These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

134 related articles for article (PubMed ID: 35226681)

  • 1. Alternative pre-analytic sample handling techniques for glucose measurement in the absence of fluoride tubes in low resource settings.
    Nakanga WP; Balungi P; Niwaha AJ; Shields BM; Hughes P; Andrews RC; Mc Donald TJ; Nyirenda MJ; Hattersley AT
    PLoS One; 2022; 17(2):e0264432. PubMed ID: 35226681
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Five days serum glucose stability at room-temperature in centrifuged fast-clotting serum tubes and the comparability with glucose in heparin-plasma and plasma containing citrate-stabilizer.
    Bakkebø H; Haaland KL; Hoff KS; Schwettmann L
    Scand J Clin Lab Invest; 2024 Feb; 84(1):62-67. PubMed ID: 38451167
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effectiveness of citrate buffer-fluoride mixture in Terumo tubes as an inhibitor of in vitro glycolysis.
    Bonetti G; Carta M; Montagnana M; Lo Cascio C; Bonfigli AR; Mosca A; Testa R;
    Biochem Med (Zagreb); 2016; 26(1):68-76. PubMed ID: 26981020
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Glucose is stable during prolonged storage in un-centrifuged Greiner tubes with liquid citrate buffer, but not in serum and NaF/KOx tubes.
    Juricic G; Bakliza A; Saracevic A; Kopcinovic LM; Dobrijevic S; Drmic S; Simundic AM
    Clin Chem Lab Med; 2016 Mar; 54(3):411-8. PubMed ID: 26695197
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Which sample tube should be used for routine glucose determination?
    Bonetti G; Cancelli V; Coccoli G; Piccinelli G; Brugnoni D; Caimi L; Carta M
    Prim Care Diabetes; 2016 Jun; 10(3):227-32. PubMed ID: 26657574
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Glucose variation in centrifuged serum and lithium-heparin gel tubes stored for up to 96 hours at room temperature or 4 °C.
    Balboni F; Burbui S; Lippi G
    Scand J Clin Lab Invest; 2018; 78(7-8):546-550. PubMed ID: 30755098
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Acid freezes uricolysis in addition to glycolysis: Utility of fluoride-EDTA-citrate tube in the measurement of uric acid for patients administered rasburicase.
    Kalaria T; Fenn J; Whitmill R; Ford C; Gama R
    Ann Clin Biochem; 2022 May; 59(3):178-182. PubMed ID: 34989247
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Stability of glucose in plasma with different anticoagulants.
    Fobker M
    Clin Chem Lab Med; 2014 Jul; 52(7):1057-60. PubMed ID: 24633752
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Rapid blood separation is superior to fluoride for preventing in vitro reductions in measured blood glucose concentration.
    Shi RZ; Seeley ES; Bowen R; Faix JD
    J Clin Pathol; 2009 Aug; 62(8):752-3. PubMed ID: 19638548
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effects of blood sample collection and preparation methods on concentrations of glucose and nonesterified fatty acids in dairy cattle.
    Drackley JK
    JDS Commun; 2023 Nov; 4(6):454-457. PubMed ID: 38045888
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effect of anticoagulants on plasma homocysteine determination.
    Calişkan S; Kuralay F; Onvural B
    Clin Chim Acta; 2001 Jul; 309(1):53-6. PubMed ID: 11408006
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Impact of blood sample collection and processing methods on glucose levels in community outreach studies.
    Turchiano M; Nguyen C; Fierman A; Lifshitz M; Convit A
    J Environ Public Health; 2013; 2013():256151. PubMed ID: 23365588
    [TBL] [Abstract][Full Text] [Related]  

  • 13. What is the most suitable blood collection tube for glucose estimation?
    Dimeski G; Yow KS; Brown NN
    Ann Clin Biochem; 2015 Mar; 52(Pt 2):270-5. PubMed ID: 25002707
    [TBL] [Abstract][Full Text] [Related]  

  • 14. It takes acid, rather than ice, to freeze glucose.
    van den Berg SA; Thelen MH; Salden LP; van Thiel SW; Boonen KJ
    Sci Rep; 2015 Mar; 5():8875. PubMed ID: 25748167
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Technical and clinical validation of the Greiner FC-Mix glycaemia tube.
    van der Hagen EAE; Fokkert MJ; Kleefman AMD; Thelen MHM; van den Berg SAA; Slingerland RJ
    Clin Chem Lab Med; 2017 Aug; 55(10):1530-1536. PubMed ID: 28284032
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Glucose Stability Study: NaF/Citrate Plasma Versus Serum.
    Zhang X; Rong C; Li H; Qin X; Li S; Lai Z; Chen X
    Clin Lab; 2016; 62(3):389-93. PubMed ID: 27156328
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Parathormone stability in hemodialyzed patients and healthy subjects: comparison on non-centrifuged EDTA and serum samples with second- and third-generation assays.
    Schleck ML; Souberbielle JC; Delanaye P; Plebani M; Cavalier E
    Clin Chem Lab Med; 2017 Jul; 55(8):1152-1159. PubMed ID: 28099122
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Effectiveness of sodium fluoride as a glycolysis inhibitor on blood glucose measurement: comparison of blood glucose using specimens from the Korea National Health and Nutrition Examination survey].
    Lee YW; Cha YJ; Chae SL; Song J; Yun YM; Park HI; Seong MW; Whang DH; Kim HS; Kim JH; Lee BS; Hwang YS
    Korean J Lab Med; 2009 Dec; 29(6):524-8. PubMed ID: 20046083
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effect of Addition of WZB117 as an Inhibitor of Glucose Transporter 1 for Venous Blood Glucose Determination.
    Zhang L; Ran Y; Zhu Y; Zhen Q
    Lab Med; 2021 Mar; 52(2):197-201. PubMed ID: 32789453
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Use of different anticoagulants in test tubes for analysis of blood lactate concentrations: Part 2. Implications for the proper handling of blood specimens obtained from critically ill patients.
    Wiese J; Didwania A; Kerzner R; Chernow B
    Crit Care Med; 1997 Nov; 25(11):1847-50. PubMed ID: 9366768
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.