133 related articles for article (PubMed ID: 3521944)
1. An optimized method for measuring cyclosporin A with 125I-labeled cyclosporin.
Felder RA; Mifflin TE; Bastani B
Clin Chem; 1986 Jul; 32(7):1378-82. PubMed ID: 3521944
[TBL] [Abstract][Full Text] [Related]
2. Comparison of cyclosporine determinations in whole blood by three different methods. HPLC, 125I RIA and 3H RIA.
Huang WY; Lipsey AI; Cheng MH
Am J Clin Pathol; 1987 Apr; 87(4):528-32. PubMed ID: 3826016
[TBL] [Abstract][Full Text] [Related]
3. Measurement of cyclosporine concentrations in whole blood: HPLC and radioimmunoassay with a specific monoclonal antibody and 3H- or 125I-labeled ligand compared.
Wolf BA; Daft MC; Koenig JW; Flye MW; Turk JW; Scott MG
Clin Chem; 1989 Jan; 35(1):120-4. PubMed ID: 2642760
[TBL] [Abstract][Full Text] [Related]
4. Simple, rapid 125I-labeled cyclosporine double antibody/polyethylene glycol radioimmunoassay used in a pediatric cardiac transplant program.
Berk LS; Webb G; Imperio NC; Nehlsen-Cannarella SL; Eby WC
Ther Drug Monit; 1986; 8(4):469-73. PubMed ID: 3547782
[TBL] [Abstract][Full Text] [Related]
5. Substitution of 125I-labeled cyclosporine in the radioimmunoassay of plasma cyclosporine.
McBride JH; Rodgerson DO; Allin RE; Ota MK
Transplantation; 1988 Feb; 45(2):495-7. PubMed ID: 3344550
[No Abstract] [Full Text] [Related]
6. Calibration problems with the 125I immunoassay for measuring cyclosporin A.
Copeland KR; Yatscoff RW
Clin Chem; 1989 Jul; 35(7):1551-2. PubMed ID: 2758614
[No Abstract] [Full Text] [Related]
7. Evaluation of the Incstar Cyclo-Trac sp kit for the determination of cyclosporine in blood.
Plebani M; Masiero M; Paleari CD; Faggian D; Burlina A
Clin Biochem; 1989 Oct; 22(5):345-7. PubMed ID: 2805337
[TBL] [Abstract][Full Text] [Related]
8. Derivatives of cyclosporin compatible with antibody-based assays: I. The generation of [125I]-labeled cyclosporin.
Mahoney WC; Orf JW
Clin Chem; 1985 Mar; 31(3):459-62. PubMed ID: 3971569
[TBL] [Abstract][Full Text] [Related]
9. An explanation of the noncorrespondence between assessment methods of cyclosporin.
Randleff-Rasmussen GM; Oosthuizen MM; Myburgh JA
Transpl Int; 1989 Dec; 2(4):181-6. PubMed ID: 2627259
[TBL] [Abstract][Full Text] [Related]
10. Measurement of cyclosporine in plasma from patients with various transplants: HPLC radioimmunoassay with a specific monoclonal antibody compared.
McBride JH; Rodgerson DO; Park SS; Reyes AF
Clin Chem; 1989 Aug; 35(8):1726-30. PubMed ID: 2667807
[TBL] [Abstract][Full Text] [Related]
11. Comparison of cyclosporin A measurement in whole blood by six different methods.
Tjandra-Maga B; Verbesselt R; Scharpé S; Verkerk R; Lambert WE; Van Liedekerke B; De Leenheer A
J Clin Chem Clin Biochem; 1990 Jan; 28(1):53-7. PubMed ID: 2313238
[TBL] [Abstract][Full Text] [Related]
12. Therapeutic monitoring of cyclosporine: impact of a change in standards on 125I-monoclonal RIA performance in comparison with liquid chromatography.
Keown PA; Glenn J; Denegri J; Maciejewska U; Seccombe D; Stawecki M; Freeman D; Stiller C; Shackleton C; Cameron E
Clin Chem; 1990 May; 36(5):804-7. PubMed ID: 2337993
[TBL] [Abstract][Full Text] [Related]
13. Use of 125I-labeled-histamine-cyclosporin C for monitoring serum cyclosporine concentrations in transplantation patients.
Wong PY; Cheung M; Yip TK; Mee AV
Clin Chem; 1986 Mar; 32(3):492-5. PubMed ID: 3948391
[TBL] [Abstract][Full Text] [Related]
14. Saturable binding of cyclosporin A to erythrocytes: estimation of binding parameters in renal transplant patients and implications for bioavailability assessment.
Legg B; Rowland M
Pharm Res; 1988 Feb; 5(2):80-5. PubMed ID: 3073383
[TBL] [Abstract][Full Text] [Related]
15. Evaluation and comparison of therapeutic monitoring of whole-blood levels of cyclosporin A and its metabolites in renal transplantation by HPLC and RIA methods.
Safarcík K; Brozmanová H; Bartos V; Jegorov A; Grundmann M
Clin Chim Acta; 2001 Aug; 310(2):165-71. PubMed ID: 11498082
[TBL] [Abstract][Full Text] [Related]
16. [A direct radioimmunoassay determination of plasma aldosterone using 125I-labeled ligand (ALDOCTK-125 kit)--comparison with method using 3H-labeled ligand (ALDOK kit) (author's transl)].
Nakamuta S; Kawasaki T; Uezono K; Omae T
Fukuoka Igaku Zasshi; 1980 May; 71(5):221-4. PubMed ID: 7399390
[No Abstract] [Full Text] [Related]
17. A model to account for the blood-to-plasma distribution of cyclosporin A in human blood.
Shibata N; Minouchi T; Ono T; Shimakawa H
J Pharmacobiodyn; 1990 Jan; 13(1):20-9. PubMed ID: 2341967
[TBL] [Abstract][Full Text] [Related]
18. Effects of temperature and endogenous factors in blood on concentrations of cyclosporin in plasma measured by high-performance liquid chromatography.
Shibata N; Minouchi T; Hayashi Y; Shibata H; Ono T; Shimakawa H
Chem Pharm Bull (Tokyo); 1989 Jul; 37(7):1877-80. PubMed ID: 2805168
[TBL] [Abstract][Full Text] [Related]
19. Predictive value of cyclosporin A level for efficacy or renal dysfunction in psoriasis.
Feutren G; Friend D; Timonen P; Barnes A; Laburte C
Br J Dermatol; 1990 Jun; 122 Suppl 36():85-93. PubMed ID: 2369572
[TBL] [Abstract][Full Text] [Related]
20. Abbott's fluorescence polarization immunoassay for cyclosporine and metabolites compared with the Sandoz "Sandimmune" RIA.
Sanghvi A; Diven W; Seltman H; Starzl T
Clin Chem; 1988 Sep; 34(9):1904-6. PubMed ID: 3416444
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]