BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

47 related articles for article (PubMed ID: 35168922)

  • 1. Customized orbital implant versus 3D preformed titanium mesh for orbital fracture repair: A retrospective comparative analysis of orbital reconstruction accuracy.
    Consorti G; Betti E; Catarzi L
    J Craniomaxillofac Surg; 2024 Apr; 52(4):532-537. PubMed ID: 38368208
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of patient specific implant reconstruction vs conventional titanium mesh reconstruction of orbital fractures using a novel method.
    Krasovsky A; Hija A; Zeineh N; Capucha T; Haze DA; Emodi O; Rachmiel A; Shilo D
    J Craniomaxillofac Surg; 2024 Apr; 52(4):491-502. PubMed ID: 38388230
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Presurgical Virtual Planning and Intraoperative Navigation with 3D-Preformed Mesh: A New Protocol for Primary Orbital Fracture Reconstruction.
    Consorti G; Monarchi G; Catarzi L
    Life (Basel); 2024 Apr; 14(4):. PubMed ID: 38672753
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Reconstruction of Total Maxillectomy Defects Using Coronoid-Temporalis Pedicled Flap, Titanium Mesh, and Free Flap.
    Liu W; Li C; Ma Z; Zhang G; Lubamba GP; Lian H; Zhang Z; Tang W
    Otolaryngol Head Neck Surg; 2024 Apr; 170(4):1200-1203. PubMed ID: 38104317
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Classical Orbital Floor Post-Traumatic Reconstruction vs. Customized Reconstruction with the Support of "In-House" 3D-Printed Models: A Retrospective Study with an Analysis of Volumetric Measurement.
    Kallaverja E; Barca I; Ferragina F; Cristofaro MG
    Diagnostics (Basel); 2024 Jun; 14(12):. PubMed ID: 38928663
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Delayed Orbital Floor Reconstruction Using Mirroring Technique and Patient-Specific Implants: Proof of Concept.
    D'Alpaos D; Badiali G; Ceccariglia F; Tarsitano A
    J Pers Med; 2024 Apr; 14(5):. PubMed ID: 38793041
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Intraoperative computed tomography for orbital reconstruction: a systematic review.
    Goh EZ; Bullis S; Beech N; Johnson NR
    Int J Oral Maxillofac Surg; 2024 Feb; 53(2):127-132. PubMed ID: 37208279
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Automated 3-D Computer-Aided Measurement of the Bony Orbit: Evaluation of Correlations among Volume, Depth, and Surface Area.
    Kontio R; Wilkman T; Mesimäki K; Chepurnyi Y; Asikainen A; Haapanen A; Poutala A; Mikkonen M; Slobodianiuk A; Kopchak A
    J Pers Med; 2024 May; 14(5):. PubMed ID: 38793092
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Image-guided navigation in posterior orbital tumour surgery: a comparative cohort study.
    Khan RI; Golahmadi AK; Killeen RP; O' Brien DF; Murphy C
    Orbit; 2024 Apr; ():1-10. PubMed ID: 38687963
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Pressure Cooker Nozzle Penetrated the Orbit - Globe Saved.
    Pore BB; Pore RB; Trivedi NV
    Asia Pac J Ophthalmol (Phila); 2021 Jul-Aug 01; 10(4):418-419. PubMed ID: 34415247
    [No Abstract]   [Full Text] [Related]  

  • 11. Computer-assisted planning, stereolithographic modeling, and intraoperative navigation for complex orbital reconstruction: a descriptive study in a preliminary cohort.
    Bell RB; Markiewicz MR
    J Oral Maxillofac Surg; 2009 Dec; 67(12):2559-70. PubMed ID: 19925972
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Does intraoperative navigation restore orbital dimensions in traumatic and post-ablative defects?
    Markiewicz MR; Dierks EJ; Bell RB
    J Craniomaxillofac Surg; 2012 Feb; 40(2):142-8. PubMed ID: 21493082
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Customised products for orbital wall reconstruction: a systematic review.
    Hartmann A; Kämmerer P; Ortolano LC; Sagheb K; Seiler M
    Br J Oral Maxillofac Surg; 2022 Jun; 60(5):e702-e711. PubMed ID: 35219519
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Advances in the Reconstruction of Orbital Fractures.
    Bevans SE; Moe KS
    Facial Plast Surg Clin North Am; 2017 Nov; 25(4):513-535. PubMed ID: 28941505
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Accuracy of globe-sparing orbital reconstruction using individually bent titanium mesh: A comparative study.
    Soh HY; Sun Q; Hu LH; Wang Y; Mao C; Peng X; Zhang WB
    J Plast Reconstr Aesthet Surg; 2022 Jun; 75(6):1971-1978. PubMed ID: 35168922
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Orbital floor symmetry after maxillectomy and orbital floor reconstruction with individual titanium mesh using computer-assisted navigation.
    Kang YF; Liang J; He Z; Zhang L; Shan XF; Cai ZG
    J Plast Reconstr Aesthet Surg; 2020 Feb; 73(2):337-343. PubMed ID: 31477492
    [TBL] [Abstract][Full Text] [Related]  

  • 17.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

  • 18.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

  • 19.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

  • 20.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 3.