
Cotman ZJ; Bowden MJ; Richter BP; Phelps JH; Dibble CJ
PLoS Comput Biol; 2021 Oct; 17(10):e1009474. PubMed ID: 34662342
[TBL] [Abstract][Full Text] [Related]
9. Ventilation strategies based on an aerodynamic analysis during a large-scale SARS-CoV-2 outbreak in an acute-care hospital.
Park SY; Yu J; Bae S; Song JS; Lee SY; Kim JH; Jeong YS; Oh SM; Kim TH; Lee E
J Clin Virol; 2023 Aug; 165():105502. PubMed ID: 37327553
[TBL] [Abstract][Full Text] [Related]
10. Quantifying the risk of indoor drainage system in multi-unit apartment building as a transmission route of SARS-CoV-2.
Shi KW; Huang YH; Quon H; Ou-Yang ZL; Wang C; Jiang SC
Sci Total Environ; 2021 Mar; 762():143056. PubMed ID: 33268249
[TBL] [Abstract][Full Text] [Related]
11. Probable Evidence of Aerosol Transmission of SARS-COV-2 in a COVID-19 Outbreak of a High-Rise Building.
Jiang X; Zhao C; Chen Y; Gao X; Zhang Q; Chen Z; Li C; Zhao X; Liu Z; Huang W; Xie W; Yue Y
Environ Health Insights; 2023; 17():11786302231188269. PubMed ID: 37522029
[TBL] [Abstract][Full Text] [Related]
12. Aerosol transmission of SARS-CoV-2 due to the chimney effect in two high-rise housing drainage stacks.
Wang Q; Li Y; Lung DC; Chan PT; Dung CH; Jia W; Miao T; Huang J; Chen W; Wang Z; Leung KM; Lin Z; Wong D; Tse H; Wong SCY; Choi GK; Lam JY; To KK; Cheng VC; Yuen KY
J Hazard Mater; 2022 Jan; 421():126799. PubMed ID: 34396958
[TBL] [Abstract][Full Text] [Related]
13. Identification of SARS-CoV-2 RNA in healthcare heating, ventilation, and air conditioning units.
Horve PF; Dietz LG; Fretz M; Constant DA; Wilkes A; Townes JM; Martindale RG; Messer WB; Van Den Wymelenberg KG
Indoor Air; 2021 Nov; 31(6):1826-1832. PubMed ID: 34189769
[TBL] [Abstract][Full Text] [Related]
14. Evaluation of aerosol transmission risk during home quarantine under different operating scenarios: A pilot study.
Cheung T; Li J; Goh J; Sekhar C; Cheong D; Tham KW
Build Environ; 2022 Nov; 225():109640. PubMed ID: 36210963
[TBL] [Abstract][Full Text] [Related]
15. Spread of SARS-CoV-2 aerosols via two connected drainage stacks in a high-rise housing outbreak of COVID-19.
Wang Q; Lin Z; Niu J; Choi GK; Fung JCH; Lau AKH; Louie P; Leung KKM; Huang J; Cheng P; Zhao P; Chen W; Zhang S; Fu L; Chan PW; Wong AH; Tse H; Wong SCY; Lai RWM; Hui DS; Yuen KY; Lung DC; Li Y
J Hazard Mater; 2022 May; 430():128475. PubMed ID: 35183827
[TBL] [Abstract][Full Text] [Related]
16. Probable Transmission of SARS-CoV-2 Omicron Variant in Quarantine Hotel, Hong Kong, China, November 2021.
Gu H; Krishnan P; Ng DYM; Chang LDJ; Liu GYZ; Cheng SSM; Hui MMY; Fan MCY; Wan JHL; Lau LHK; Cowling BJ; Peiris M; Poon LLM
Emerg Infect Dis; 2022 Feb; 28(2):460-462. PubMed ID: 34860154
[TBL] [Abstract][Full Text] [Related]
17. Effectiveness of portable air filtration on reducing indoor aerosol transmission: preclinical observational trials.
Lee JH; Rounds M; McGain F; Schofield R; Skidmore G; Wadlow I; Kevin K; Stevens A; Marshall C; Irving L; Kainer M; Buising K; Monty J
J Hosp Infect; 2022 Jan; 119():163-169. PubMed ID: 34562547
[TBL] [Abstract][Full Text] [Related]
18. Computational fluid dynamics study on the influence of an alternate ventilation configuration on the possible flow path of infectious cough aerosols in a mock airborne infection isolation room.
Thatiparti DS; Ghia U; Mead KR
Sci Technol Built Environ; 2016; 23(2):355-366. PubMed ID: 28736744
[TBL] [Abstract][Full Text] [Related]
19. Probable Evidence of Fecal Aerosol Transmission of SARS-CoV-2 in a High-Rise Building.
Kang M; Wei J; Yuan J; Guo J; Zhang Y; Hang J; Qu Y; Qian H; Zhuang Y; Chen X; Peng X; Shi T; Wang J; Wu J; Song T; He J; Li Y; Zhong N
Ann Intern Med; 2020 Dec; 173(12):974-980. PubMed ID: 32870707
[TBL] [Abstract][Full Text] [Related]
20. [Effect of a mobile room air filter on the aerosol burden in surgical examination rooms against the background of the COVID-19 pandemic].
Oberst M; Heinrich A
Unfallchirurg; 2021 May; 124(5):362-365. PubMed ID: 33638014
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]