These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
269 related articles for article (PubMed ID: 35171331)
1. Repeatability of a new swept-source optical coherence tomographer and agreement with other three optical biometers. Cheng SM; Zhang JS; Shao X; Wu ZT; Li TT; Wang P; Lin JH; Yu AY Graefes Arch Clin Exp Ophthalmol; 2022 Jul; 260(7):2271-2281. PubMed ID: 35171331 [TBL] [Abstract][Full Text] [Related]
2. Agreement between Two Swept-Source Optical Coherence Tomography Biometers and a Partial Coherence Interferometer. Moon JY; Cho SC; Kim HJ; Jun RM; Han KE Korean J Ophthalmol; 2022 Aug; 36(4):326-337. PubMed ID: 35766049 [TBL] [Abstract][Full Text] [Related]
3. Comparison of measurements and calculated lens power using three biometers: a Scheimpflug tomographer with partial coherence interferometry and two swept source optical coherence tomographers. Ang RET; Estolano BL; Luz PHC; Umali MIN; Araneta MMQ; Cruz EM BMC Ophthalmol; 2024 Sep; 24(1):410. PubMed ID: 39300358 [TBL] [Abstract][Full Text] [Related]
4. Comparison of ocular biometric measurements in patients with cataract using three swept-source optical coherence tomography devices. Oh R; Oh JY; Choi HJ; Kim MK; Yoon CH BMC Ophthalmol; 2021 Jan; 21(1):62. PubMed ID: 33504333 [TBL] [Abstract][Full Text] [Related]
5. Agreement between 2 swept-source OCT biometers and a Scheimpflug partial coherence interferometer. Tañá-Rivero P; Aguilar-Córcoles S; Tello-Elordi C; Pastor-Pascual F; Montés-Micó R J Cataract Refract Surg; 2021 Apr; 47(4):488-495. PubMed ID: 33252569 [TBL] [Abstract][Full Text] [Related]
6. Repeatability and agreement of ocular biometry measurements: Aladdin versus Lenstar. McAlinden C; Gao R; Yu A; Wang X; Yang J; Yu Y; Chen H; Wang Q; Huang J Br J Ophthalmol; 2017 Sep; 101(9):1223-1229. PubMed ID: 28130351 [TBL] [Abstract][Full Text] [Related]
7. Clinical comparison of a new swept-source optical coherence tomography-based optical biometer and a time-domain optical coherence tomography-based optical biometer. Srivannaboon S; Chirapapaisan C; Chonpimai P; Loket S J Cataract Refract Surg; 2015 Oct; 41(10):2224-32. PubMed ID: 26703299 [TBL] [Abstract][Full Text] [Related]
8. Repeatability of biometry measured by three devices and its impact on predicted intraocular lens power. Shetty N; Kaweri L; Koshy A; Shetty R; Nuijts RMMA; Sinha Roy A J Cataract Refract Surg; 2021 May; 47(5):585-592. PubMed ID: 33252565 [TBL] [Abstract][Full Text] [Related]
9. Comparative analysis of two optical biometry devices: high wavelength swept source OCT versus partial coherence interferometry. Szalai E; Csutak A Int Ophthalmol; 2022 Feb; 42(2):627-634. PubMed ID: 34633606 [TBL] [Abstract][Full Text] [Related]
10. Repeatability and comparability of a new swept-source optical coherence tomographer in optical biometry. Monera Lucas CE; Escolano Serrano J; Tarazona Jaimes C; Romero Valero D; Moya Martínez A; Martínez Toldos JJ Arch Soc Esp Oftalmol (Engl Ed); 2022 Dec; 97(12):670-675. PubMed ID: 36068133 [TBL] [Abstract][Full Text] [Related]
11. Comparison of refractive outcomes obtained with two swept-source OCT-based optical biometers after cataract surgery: A study of 152 eyes. Agard E; Levron A; Billant J; Douma I; Dot C J Fr Ophtalmol; 2024 Jun; 47(6):104186. PubMed ID: 38663226 [TBL] [Abstract][Full Text] [Related]
12. Repeatability and agreement of Scheimpflug-based and swept-source optical biometry measurements. Sel S; Stange J; Kaiser D; Kiraly L Cont Lens Anterior Eye; 2017 Oct; 40(5):318-322. PubMed ID: 28342729 [TBL] [Abstract][Full Text] [Related]
13. The repeatability and agreement of biometric measurements by dual Scheimpflug device with integrated optical biometer. Hashemi H; Sardari S; Yekta A; Khabazkhoob M Sci Rep; 2022 May; 12(1):7748. PubMed ID: 35546610 [TBL] [Abstract][Full Text] [Related]