These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

257 related articles for article (PubMed ID: 35182171)

  • 41. Low wear rates seen in THAs with highly crosslinked polyethylene at 9 to 14 years in patients younger than age 50 years.
    Garvin KL; White TC; Dusad A; Hartman CW; Martell J
    Clin Orthop Relat Res; 2015 Dec; 473(12):3829-35. PubMed ID: 26122983
    [TBL] [Abstract][Full Text] [Related]  

  • 42. The rates of osteolysis and loosening associated with a modular posterior stabilized knee replacement. Results at five to fourteen years.
    Lachiewicz PF; Soileau ES
    J Bone Joint Surg Am; 2004 Mar; 86(3):525-30. PubMed ID: 14996878
    [TBL] [Abstract][Full Text] [Related]  

  • 43. All-polyethylene versus metal-backed tibial component in total knee arthroplasty.
    Longo UG; Ciuffreda M; D'Andrea V; Mannering N; Locher J; Denaro V
    Knee Surg Sports Traumatol Arthrosc; 2017 Nov; 25(11):3620-3636. PubMed ID: 27209191
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Reduced wear in vitamin E-infused highly cross-linked polyethylene cups: 5-year results of a randomized controlled trial.
    Rochcongar G; Remazeilles M; Bourroux E; Dunet J; Chapus V; Feron M; Praz C; Buia G; Hulet C
    Acta Orthop; 2021 Apr; 92(2):151-155. PubMed ID: 33263447
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Vitamin E-enriched polyethylene bearings are not inferior to Arcom bearings in primary total knee arthroplasty at medium-term follow-up.
    Ftaita S; Vanden Berghe A; Thienpont E
    Arch Orthop Trauma Surg; 2021 Jun; 141(6):1027-1033. PubMed ID: 33417026
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Ultra-High-Molecular-Weight Polyethylene in Hip and Knee Arthroplasties.
    Hasegawa M; Tone S; Naito Y; Sudo A
    Materials (Basel); 2023 Mar; 16(6):. PubMed ID: 36984020
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Medium-term osteolysis with the Wallaby I® deep-dished total knee prosthesis.
    Marion B; Huten D; Boyer P; Jeanrot C; Massin P
    Orthop Traumatol Surg Res; 2014 Jun; 100(4):403-8. PubMed ID: 24794498
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Retention versus sacrifice of the posterior cruciate ligament in total knee arthroplasty for treating osteoarthritis.
    Verra WC; van den Boom LG; Jacobs W; Clement DJ; Wymenga AA; Nelissen RG
    Cochrane Database Syst Rev; 2013 Oct; 2013(10):CD004803. PubMed ID: 24114343
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Long-Term Assessment of Highly Cross-Linked and Compression-Molded Polyethylene Inserts for Posterior Cruciate-Substituting TKA in Young Patients: A Concise Follow-up of a Previous Report.
    Kim YH; Park JW
    J Bone Joint Surg Am; 2020 Sep; 102(18):1623-1627. PubMed ID: 32590398
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Prospective randomized trial of standard
    Lachiewicz PF; O'Dell JA
    Bone Joint J; 2019 Jul; 101-B(7_Supple_C):33-39. PubMed ID: 31256647
    [TBL] [Abstract][Full Text] [Related]  

  • 51. 2-year results of an RCT of 2 uncemented isoelastic monoblock acetabular components: lower wear rate with vitamin E blended highly cross-linked polyethylene compared to ultra-high molecular weight polyethylene.
    van Erp JHJ; Massier JRA; Halma JJ; Snijders TE; de Gast A
    Acta Orthop; 2020 Jun; 91(3):254-259. PubMed ID: 32098534
    [No Abstract]   [Full Text] [Related]  

  • 52. Computer-Navigated versus Conventional Total Knee Arthroplasty: A Meta-Analysis of Functional Outcomes from Level I and II Randomized Controlled Trials.
    Chin BZ; Seck VMH; Syn NL; Wee IJY; Tan SSH; O'Neill GK
    J Knee Surg; 2021 May; 34(6):648-658. PubMed ID: 31683347
    [TBL] [Abstract][Full Text] [Related]  

  • 53. A vitamin E blended highly cross-linked polyethylene acetabular cup results in less wear: 6-year results of a randomized controlled trial in 199 patients.
    Massier JRA; Van Erp JHJ; Snijders TE; Gast A
    Acta Orthop; 2020 Dec; 91(6):705-710. PubMed ID: 32835560
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Robotic-assisted mechanically aligned total knee arthroplasty does not lead to better clinical and radiological outcomes when compared to conventional TKA: a systematic review and meta-analysis of randomized controlled trials.
    Bensa A; Sangiorgio A; Deabate L; Illuminati A; Pompa B; Filardo G
    Knee Surg Sports Traumatol Arthrosc; 2023 Nov; 31(11):4680-4691. PubMed ID: 37270464
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Better outcomes are associated with cementless fixation in primary total knee arthroplasty in young patients: A systematic review and meta-analysis of randomized controlled trials.
    Wang K; Sun H; Zhang K; Li S; Wu G; Zhou J; Sun X
    Medicine (Baltimore); 2020 Jan; 99(3):e18750. PubMed ID: 32011458
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Creep and Wear in Vitamin E-Infused Highly Cross-Linked Polyethylene Cups for Total Hip Arthroplasty: A Prospective Randomized Controlled Trial.
    Rochcongar G; Buia G; Bourroux E; Dunet J; Chapus V; Hulet C
    J Bone Joint Surg Am; 2018 Jan; 100(2):107-114. PubMed ID: 29342060
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Does vitamin E-blended polyethylene reduce wear in primary total hip arthroplasty: a blinded randomised clinical trial.
    Scemama C; Anract P; Dumaine V; Babinet A; Courpied JP; Hamadouche M
    Int Orthop; 2017 Jun; 41(6):1113-1118. PubMed ID: 27815591
    [TBL] [Abstract][Full Text] [Related]  

  • 58. No difference in implant survivorship and clinical outcomes between full-cementless and full-cemented fixation in primary total knee arthroplasty: A systematic review and meta-analysis.
    Zhou K; Yu H; Li J; Wang H; Zhou Z; Pei F
    Int J Surg; 2018 May; 53():312-319. PubMed ID: 29656129
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Mobile-bearing versus fixed-bearing total knee arthroplasty: a meta-analysis of randomized controlled trials.
    Hantouly AT; Ahmed AF; Alzobi O; Toubasi A; Salameh M; Elmhiregh A; Hameed S; Ahmed GO; Alvand A; Al Dosari MAA
    Eur J Orthop Surg Traumatol; 2022 Apr; 32(3):481-495. PubMed ID: 34021791
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Is Cross-Linked Polyethylene an Improvement Over Conventional Ultra-High Molecular Weight Polyethylene in Total Knee Arthroplasty?
    Boyer B; Bordini B; Caputo D; Neri T; Stea S; Toni A
    J Arthroplasty; 2018 Mar; 33(3):908-914. PubMed ID: 29089224
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 13.