These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
112 related articles for article (PubMed ID: 35227383)
1. Predicting the uniqueness of single non-negative profiles estimated by multivariate curve resolution methods. Akbari Lakeh M; Abdollahi H; Rajkó R Anal Chim Acta; 2022 Mar; 1199():339575. PubMed ID: 35227383 [TBL] [Abstract][Full Text] [Related]
2. Definition and detection of data-based uniqueness in evaluating bilinear (two-way) chemical measurements. Rajkó R; Abdollahi H; Beyramysoltan S; Omidikia N Anal Chim Acta; 2015 Jan; 855():21-33. PubMed ID: 25542086 [TBL] [Abstract][Full Text] [Related]
3. Known-value constraint in multivariate curve resolution. Akbari Lakeh M; Abdollahi H Anal Chim Acta; 2018 Nov; 1030():42-51. PubMed ID: 30032772 [TBL] [Abstract][Full Text] [Related]
4. Evaluation of the extension of rotation ambiguity associated to multivariate curve resolution solutions by the application of the MCR-BANDS method. Zhang X; Zhang Z; Tauler R Talanta; 2019 Sep; 202():554-564. PubMed ID: 31171221 [TBL] [Abstract][Full Text] [Related]
5. Duality based direct resolution of unique profiles using zero concentration region information. Tavakkoli E; Rajkó R; Abdollahi H Talanta; 2018 Jul; 184():557-564. PubMed ID: 29674081 [TBL] [Abstract][Full Text] [Related]
6. Quantifying the Prediction Error in Analytical Multivariate Curve Resolution Studies of Multicomponent Systems. Pellegrino Vidal RB; Olivieri AC; Tauler R Anal Chem; 2018 Jun; 90(11):7040-7047. PubMed ID: 29749233 [TBL] [Abstract][Full Text] [Related]
7. Contribution to second-order calibration based on multivariate curve resolution with and without previous chromatographic synchronization. Pellegrino Vidal RB; Olivieri AC Anal Chim Acta; 2019 Oct; 1078():8-15. PubMed ID: 31358232 [TBL] [Abstract][Full Text] [Related]
8. A New Parameter for Measuring the Prediction Uncertainty Produced by Rotational Ambiguity in Second-Order Calibration with Multivariate Curve Resolution. Pellegrino Vidal RB; Olivieri AC Anal Chem; 2020 Jul; 92(13):9118-9123. PubMed ID: 32462876 [TBL] [Abstract][Full Text] [Related]
9. Local Rank Deficiency Caused Problems in Analyzing Chemical Data. Akbari Lakeh M; Rajkó R; Abdollahi H Anal Chem; 2017 Feb; 89(4):2259-2266. PubMed ID: 28192909 [TBL] [Abstract][Full Text] [Related]
10. Multivariate curve resolution-particle swarm optimization: a high-throughput approach to exploit pure information from multi-component hyphenated chromatographic signals. Parastar H; Ebrahimi-Najafabadi H; Jalali-Heravi M Anal Chim Acta; 2013 Apr; 772():16-25. PubMed ID: 23540243 [TBL] [Abstract][Full Text] [Related]
11. Multivariate curve resolution based chromatographic peak alignment combined with parallel factor analysis to exploit second-order advantage in complex chromatographic measurements. Parastar H; Akvan N Anal Chim Acta; 2014 Mar; 816():18-27. PubMed ID: 24580851 [TBL] [Abstract][Full Text] [Related]
12. Reaction rate ambiguities for perturbed spectroscopic data: Theory and implementation. Schröder H; Ruckebusch C; Brächer A; Sawall M; Meinhardt D; Kubis C; Mostafapour S; Börner A; Franke R; Neymeyr K Anal Chim Acta; 2020 Nov; 1137():170-180. PubMed ID: 33153600 [TBL] [Abstract][Full Text] [Related]
13. Investigating the discrimination potential of linear and nonlinear spectral multivariate calibrations for analysis of phenolic compounds in their binary and ternary mixtures and calculation pKa values. Rasouli Z; Ghavami R Spectrochim Acta A Mol Biomol Spectrosc; 2016 Aug; 165():191-200. PubMed ID: 27176001 [TBL] [Abstract][Full Text] [Related]
14. Combination of multivariate curve resolution and multivariate classification techniques for comprehensive high-performance liquid chromatography-diode array absorbance detection fingerprints analysis of Salvia reuterana extracts. Hakimzadeh N; Parastar H; Fattahi M J Chromatogr A; 2014 Jan; 1326():63-72. PubMed ID: 24377736 [TBL] [Abstract][Full Text] [Related]
15. Blind end-member and abundance extraction for multispectral fluorescence lifetime imaging microscopy data. Gutierrez-Navarro O; Campos-Delgado DU; Arce-Santana ER; Mendez MO; Jo JA IEEE J Biomed Health Inform; 2014 Mar; 18(2):606-17. PubMed ID: 24608060 [TBL] [Abstract][Full Text] [Related]
16. Performance assessment of chemometric resolution methods utilized for extraction of pure components from overlapped signals in gas chromatography-mass spectrometry. Seifi H; Masoum S; Seifi S J Chromatogr A; 2014 Oct; 1365():173-82. PubMed ID: 25219524 [TBL] [Abstract][Full Text] [Related]
17. On uniqueness and selectivity in three-component parallel factor analysis. Omidikia N; Abdollahi H; Kompany-Zareh M Anal Chim Acta; 2013 Jun; 782():12-20. PubMed ID: 23708279 [TBL] [Abstract][Full Text] [Related]
18. Overlapping spectra resolution using non-negative matrix factorization. Gao HT; Li TH; Chen K; Li WG; Bi X Talanta; 2005 Mar; 66(1):65-73. PubMed ID: 18969963 [TBL] [Abstract][Full Text] [Related]