These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

173 related articles for article (PubMed ID: 35174958)

  • 21. Retrieval study of commercially available knee implant coatings TiN, TiNbN and ZrN on TiAl6V4 and CoCr28Mo6.
    Herbster M; Döring J; Nohava J; Lohmann CH; Halle T; Bertrand J
    J Mech Behav Biomed Mater; 2020 Dec; 112():104034. PubMed ID: 32871541
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Potentiodynamic polarization study of the in vitro corrosion behavior of 3 high-palladium alloys and a gold-palladium alloy in 5 media.
    Sun D; Monaghan P; Brantley WA; Johnston WM
    J Prosthet Dent; 2002 Jan; 87(1):86-93. PubMed ID: 11807489
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Fretting corrosion in orthopaedic alloys.
    Cook SD; Gianoli GJ; Clemow AJ; Haddad RJ
    Biomater Med Devices Artif Organs; 1983-1984; 11(4):281-92. PubMed ID: 6679798
    [TBL] [Abstract][Full Text] [Related]  

  • 24. In vivo corrosion and damages in modular shoulder prostheses.
    Crackau M; Märtens N; Harnisch K; Berth A; Döring J; Lohmann CH; Halle T; Bertrand J
    J Biomed Mater Res B Appl Biomater; 2020 Jul; 108(5):1764-1778. PubMed ID: 31763747
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Corrosion behavior of cast and forged cobalt-based alloys for double-alloy joint endoprostheses.
    Süry P; Semlitsch M
    J Biomed Mater Res; 1978 Sep; 12(5):723-41. PubMed ID: 701305
    [TBL] [Abstract][Full Text] [Related]  

  • 26. The effect of porous coating processing on the corrosion behavior of cast Co-Cr-Mo surgical implant alloys.
    Jacobs JJ; Latanision RM; Rose RM; Veeck SJ
    J Orthop Res; 1990 Nov; 8(6):874-82. PubMed ID: 2213344
    [TBL] [Abstract][Full Text] [Related]  

  • 27. A new finding on the in-vivo crevice corrosion damage in a CoCrMo hip implant.
    Oskouei RH; Barati MR; Farhoudi H; Taylor M; Solomon LB
    Mater Sci Eng C Mater Biol Appl; 2017 Oct; 79():390-398. PubMed ID: 28629033
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Electrochemical corrosion of metallic biomaterials.
    Pourbaix M
    Biomaterials; 1984 May; 5(3):122-34. PubMed ID: 6375748
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Surface mechanical properties, corrosion resistance, and cytocompatibility of nitrogen plasma-implanted nickel-titanium alloys: a comparative study with commonly used medical grade materials.
    Yeung KW; Poon RW; Chu PK; Chung CY; Liu XY; Lu WW; Chan D; Chan SC; Luk KD; Cheung KM
    J Biomed Mater Res A; 2007 Aug; 82(2):403-14. PubMed ID: 17295246
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Fretting corrosion resistance and fretting corrosion product cytocompatibility of ferritic stainless steel.
    Xulin S; Ito A; Tateishi T; Hoshino A
    J Biomed Mater Res; 1997 Jan; 34(1):9-14. PubMed ID: 8978647
    [TBL] [Abstract][Full Text] [Related]  

  • 31. In vivo severe corrosion and hydrogen embrittlement of retrieved modular body titanium alloy hip-implants.
    Rodrigues DC; Urban RM; Jacobs JJ; Gilbert JL
    J Biomed Mater Res B Appl Biomater; 2009 Jan; 88(1):206-19. PubMed ID: 18683224
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Analysis of in vivo corrosion of 316L stainless steel posterior thoracolumbar plate systems: a retrieval study.
    Majid K; Crowder T; Baker E; Baker K; Koueiter D; Shields E; Herkowitz HN
    J Spinal Disord Tech; 2011 Dec; 24(8):500-5. PubMed ID: 21336173
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Elucidating the corrosion-related degradation mechanisms of a Ti-6Al-4V dental implant.
    Chen X; Shah K; Dong S; Peterson L; Callagon La Plante E; Sant G
    Dent Mater; 2020 Mar; 36(3):431-441. PubMed ID: 31992484
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Corrosion of nickel-based dental casting alloys.
    Wylie CM; Shelton RM; Fleming GJ; Davenport AJ
    Dent Mater; 2007 Jun; 23(6):714-23. PubMed ID: 16949144
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Mixed-metal fretting corrosion of Ti6Al4V and wrought cobalt alloy.
    Kawalec JS; Brown SA; Payer JH; Merritt K
    J Biomed Mater Res; 1995 Jul; 29(7):867-73. PubMed ID: 7593026
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Cast vs. wrought cobalt-chromium surgical implant alloys.
    Devine TM; Wulff J
    J Biomed Mater Res; 1975 Mar; 9(2):151-67. PubMed ID: 1176476
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Developing high strength and ductility in biomedical Co-Cr cast alloys by simultaneous doping with nitrogen and carbon.
    Yamanaka K; Mori M; Chiba A
    Acta Biomater; 2016 Feb; 31():435-447. PubMed ID: 26678827
    [TBL] [Abstract][Full Text] [Related]  

  • 38. In vivo corrosion of modular hip prosthesis components in mixed and similar metal combinations. The effect of crevice, stress, motion, and alloy coupling.
    Gilbert JL; Buckley CA; Jacobs JJ
    J Biomed Mater Res; 1993 Dec; 27(12):1533-44. PubMed ID: 8113241
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Microstructure, hardness, corrosion resistance and porcelain shear bond strength comparison between cast and hot pressed CoCrMo alloy for metal-ceramic dental restorations.
    Henriques B; Soares D; Silva FS
    J Mech Behav Biomed Mater; 2012 Aug; 12():83-92. PubMed ID: 22659369
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Special modes of corrosion under physiological and simulated physiological conditions.
    Virtanen S; Milosev I; Gomez-Barrena E; Trebse R; Salo J; Konttinen YT
    Acta Biomater; 2008 May; 4(3):468-76. PubMed ID: 18226986
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.