These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
104 related articles for article (PubMed ID: 3521029)
1. Influence of spectral broadening on continuous wave Doppler ultrasound spectra: a geometric approach. Bascom PA; Cobbold RS; Roelofs BH Ultrasound Med Biol; 1986 May; 12(5):387-95. PubMed ID: 3521029 [TBL] [Abstract][Full Text] [Related]
2. [Causes and influential factors of spectral broadening in Doppler flow signal]. Wen Y; Qian M; Gong X; Zhen B; Wan M Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 1997 Jun; 14(2):118-23. PubMed ID: 9817638 [TBL] [Abstract][Full Text] [Related]
3. Spectral power density calculations for pulsed Doppler. Thompson RS; Aldis GK Ultrasonics; 2002 Oct; 39(10):703-14. PubMed ID: 12479602 [TBL] [Abstract][Full Text] [Related]
4. Effects of transducer beam geometry and flow velocity profile on the Doppler power spectrum: a theoretical study. Bascom PA; Cobbold RS Ultrasound Med Biol; 1990; 16(3):279-95. PubMed ID: 2194337 [TBL] [Abstract][Full Text] [Related]
5. Modeling of Doppler signal considering sample volume and field distribution. Kim YM; Park SB Ultrason Imaging; 1989 Jul; 11(3):175-96. PubMed ID: 2675451 [TBL] [Abstract][Full Text] [Related]
7. Factors affecting the continuous wave Doppler spectrum for the diagnosis of carotid arterial disease. Morin JF; Johnston KW; Law YF Ultrasound Med Biol; 1988; 14(3):175-89. PubMed ID: 3289222 [TBL] [Abstract][Full Text] [Related]
8. 2-D tracking Doppler: a new method to limit spectral broadening in pulsed wave Doppler. Fredriksen TD; Ekroll IK; Lovstakken L; Torp H IEEE Trans Ultrason Ferroelectr Freq Control; 2013 Sep; 60(9):1896-905. PubMed ID: 24658720 [TBL] [Abstract][Full Text] [Related]
9. In vitro study of continuous wave Doppler spectral changes resulting from stenoses and bulbs. Morin JF; Johnston KW; Law YF Ultrasound Med Biol; 1987 Jan; 13(1):5-13. PubMed ID: 3551271 [TBL] [Abstract][Full Text] [Related]
10. Measurement of blood perfusion in tissue using Doppler ultrasound. Dymling SO; Persson HW; Hertz CH Ultrasound Med Biol; 1991; 17(5):433-44. PubMed ID: 1835810 [TBL] [Abstract][Full Text] [Related]
11. Imaging the carotid bifurcation using continuous-wave Doppler-shift ultrasound and spectral analysis. Lewis RR; Beasley MG; Hyams DE; Gosling RG Stroke; 1978; 9(5):465-71. PubMed ID: 705828 [TBL] [Abstract][Full Text] [Related]