These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

229 related articles for article (PubMed ID: 3522878)

  • 1. Clinically oriented evaluation of the accuracy of commonly used impression materials.
    Tjan AH; Whang SB; Tjan AH; Sarkissian R
    J Prosthet Dent; 1986 Jul; 56(1):4-8. PubMed ID: 3522878
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Dimensional stability and detail reproduction of irreversible hydrocolloid and elastomeric impressions disinfected by immersion.
    Johnson GH; Chellis KD; Gordon GE; Lepe X
    J Prosthet Dent; 1998 Apr; 79(4):446-53. PubMed ID: 9576321
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Studies on the accuracy of elastomeric impression materials. Part 2. Comparison of dimensional accuracy of casts made by both single polyether rubber impression and the combined reversible and irreversible hydrocolloid impression technique (author's transl)].
    Shigeto N; Inohara N; Yamada S
    Hiroshima Daigaku Shigaku Zasshi; 1978; 10(1):98-108. PubMed ID: 396327
    [No Abstract]   [Full Text] [Related]  

  • 4. Dimensional stability of elastomeric impression materials in custom-made and stock trays.
    Valderhaug J; Fløystrand F
    J Prosthet Dent; 1984 Oct; 52(4):514-7. PubMed ID: 6389833
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [The accuracy of post-impressions with silicone-rubber impression materials and polysulfide-rubber impression materials].
    Aoyama S; Sano Y; Enomoto M; Hanamura N
    Tsurumi Shigaku; 1980 Jun; 6(1):35-40. PubMed ID: 6935848
    [No Abstract]   [Full Text] [Related]  

  • 6. Dimensional accuracy of dental casts: influence of tray material, impression material, and time.
    Thongthammachat S; Moore BK; Barco MT; Hovijitra S; Brown DT; Andres CJ
    J Prosthodont; 2002 Jun; 11(2):98-108. PubMed ID: 12087547
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effect of material bulk and undercuts on the accuracy of impression materials.
    de Araujo PA; Jorgensen KD
    J Prosthet Dent; 1985 Dec; 54(6):791-4. PubMed ID: 3908659
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The effects of disposable and custom-made impression trays on the accuracy of impressions.
    Burton JF; Hood JA; Plunkett DJ; Johnson SS
    J Dent; 1989 Jun; 17(3):121-3. PubMed ID: 2671076
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Copper electroplating of non-aqueous elastomeric impression materials: a subjective appraisal of their platability.
    Payne JA; Jeganathan S
    Singapore Dent J; 1994 Jan; 19(1):14-7. PubMed ID: 9582678
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Time-dependent accuracy of elastomer impression materials. Part I: Condensation silicones.
    Lacy AM; Bellman T; Fukui H; Jendresen MD
    J Prosthet Dent; 1981 Feb; 45(2):209-15. PubMed ID: 7009840
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Flowing of light-bodied elastic impression materials.
    Hegdahl T; Gjerdet NR
    Acta Odontol Scand; 1981; 39(1):33-8. PubMed ID: 6943907
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Accuracy of alginate and elastomeric impression materials.
    Peutzfeldt A; Asmussen E
    Scand J Dent Res; 1989 Aug; 97(4):375-9. PubMed ID: 2678420
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Evaluation of accuracy and the time-dependent dimensional stability of silicone based impression materials].
    Yavuzyilmaz H; Dinçer C; Nalbant L
    Ankara Univ Hekim Fak Derg; 1989 Sep; 16(3):425-8. PubMed ID: 2489491
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of dimensional stability of elastomeric impression materials during disinfection.
    Oda Y; Matsumoto T; Sumii T
    Bull Tokyo Dent Coll; 1995 Feb; 36(1):1-7. PubMed ID: 8689737
    [TBL] [Abstract][Full Text] [Related]  

  • 15. 3D evaluation of the effect of disinfectants on dimensional accuracy and stability of two elastomeric impression materials.
    Soganci G; Cinar D; Caglar A; Yagiz A
    Dent Mater J; 2018 Jul; 37(4):675-684. PubMed ID: 29848853
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of reversible hydrocolloid impression material in a wet field.
    Stewart GP; Bagley RL; Froemling RA
    J Prosthet Dent; 1984 Jun; 51(6):797-800. PubMed ID: 6376782
    [No Abstract]   [Full Text] [Related]  

  • 17. The combined reversible hydrocolloid/irreversible hydrocolloid impression system.
    Appleby DC; Pameijer CH; Boffa J
    J Prosthet Dent; 1980 Jul; 44(1):27-35. PubMed ID: 6991676
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Rheological properties of elastomeric impression materials].
    Kikuchi M
    Aichi Gakuin Daigaku Shigakkai Shi; 1990 Dec; 28(4):1287-302. PubMed ID: 2135157
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Three-dimensional investigation of the accuracy of impression materials after disinfection.
    Kern M; Rathmer RM; Strub JR
    J Prosthet Dent; 1993 Nov; 70(5):449-56. PubMed ID: 8254550
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The effect of the type and technique used for impression making on the accuracy of elastomeric impression materials.
    Habib AN; Shehata MT
    Egypt Dent J; 1995 Oct; 41(4):1409-16. PubMed ID: 9497690
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.