BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

222 related articles for article (PubMed ID: 35230517)

  • 1. Coronary calcium scores on dual-source photon-counting computed tomography: an adapted Agatston methodology aimed at radiation dose reduction.
    van der Werf NR; Greuter MJW; Booij R; van der Lugt A; Budde RPJ; van Straten M
    Eur Radiol; 2022 Aug; 32(8):5201-5209. PubMed ID: 35230517
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Reproducibility of coronary artery calcium quantification on dual-source CT and dual-source photon-counting CT: a dynamic phantom study.
    van der Werf NR; Booij R; Greuter MJW; Bos D; van der Lugt A; Budde RPJ; van Straten M
    Int J Cardiovasc Imaging; 2022 Jul; 38(7):1613-1619. PubMed ID: 35113282
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Dose Reduction in Coronary Artery Calcium Scoring Using Mono-Energetic Images from Reduced Tube Voltage Dual-Source Photon-Counting CT Data: A Dynamic Phantom Study.
    van der Werf NR; van Gent M; Booij R; Bos D; van der Lugt A; Budde RPJ; Greuter MJW; van Straten M
    Diagnostics (Basel); 2021 Nov; 11(12):. PubMed ID: 34943428
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Radiation dose optimization for photon-counting CT coronary artery calcium scoring for different patient sizes: a dynamic phantom study.
    Dobrolinska MM; van der Werf NR; van der Bie J; de Groen J; Dijkshoorn M; Booij R; Budde RPJ; Greuter MJW; van Straten M
    Eur Radiol; 2023 Jul; 33(7):4668-4675. PubMed ID: 36729174
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Improved coronary calcium detection and quantification with low-dose full field-of-view photon-counting CT: a phantom study.
    van der Werf NR; Rodesch PA; Si-Mohamed S; van Hamersvelt RW; Greuter MJW; Leiner T; Boussel L; Willemink MJ; Douek P
    Eur Radiol; 2022 May; 32(5):3447-3457. PubMed ID: 34997284
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluating a calcium-aware kernel for CT CAC scoring with varying surrounding materials and heart rates: a dynamic phantom study.
    van der Werf NR; Booij R; Schmidt B; Flohr TG; Leiner T; de Groen JJ; Bos D; Budde RPJ; Willemink MJ; Greuter MJW
    Eur Radiol; 2021 Dec; 31(12):9211-9220. PubMed ID: 34050386
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Feasibility of virtual non-iodine coronary calcium scoring on dual source photon-counting coronary CT angiography: a dynamic phantom study.
    Dobrolinska MM; Koetzier LR; Greuter MJW; Vliegenthart R; van der Bie J; Prakken NHJ; Slart RHJA; Leiner T; Budde RPJ; Mastrodicasa D; Booij R; Fleischmann D; Willemink MJ; van Straten M; van der Werf NR
    Eur Radiol; 2024 May; ():. PubMed ID: 38789792
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Dose reduction for CT coronary calcium scoring with a calcium-aware image reconstruction technique: a phantom study.
    Booij R; van der Werf NR; Budde RPJ; Bos D; van Straten M
    Eur Radiol; 2020 Jun; 30(6):3346-3355. PubMed ID: 32072259
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Coronary calcium scoring potential of large field-of-view spectral photon-counting CT: a phantom study.
    van der Werf NR; Si-Mohamed S; Rodesch PA; van Hamersvelt RW; Greuter MJW; Boccalini S; Greffier J; Leiner T; Boussel L; Willemink MJ; Douek P
    Eur Radiol; 2022 Jan; 32(1):152-162. PubMed ID: 34255159
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Adaptive Iterative Dose Reduction 3D Integrated with Automatic Tube Current Modulation for CT Coronary Artery Calcium Quantification: Comparison to Traditional Filtered Back Projection in an Anthropomorphic Phantom and Patients.
    Tang YC; Liu YC; Hsu MY; Tsai HY; Chen CM
    Acad Radiol; 2018 Aug; 25(8):1010-1017. PubMed ID: 29395796
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Fully automated quantification method (FQM) of coronary calcium in an anthropomorphic phantom.
    van Praagh GD; van der Werf NR; Wang J; van Ommen F; Poelhekken K; Slart RHJA; Fleischmann D; Greuter MJW; Leiner T; Willemink MJ
    Med Phys; 2021 Jul; 48(7):3730-3740. PubMed ID: 33932026
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The impact of CT radiation dose reduction and iterative reconstruction algorithms from four different vendors on coronary calcium scoring.
    Willemink MJ; Takx RA; de Jong PA; Budde RP; Bleys RL; Das M; Wildberger JE; Prokop M; Buls N; de Mey J; Schilham AM; Leiner T
    Eur Radiol; 2014 Sep; 24(9):2201-12. PubMed ID: 24889996
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Systematic assessment of coronary calcium detectability and quantification on four generations of CT reconstruction techniques: a patient and phantom study.
    Dobrolinska MM; van Praagh GD; Oostveen LJ; Poelhekken K; Greuter MJW; Fleischmann D; Willemink MJ; de Lange F; Slart RHJA; Leiner T; van der Werf NR
    Int J Cardiovasc Imaging; 2023 Jan; 39(1):221-231. PubMed ID: 36598691
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Coronary Calcium Scoring with First Generation Dual-Source Photon-Counting CT-First Evidence from Phantom and In-Vivo Scans.
    Eberhard M; Mergen V; Higashigaito K; Allmendinger T; Manka R; Flohr T; Schmidt B; Euler A; Alkadhi H
    Diagnostics (Basel); 2021 Sep; 11(9):. PubMed ID: 34574049
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Impact of deep learning image reconstructions (DLIR) on coronary artery calcium quantification.
    Rossi A; Gennari AG; Etter D; Benz DC; Sartoretti T; Giannopoulos AA; Mikail N; Bengs S; Maurer A; Gebhard C; Buechel RR; Kaufmann PA; Fuchs TA; Messerli M
    Eur Radiol; 2023 Jun; 33(6):3832-3838. PubMed ID: 36480026
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Coronary artery calcium quantification using contrast-enhanced dual-energy computed tomography scans in comparison with unenhanced single-energy scans.
    Li Q; Berman BP; Hagio T; Gavrielides MA; Zeng R; Sahiner B; Gong Q; Fang Y; Liu S; Petrick N
    Phys Med Biol; 2018 Aug; 63(17):175006. PubMed ID: 30101756
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Coronary artery calcium scoring with photon-counting CT: first in vivo human experience.
    Symons R; Sandfort V; Mallek M; Ulzheimer S; Pourmorteza A
    Int J Cardiovasc Imaging; 2019 Apr; 35(4):733-739. PubMed ID: 30635819
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Finding the optimal dose reduction and iterative reconstruction level for coronary calcium scoring.
    Willemink MJ; den Harder AM; Foppen W; Schilham AM; Rienks R; Laufer EM; Nieman K; de Jong PA; Budde RP; Nathoe HM; Leiner T
    J Cardiovasc Comput Tomogr; 2016; 10(1):69-75. PubMed ID: 26342405
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Tube voltage-independent coronary calcium scoring on a first-generation dual-source photon-counting CT-a proof-of-principle phantom study.
    Mergen V; Higashigaito K; Allmendinger T; Manka R; Euler A; Alkadhi H; Eberhard M
    Int J Cardiovasc Imaging; 2022 Apr; 38(4):905-912. PubMed ID: 34780012
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Coronary artery calcium quantification on first, second and third generation dual source CT: A comparison study.
    Vonder M; Pelgrim GJ; Huijsse SEM; Haubenreisser H; Meyer M; van Ooijen PMA; Oudkerk M; Henzler T; Vliegenthart R
    J Cardiovasc Comput Tomogr; 2017 Nov; 11(6):444-448. PubMed ID: 28943454
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.