These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

112 related articles for article (PubMed ID: 35179823)

  • 21. Thermoforming technique for suppressing reduction in mouthguard thickness: Part 2 Effect of model height and model moving distance.
    Takahashi M; Bando Y
    Dent Traumatol; 2020 Oct; 36(5):543-550. PubMed ID: 32170787
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Prioritizing model trimming to prevent thinning during mouthguard thermoforming: Influence of increased height associated with an acute model angle.
    Takahashi M; Bando Y
    Dent Traumatol; 2023 Feb; 39(1):11-18. PubMed ID: 36251443
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Method for effectively maintaining the thickness of mouthguards fabricated using EVA sheets and a circle tray: influence of grooved sheet and heating conditions.
    Takahashi M; Koide K; Iwasaki S
    Dent Traumatol; 2016 Jun; 32(3):206-11. PubMed ID: 26446254
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Movement of model position just before vacuum forming to ensure mouthguard thickness: Part 2 Effect of model moving distance.
    Takahashi M; Bando Y
    Dent Traumatol; 2019 Oct; 35(4-5):291-295. PubMed ID: 31220414
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Differences in the thickness of mouthguards fabricated from ethylene vinyl acetate copolymer sheets with differently arranged v-shaped grooves: part 2 - effect of shape on the working model.
    Takahashi M; Koide K; Mizuhashi F
    Dent Traumatol; 2014 Dec; 30(6):472-6. PubMed ID: 25039583
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Difference in pressure-formed mouthguard thickness according to heating condition.
    Mizuhashi F; Koide K; Takahashi M
    Dent Traumatol; 2016 Feb; 32(1):22-6. PubMed ID: 26177444
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Thickness of mouthguard sheets after vacuum-pressure formation: influence of mouthguard sheet material.
    Takahashi M; Koide K; Iwasaki S
    Dent Traumatol; 2016 Jun; 32(3):201-5. PubMed ID: 26446242
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Effect of the anteroposterior position of the model on fabricated mouthguard thickness: Part 2 Influence of sheet thickness and material.
    Takahashi M; Bando Y
    Dent Traumatol; 2018 Oct; 34(5):370-377. PubMed ID: 29932508
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Variations in mouthguard thickness according to fabrication method.
    Mizuhashi F; Koide K; Takahashi M
    Dent Traumatol; 2015 Apr; 31(2):130-5. PubMed ID: 25279665
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Forming temperature of ethylene vinyl acetate sheets for fabrication of vacuum-formed mouthguards.
    Mizuhashi R; Ogura I; Sugawara Y; Oohashi M; Sekiguchi H; Saegusa H; Mizuhashi F
    Dent Traumatol; 2020 Oct; 36(5):538-542. PubMed ID: 32034882
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Appropriate fabrication method for vacuum-formed mouthguards.
    Mizuhashi F; Koide K
    Dent Traumatol; 2017 Apr; 33(2):110-113. PubMed ID: 27500893
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Difference in the thickness of mouthguards fabricated from ethylene-vinyl acetate co-polymer sheets with differently arranged v-shaped grooves.
    Takahashi M; Koide K; Mizuhashi F
    J Prosthodont Res; 2013 Jul; 57(3):169-78. PubMed ID: 23623048
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Appropriate fabrication method for pressure-formed mouthguards using polyolefin sheets.
    Watarai Y; Mizuhashi F; Koide K
    Dent Traumatol; 2022 Apr; 38(2):149-155. PubMed ID: 34897969
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Optimal heating conditions for forming a mouthguard using a circle tray: effect of different conditions on the thickness and fit of formed mouthguards.
    Takahashi M; Koide K; Mizuhashi F
    J Prosthodont Res; 2014 Jul; 58(3):171-6. PubMed ID: 24780307
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Difference in vacuum-formed mouthguard thickness according to timing of vacuum application.
    Mizuhashi F; Koide K; Takahashi M
    Dent Traumatol; 2016 Aug; 32(4):306-10. PubMed ID: 26542181
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Appropriate fabrication method for vacuum-formed mouthguards using polyolefin sheets.
    Mizuhashi F; Koide K
    Dent Traumatol; 2020 Aug; 36(4):433-437. PubMed ID: 31957976
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Formation of vacuum-formed and pressure-formed mouthguards.
    Mizuhashi F; Koide K
    Dent Traumatol; 2017 Aug; 33(4):295-299. PubMed ID: 28301714
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Influence of sheet material shape on the thickness and fit of mouthguards.
    Takahashi M; Koide K; Mizuhashi F
    Dent Traumatol; 2014 Dec; 30(6):455-60. PubMed ID: 24720352
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Shape change in mouthguard sheets during thermoforming.
    Takahashi M; Koide K; Satoh Y; Iwasaki S
    Dent Traumatol; 2016 Oct; 32(5):379-84. PubMed ID: 26833572
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Vacuum-formed mouthguard fabrication to obtain proper fit using notched sheet.
    Mizuhashi F; Koide K
    Dent Traumatol; 2019 Jun; 35(3):204-211. PubMed ID: 30633853
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.