These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

150 related articles for article (PubMed ID: 35179750)

  • 1. Use of multiparametric magnetic resonance imaging as a screening tool for the determination of acute ischemic stroke duration.
    Taner Bulut H; Altun Y; Arik A; Oktay C; Çorapli M
    Eur Rev Med Pharmacol Sci; 2022 Feb; 26(3):846-852. PubMed ID: 35179750
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Diffusion-Weighted Imaging Fluid-Attenuated Inversion Recovery Mismatch on Portable, Low-Field Magnetic Resonance Imaging Among Acute Stroke Patients.
    Sorby-Adams A; Guo J; de Havenon A; Payabvash S; Sze G; Pinter NK; Jaikumar V; Siddiqui A; Baldassano S; Garcia-Guarniz AL; Zabinska J; Lalwani D; Peasley E; Goldstein JN; Nelson OK; Schaefer PW; Wira CR; Pitts J; Lee V; Muir KW; Nimjee SM; Kirsch J; Iglesias JE; Rosen MS; Sheth KN; Kimberly WT
    Ann Neurol; 2024 Aug; 96(2):321-331. PubMed ID: 38738750
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The Effects of DWI-Infarct Lesion Volume on DWI-FLAIR Mismatch: Is There a Need for Size Stratification?
    Payabvash S; Taleb S; Benson JC; Rykken JB; Oswood MC; McKinney AM; Hoffman B
    J Neuroimaging; 2017 Jul; 27(4):392-396. PubMed ID: 27878926
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Diffusion-Weighted Imaging and Fluid-Attenuated Inversion Recovery Quantification to Predict Diffusion-Weighted Imaging-Fluid-Attenuated Inversion Recovery Mismatch Status in Ischemic Stroke With Unknown Onset.
    Scheldeman L; Wouters A; Dupont P; Christensen S; Boutitie F; Cheng B; Ebinger M; Endres M; Fiebach JB; Gerloff C; Muir KW; Nighoghossian N; Pedraza S; Simonsen CZ; Thijs V; Thomalla G; Lemmens R
    Stroke; 2022 May; 53(5):1665-1673. PubMed ID: 35105179
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Negative fluid-attenuated inversion recovery imaging identifies acute ischemic stroke at 3 hours or less.
    Thomalla G; Rossbach P; Rosenkranz M; Siemonsen S; Krützelmann A; Fiehler J; Gerloff C
    Ann Neurol; 2009 Jun; 65(6):724-32. PubMed ID: 19557859
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Can diffusion-weighted imaging-fluid-attenuated inversion recovery mismatch (positive diffusion-weighted imaging/negative fluid-attenuated inversion recovery) at 3 Tesla identify patients with stroke at <4.5 hours?
    Emeriau S; Serre I; Toubas O; Pombourcq F; Oppenheim C; Pierot L
    Stroke; 2013 Jun; 44(6):1647-51. PubMed ID: 23640823
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Synthetic FLAIR as a Substitute for FLAIR Sequence in Acute Ischemic Stroke.
    Benzakoun J; Deslys MA; Legrand L; Hmeydia G; Turc G; Hassen WB; Charron S; Debacker C; Naggara O; Baron JC; Thirion B; Oppenheim C
    Radiology; 2022 Apr; 303(1):153-159. PubMed ID: 35014901
    [TBL] [Abstract][Full Text] [Related]  

  • 8. DWI-FLAIR mismatch for the identification of patients with acute ischaemic stroke within 4·5 h of symptom onset (PRE-FLAIR): a multicentre observational study.
    Thomalla G; Cheng B; Ebinger M; Hao Q; Tourdias T; Wu O; Kim JS; Breuer L; Singer OC; Warach S; Christensen S; Treszl A; Forkert ND; Galinovic I; Rosenkranz M; Engelhorn T; Köhrmann M; Endres M; Kang DW; Dousset V; Sorensen AG; Liebeskind DS; Fiebach JB; Fiehler J; Gerloff C;
    Lancet Neurol; 2011 Nov; 10(11):978-86. PubMed ID: 21978972
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Quantitative measurements of relative fluid-attenuated inversion recovery (FLAIR) signal intensities in acute stroke for the prediction of time from symptom onset.
    Cheng B; Brinkmann M; Forkert ND; Treszl A; Ebinger M; Köhrmann M; Wu O; Kang DW; Liebeskind DS; Tourdias T; Singer OC; Christensen S; Luby M; Warach S; Fiehler J; Fiebach JB; Gerloff C; Thomalla G;
    J Cereb Blood Flow Metab; 2013 Jan; 33(1):76-84. PubMed ID: 23047272
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Diffusion-weighted imaging-fluid attenuated inversion recovery mismatch in nocturnal stroke patients with unknown time of onset.
    Huisa BN; Liebeskind DS; Raman R; Hao Q; Meyer BC; Meyer DM; Hemmen TM;
    J Stroke Cerebrovasc Dis; 2013 Oct; 22(7):972-7. PubMed ID: 22325574
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Lesion Age Imaging in Acute Stroke: Water Uptake in CT Versus DWI-FLAIR Mismatch.
    Broocks G; Leischner H; Hanning U; Flottmann F; Faizy TD; Schön G; Sporns P; Thomalla G; Kamalian S; Lev MH; Fiehler J; Kemmling A
    Ann Neurol; 2020 Dec; 88(6):1144-1152. PubMed ID: 32939824
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Diffusion-Weighted Imaging-Fluid-Attenuated Inversion Recovery Mismatch Is Associated with 90-Day Functional Outcomes in Patients Undergoing Mechanical Thrombectomy.
    Sakakibara F; Yoshimura S; Numa S; Uchida K; Kinjo N; Morimoto T
    Cerebrovasc Dis; 2020; 49(3):292-300. PubMed ID: 32544919
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Prediction of Stroke Onset Is Improved by Relative Fluid-Attenuated Inversion Recovery and Perfusion Imaging Compared to the Visual Diffusion-Weighted Imaging/Fluid-Attenuated Inversion Recovery Mismatch.
    Wouters A; Dupont P; Norrving B; Laage R; Thomalla G; Albers GW; Thijs V; Lemmens R
    Stroke; 2016 Oct; 47(10):2559-64. PubMed ID: 27601375
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Clinical characteristics of unknown symptom onset stroke patients with and without diffusion-weighted imaging and fluid-attenuated inversion recovery mismatch.
    Thomalla G; Boutitie F; Fiebach JB; Simonsen CZ; Pedraza S; Lemmens R; Nighoghossian N; Roy P; Muir KW; Ebinger M; Ford I; Cheng B; Galinovic I; Cho TH; Puig J; Thijs V; Endres M; Fiehler J; Gerloff C
    Int J Stroke; 2018 Jan; 13(1):66-73. PubMed ID: 28425349
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A pragmatic approach using magnetic resonance imaging to treat ischemic strokes of unknown onset time in a thrombolytic trial.
    Song SS; Latour LL; Ritter CH; Wu O; Tighiouart M; Hernandez DA; Ku KD; Luby M; Warach S
    Stroke; 2012 Sep; 43(9):2331-5. PubMed ID: 22693129
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The Role of the Signal Intensity Ratio on Fluid-Attenuated Inversion Recovery in Stroke Patients Achieving Successful Recanalization with Endovascular Treatment.
    Kim T; Chung JW; Jang MS; Yang MH; Lee SH; Kim BJ; Han MK; Kim JH; Jung C; Lim JS; Bae HJ
    J Stroke Cerebrovasc Dis; 2017 Jul; 26(7):1528-1534. PubMed ID: 28342654
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Diffusion-weighted image and fluid-attenuated inversion recovery image mismatch: unclear-onset versus clear-onset stroke.
    Kim BJ; Kim HJ; Lee DH; Kwon SU; Kim SJ; Kim JS; Kang DW
    Stroke; 2014 Feb; 45(2):450-5. PubMed ID: 24347423
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Fluid-Attenuated Inversion Recovery (FLAIR) Signal Intensity Can Identify Stroke Within 6 and 8 Hours.
    Legge J; Graham A; Male S; Copeland D; Lee R; Goyal N; Zand R
    J Stroke Cerebrovasc Dis; 2017 Jul; 26(7):1582-1587. PubMed ID: 28359617
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Difficulty of MRI based identification of lesion age by acute infra-tentorial ischemic stroke.
    Grosse-Dresselhaus F; Galinovic I; Villringer K; Audebert HJ; Fiebach JB
    PLoS One; 2014; 9(3):e92868. PubMed ID: 24651570
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Collateral circulation assessment within the 4.5 h time window in patients with and without DWI/FLAIR MRI mismatch.
    Berthezène Y; Eker O; Makris N; Bettan M; Mansuy A; Chabrol A; Mikkelsenm IK; Hermier M; Mechtouff L; Ong E; Derex L; Berner LP; Ameli R; Pedraza S; Thomalla G; Østergaard L; Baron JC; Cho TH; Nighoghossian N
    J Neurol Sci; 2018 Nov; 394():94-98. PubMed ID: 30240943
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.