These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

133 related articles for article (PubMed ID: 35192022)

  • 1. Evaluation of the post-processing algorithms SimGrid and S-Enhance for paediatric intensive care patients and neonates.
    Krueger PC; Ebeling K; Waginger M; Glutig K; Scheithauer M; Schlattmann P; Proquitté H; Mentzel HJ
    Pediatr Radiol; 2022 May; 52(6):1029-1037. PubMed ID: 35192022
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The Potential Role of Grid-Like Software in Bedside Chest Radiography in Improving Image Quality and Dose Reduction: An Observer Preference Study.
    Ahn SY; Chae KJ; Goo JM
    Korean J Radiol; 2018; 19(3):526-533. PubMed ID: 29713231
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Multiscale image processing and antiscatter grids in digital radiography.
    Lo WY; Hornof WJ; Zwingenberger AL; Robertson ID
    Vet Radiol Ultrasound; 2009; 50(6):569-76. PubMed ID: 19999338
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparative study between mobile computed radiography and mobile flat-panel radiography for bedside chest radiography: impact of an antiscatter grid on the visibility of selected diagnostically relevant structures.
    Lehnert T; Naguib NN; Wutzler S; Bauer RW; Kerl JM; Burkhard T; Schulz B; Larson MC; Ackermann H; Vogl TJ; Balzer JO
    Invest Radiol; 2014 Jan; 49(1):1-6. PubMed ID: 24019019
    [TBL] [Abstract][Full Text] [Related]  

  • 5. CAN SCATTER CORRECTION SOFTWARE REPLACE A GRID IN DR PELVIC EXAMINATIONS?
    Precht H; Mørup SD; Tingberg A; Outzen CB; Kusk KW; Nielsen RM; Midtgård M; Winther MB; Waaler D; Kusk MW
    Radiat Prot Dosimetry; 2019 Dec; 187(1):8-16. PubMed ID: 31111927
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of Virtual Grid Processed Clinical Chest Radiographs.
    Gossye T; Buytaert D; Smeets PV; Morbée L; De Wilde C; Vermeiren K; Achten E; Bacher K
    Invest Radiol; 2022 Sep; 57(9):585-591. PubMed ID: 35438670
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Feasibility study of a novel portable digital radiography system modified for fluoroscopy in the neonatal intensive care unit.
    Liszewski MC; Richard S; Gross JN; Schonberger A; Levin TL; Blumfield E; Nafday SM; Taragin BH
    Pediatr Radiol; 2021 Aug; 51(9):1667-1675. PubMed ID: 33738539
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Investigating the use of an antiscatter grid in chest radiography for average adults with a computed radiography imaging system.
    Moore CS; Wood TJ; Avery G; Balcam S; Needler L; Smith A; Saunderson JR; Beavis AW
    Br J Radiol; 2015 Mar; 88(1047):20140613. PubMed ID: 25571914
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Reduced radiation dose and improved image quality using a mini mobile digital imaging system in a neonatal intensive care unit.
    Kim TH; Ryu JH; Jeong CW; Jun HY; Heo DW; Lee SH; Oh YK; Lee MJ; Yoon KH
    Clin Imaging; 2017; 42():165-171. PubMed ID: 28064140
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Improved image quality of cone beam CT scans for radiotherapy image guidance using fiber-interspaced antiscatter grid.
    Stankovic U; van Herk M; Ploeger LS; Sonke JJ
    Med Phys; 2014 Jun; 41(6):061910. PubMed ID: 24877821
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Scatter compensation for digital chest radiography using maximum likelihood expectation maximization.
    Floyd CE; Baydush AH; Lo JY; Bowsher JE; Ravin CE
    Invest Radiol; 1993 May; 28(5):427-33. PubMed ID: 8496036
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Impact of Software Parameter Settings on Image Quality of Virtual Grid Processed Radiography Images: A Contrast-Detail Phantom Study.
    Gossye T; Smeets PV; Achten E; Bacher K
    Invest Radiol; 2020 Jun; 55(6):374-380. PubMed ID: 31985603
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Improved image quality in digital mammography with image processing.
    Baydush AH; Floyd CE
    Med Phys; 2000 Jul; 27(7):1503-8. PubMed ID: 10947253
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of the image quality and dose reduction in digital radiography with an advanced spatial noise reduction algorithm in pediatric patients.
    Oh S; Kim JH; Yoo SY; Jeon TY; Kim YJ
    Eur Radiol; 2021 Dec; 31(12):8937-8946. PubMed ID: 34041570
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Development of Quality-Controlled Low-Dose Protocols for Radiography in the Neonatal ICU Using a New Mobile Digital Radiography System.
    Choi G; Cheon JE; Lee S; Choi YH; Shin SH; Cho YJ; Park SW
    AJR Am J Roentgenol; 2020 Aug; 215(2):488-493. PubMed ID: 32406770
    [No Abstract]   [Full Text] [Related]  

  • 16. Dose reduction in thorax radiography in simulated neonates with additional filtration and digital luminescence radiography.
    Seifert H; Jesberger HJ; Schneider G; Rein L; Blass G; Limbach HG; Niewald M; Sitzmann FC; Kramann B
    Acta Radiol; 1998 Sep; 39(5):514-9. PubMed ID: 9755700
    [TBL] [Abstract][Full Text] [Related]  

  • 17. ITERATIVE SCATTER CORRECTION FOR GRID-LESS BEDSIDE CHEST RADIOGRAPHY: PERFORMANCE FOR A CHEST PHANTOM.
    Mentrup D; Jockel S; Menser B; Neitzel U
    Radiat Prot Dosimetry; 2016 Jun; 169(1-4):308-12. PubMed ID: 26487750
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Improvement of image quality applying iterative scatter correction for grid-less skeletal radiography in trauma room setting.
    Lisson CG; Lisson CS; Vogele D; Strauss B; Schuetze K; Cintean R; Beer M; Schmidt SA
    Acta Radiol; 2020 Jun; 61(6):768-775. PubMed ID: 31569948
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of scatter rejection and low-contrast performance of scan equalization digital radiography (SEDR), slot-scan digital radiography, and full-field digital radiography systems for chest phantom imaging.
    Liu X; Shaw CC; Lai CJ; Wang T
    Med Phys; 2011 Jan; 38(1):23-33. PubMed ID: 21361171
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of Virtual Grid processed clinical pelvic radiographs.
    Gossye T; Buytaert D; Smeets PV; Morbée L; Vereecke E; Kellens PJ; Achten E; Bacher K
    J Appl Clin Med Phys; 2024 Jun; 25(6):e14353. PubMed ID: 38693646
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.