These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

161 related articles for article (PubMed ID: 35162557)

  • 21. Risk estimation of the SARS-CoV-2 acute respiratory disease outbreak outside China.
    Kim S; Choi S; Ko Y; Ki M; Jung E
    Theor Biol Med Model; 2020 Jun; 17(1):9. PubMed ID: 32498721
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Probable Evidence of Fecal Aerosol Transmission of SARS-CoV-2 in a High-Rise Building.
    Kang M; Wei J; Yuan J; Guo J; Zhang Y; Hang J; Qu Y; Qian H; Zhuang Y; Chen X; Peng X; Shi T; Wang J; Wu J; Song T; He J; Li Y; Zhong N
    Ann Intern Med; 2020 Dec; 173(12):974-980. PubMed ID: 32870707
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Possible aerosol transmission of COVID-19 associated with an outbreak in an apartment in Seoul, South Korea, 2020.
    Hwang SE; Chang JH; Oh B; Heo J
    Int J Infect Dis; 2021 Mar; 104():73-76. PubMed ID: 33346125
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Air contamination with SARS-CoV-2 in the operating room.
    Hirota K
    J Anesth; 2021 Jun; 35(3):333-336. PubMed ID: 32562137
    [TBL] [Abstract][Full Text] [Related]  

  • 25. COVID-19 Cluster Linked to Aerosol Transmission of SARS-CoV-2 via Floor Drains.
    Han T; Park H; Jeong Y; Lee J; Shon E; Park MS; Sung M
    J Infect Dis; 2022 May; 225(9):1554-1560. PubMed ID: 35023551
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Air and Environmental Contamination Caused by COVID-19 Patients: a Multi-Center Study.
    Kim UJ; Lee SY; Lee JY; Lee A; Kim SE; Choi OJ; Lee JS; Kee SJ; Jang HC
    J Korean Med Sci; 2020 Sep; 35(37):e332. PubMed ID: 32959546
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Control of exhaled SARS-CoV-2-laden aerosols in the interpersonal breathing microenvironment in a ventilated room with limited space air stability.
    Deng X; Gong G; He X; Shi X; Mo L
    J Environ Sci (China); 2021 Oct; 108():175-187. PubMed ID: 34465431
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Bioaerosol Sampling for Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) in a Referral Center with Critically Ill Coronavirus Disease 2019 (COVID-19) Patients March-May 2020.
    Lane MA; Brownsword EA; Babiker A; Ingersoll JM; Waggoner J; Ayers M; Klopman M; Uyeki TM; Lindsley WG; Kraft CS
    Clin Infect Dis; 2021 Oct; 73(7):e1790-e1794. PubMed ID: 33506256
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Neglected Aspects of SARS-CoV-2 Aerosol Transmission in Bathrooms of Multistory and High-Rise Buildings - Beijing Municipality, China, October 2022.
    Lyu K; Wang Q; Li X; Zhang Z; Zhao X; Li Y; Tang Z; Li L; Deng F; Zhang X; Xu K; Zhao R; Xu D
    China CDC Wkly; 2023 Jan; 5(1):1-4. PubMed ID: 36777470
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Aerodynamic analysis of SARS-CoV-2 in two Wuhan hospitals.
    Liu Y; Ning Z; Chen Y; Guo M; Liu Y; Gali NK; Sun L; Duan Y; Cai J; Westerdahl D; Liu X; Xu K; Ho KF; Kan H; Fu Q; Lan K
    Nature; 2020 Jun; 582(7813):557-560. PubMed ID: 32340022
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Community evidence of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) transmission through air.
    Lin G; Zhang S; Zhong Y; Zhang L; Ai S; Li K; Su W; Cao L; Zhao Y; Tian F; Li J; Wu Y; Guo C; Peng R; Wu X; Gan P; Zhu W; Lin H; Zhang Z
    Atmos Environ (1994); 2021 Feb; 246():118083. PubMed ID: 33235537
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Air and environmental sampling for SARS-CoV-2 around hospitalized patients with coronavirus disease 2019 (COVID-19).
    Cheng VC; Wong SC; Chan VW; So SY; Chen JH; Yip CC; Chan KH; Chu H; Chung TW; Sridhar S; To KK; Chan JF; Hung IF; Ho PL; Yuen KY
    Infect Control Hosp Epidemiol; 2020 Nov; 41(11):1258-1265. PubMed ID: 32507114
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Viral aerosol transmission of SARS-CoV-2 from simulated human emission in a concert hall.
    Schade W; Reimer V; Seipenbusch M; Willer U; Hübner EG
    Int J Infect Dis; 2021 Jun; 107():12-14. PubMed ID: 33857608
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Lack of viable severe acute respiratory coronavirus virus 2 (SARS-CoV-2) among PCR-positive air samples from hospital rooms and community isolation facilities.
    Ong SWX; Tan YK; Coleman KK; Tan BH; Leo YS; Wang DL; Ng CG; Ng OT; Wong MSY; Marimuthu K
    Infect Control Hosp Epidemiol; 2021 Nov; 42(11):1327-1332. PubMed ID: 33487210
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Household secondary attack rate of COVID-19 and associated determinants in Guangzhou, China: a retrospective cohort study.
    Jing QL; Liu MJ; Zhang ZB; Fang LQ; Yuan J; Zhang AR; Dean NE; Luo L; Ma MM; Longini I; Kenah E; Lu Y; Ma Y; Jalali N; Yang ZC; Yang Y
    Lancet Infect Dis; 2020 Oct; 20(10):1141-1150. PubMed ID: 32562601
    [TBL] [Abstract][Full Text] [Related]  

  • 36. To prevent SARS-CoV-2 transmission in designated quarantine hotel for travelers: Is the ventilation system a concern?
    Wong SC; Chen H; Lung DC; Ho PL; Yuen KY; Cheng VC
    Indoor Air; 2021 Sep; 31(5):1295-1297. PubMed ID: 34259364
    [No Abstract]   [Full Text] [Related]  

  • 37. Efficacy of Portable Air Cleaners and Masking for Reducing Indoor Exposure to Simulated Exhaled SARS-CoV-2 Aerosols - United States, 2021.
    Lindsley WG; Derk RC; Coyle JP; Martin SB; Mead KR; Blachere FM; Beezhold DH; Brooks JT; Boots T; Noti JD
    MMWR Morb Mortal Wkly Rep; 2021 Jul; 70(27):972-976. PubMed ID: 34237047
    [TBL] [Abstract][Full Text] [Related]  

  • 38. [Ventilation concepts in schools for the prevention of transmission of highly infectious viruses (SARS-CoV-2) by aerosols in indoor air].
    Birmili W; Selinka HC; Moriske HJ; Daniels A; Straff W
    Bundesgesundheitsblatt Gesundheitsforschung Gesundheitsschutz; 2021 Dec; 64(12):1570-1580. PubMed ID: 34739549
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Efficacy of Ventilation, HEPA Air Cleaners, Universal Masking, and Physical Distancing for Reducing Exposure to Simulated Exhaled Aerosols in a Meeting Room.
    Coyle JP; Derk RC; Lindsley WG; Blachere FM; Boots T; Lemons AR; Martin SB; Mead KR; Fotta SA; Reynolds JS; McKinney WG; Sinsel EW; Beezhold DH; Noti JD
    Viruses; 2021 Dec; 13(12):. PubMed ID: 34960804
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Dose-response Relation Deduced for Coronaviruses From Coronavirus Disease 2019, Severe Acute Respiratory Syndrome, and Middle East Respiratory Syndrome: Meta-analysis Results and its Application for Infection Risk Assessment of Aerosol Transmission.
    Zhang X; Wang J
    Clin Infect Dis; 2021 Jul; 73(1):e241-e245. PubMed ID: 33119733
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.