These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
3. The OregonHeart Total Artificial Heart: Design and Performance on a Mock Circulatory Loop. Glynn J; Song H; Hull B; Withers S; Gelow J; Mudd J; Starr A; Wampler R Artif Organs; 2017 Oct; 41(10):904-910. PubMed ID: 28703280 [TBL] [Abstract][Full Text] [Related]
4. Video-based valve motion combined with computational fluid dynamics gives stable and accurate simulations of blood flow in the Realheart total artificial heart. Kelly NS; McCree D; Fresiello L; Brynedal Ignell N; Cookson AN; Najar A; Perkins IL; Fraser KH Artif Organs; 2022 Jan; 46(1):57-70. PubMed ID: 34460941 [TBL] [Abstract][Full Text] [Related]
5. Anatomical and Hemodynamic Characterization of Totally Artificial Hearts. Monreal G; Koenig SC; Huang J; Slaughter MS ASAIO J; 2024 May; 70(5):338-347. PubMed ID: 38557701 [TBL] [Abstract][Full Text] [Related]
6. Anatomic fitting of total artificial hearts for in vivo evaluation. Gregory SD; Loechel N; Pearcy MJ; Fraser J; Parnis S; Cohn WE; Timms D Artif Organs; 2013 Aug; 37(8):735-41. PubMed ID: 23461712 [TBL] [Abstract][Full Text] [Related]
7. In vitro hemolytic performance of the Realheart® V11C TAH prototype with porcine blood. Perkins IL; Mansisidor EM; Zaman SF; Mudge K; Bodger O; Najar A Artif Organs; 2023 Jul; 47(7):1208-1213. PubMed ID: 37032479 [TBL] [Abstract][Full Text] [Related]
8. Current Role of the Total Artificial Heart in the Management of Advanced Heart Failure. Melton N; Soleimani B; Dowling R Curr Cardiol Rep; 2019 Nov; 21(11):142. PubMed ID: 31758343 [TBL] [Abstract][Full Text] [Related]
9. Continuous flow total artificial heart: modeling and feedback control in a mock circulatory system. Khalil HA; Kerr DT; Franchek MA; Metcalfe RW; Benkowski RJ; Cohn WE; Tuzun E; Radovancevic B; Frazier OH; Kadipasaoglu KA ASAIO J; 2008; 54(3):249-55. PubMed ID: 18496274 [TBL] [Abstract][Full Text] [Related]
10. In vitro controllability of the MagScrew total artificial heart system. Weber S; Doi K; Massiello AL; Byerman BP; Takagaki M; Fukamachi K; Donahue A; Chapman P; Hirschman G; Vitale N; Smith WA ASAIO J; 2002; 48(6):606-11. PubMed ID: 12455770 [TBL] [Abstract][Full Text] [Related]
11. Controlling the flow balance: In vitro characterization of a pulsatile total artificial heart in preload and afterload sensitivity. Hildebrand S; Diedrich M; Brockhaus M; Finocchiaro T; Cuenca E; De Ben H; Steinseifer U; Schmitz-Rode T; Jansen SV Artif Organs; 2022 Jan; 46(1):71-82. PubMed ID: 34287976 [TBL] [Abstract][Full Text] [Related]
12. Versatile one-piece total artificial heart for bridge to transplantation or permanent heart replacement. Orime Y; Takatani S; Shiono M; Sasaki T; Minato N; Ohara Y; Swenson CA; Noon GP; Nosé Y; DeBakey ME Artif Organs; 1992 Dec; 16(6):607-13. PubMed ID: 1482331 [TBL] [Abstract][Full Text] [Related]
13. A nonpulsatile total artificial heart with 1/R control. Abe Y; Saito I; Isoyama T; Miura H; Shi W; Yamaguchi S; Inoue Y; Nakagawa H; Ono M; Kishi A; Ono T; Kouno A; Chinzei T; Imachi K J Artif Organs; 2008; 11(4):191-200. PubMed ID: 19184283 [TBL] [Abstract][Full Text] [Related]
14. Physiological characterization of the SynCardia total artificial heart in a mock circulation system. Crosby JR; DeCook KJ; Tran PL; Smith RG; Larson DF; Khalpey ZI; Burkhoff D; Slepian MJ ASAIO J; 2015; 61(3):274-81. PubMed ID: 25551416 [TBL] [Abstract][Full Text] [Related]
15. Mock circulation loop to investigate hemolysis in a pulsatile total artificial heart. Gräf F; Finocchiaro T; Laumen M; Mager I; Steinseifer U Artif Organs; 2015 May; 39(5):416-22. PubMed ID: 25586541 [TBL] [Abstract][Full Text] [Related]
16. Development of a flow-transformed pulsatile total artificial heart for total implantation. Imachi K; Chinzei T; Abe Y; Mabuchi K; Imanishi K; Yonezawa T; Suzuki A; Isoyama T; Atsumi K; Fujimasa I Artif Organs; 1992 Jun; 16(3):308-13. PubMed ID: 10078267 [TBL] [Abstract][Full Text] [Related]
17. Evaluation of total artificial heart performance in man. Anderson FL; DeVries WC; Anderson JL; Joyce LD Am J Cardiol; 1984 Aug; 54(3):394-8. PubMed ID: 6465023 [TBL] [Abstract][Full Text] [Related]
18. In-vitro performance of a single-chambered total artificial heart in a Fontan circulation. Hildebrand S; Groß-Hardt S; Schmitz-Rode T; Steinseifer U; Jansen SV J Artif Organs; 2022 Mar; 25(1):1-8. PubMed ID: 33956261 [TBL] [Abstract][Full Text] [Related]
19. Investigation of the inherent left-right flow balancing of rotary total artificial hearts by means of a resistance box. Nestler F; Timms DL; Stevens M; Bradley AP; Wilson SJ; Kleinheyer M; Lovell N; Frazier OH; Cohn WE Artif Organs; 2020 Jun; 44(6):584-593. PubMed ID: 31912510 [TBL] [Abstract][Full Text] [Related]
20. Detection of physiological control inputs preload and afterload from intrinsic pump parameters in total artificial heart. Kirn B; Diedrich M; Schmitz-Rode T; Steinseifer U; Jansen SV Artif Organs; 2023 May; 47(5):817-827. PubMed ID: 36495089 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]