  • 21. Evaluation of Combined Extracorporeal Life Support and Continuous Renal Replacement Therapy on Hemodynamic Performance and Gaseous Microemboli Handling Ability in a Simulated Neonatal ECLS System.
    Shank KR; Profeta E; Wang S; O'Connor C; Kunselman AR; Woitas K; Myers JL; Ündar A
    Artif Organs; 2018 Apr; 42(4):365-376. PubMed ID: 28940550
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Impact of Pulsatility and Flow Rates on Hemodynamic Energy Transmission in an Adult Extracorporeal Life Support System.
    Wolfe R; Strother A; Wang S; Kunselman AR; Ündar A
    Artif Organs; 2015 Jul; 39(7):E127-37. PubMed ID: 25894993
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Hemolytic and thrombocytopathic characteristics of extracorporeal membrane oxygenation systems at simulated flow rate for neonates.
    Meyer AD; Wiles AA; Rivera O; Wong EC; Freishtat RJ; Rais-Bahrami K; Dalton HJ
    Pediatr Crit Care Med; 2012 Jul; 13(4):e255-61. PubMed ID: 22596067
    [TBL] [Abstract][Full Text] [Related]  

  • 24. In vitro performance analysis of a novel pulsatile diagonal pump in a simulated pediatric mechanical circulatory support system.
    Wang S; Kunselman AR; Ündar A
    Artif Organs; 2014 Jan; 38(1):64-72. PubMed ID: 24237183
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Impact of pulsatile flow on hemodynamic energy in a Medos Deltastream DP3 pediatric extracorporeal life support system.
    Krawiec C; Wang S; Kunselman AR; Ündar A
    Artif Organs; 2014 Jan; 38(1):19-27. PubMed ID: 23826748
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Evaluation of oxygenators and centrifugal pumps for long-term pediatric extracorporeal membrane oxygenation.
    Thiara AP; Hoel TN; Kristiansen F; Karlsen HM; Fiane AE; Svennevig JL
    Perfusion; 2007 Sep; 22(5):323-6. PubMed ID: 18416217
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Hemodynamic Evaluation of Avalon Elite Bi-Caval Dual Lumen Cannulas and Femoral Arterial Cannulas.
    Wang S; Force M; Kunselman AR; Palanzo D; Brehm C; Ündar A
    Artif Organs; 2019 Jan; 43(1):41-53. PubMed ID: 30273959
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Hemodynamic evaluation of the Avalon Elite bi-caval dual lumen cannulae.
    Qiu F; Lu CK; Palanzo D; Baer LD; Myers JL; Undar A
    Artif Organs; 2011 Nov; 35(11):1048-51. PubMed ID: 21899572
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Mechanical performance comparison between RotaFlow and CentriMag centrifugal blood pumps in an adult ECLS model.
    Yulong Guan ; Xiaowei Su ; McCoach R; Kunselman A; El-Banayosy A; Undar A
    Perfusion; 2010 Mar; 25(2):71-6. PubMed ID: 20212070
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Impact of tubing length on hemodynamics in a simulated neonatal extracorporeal life support circuit.
    Qiu F; Uluer MC; Kunselman A; Clark JB; Myers JL; Undar A
    Artif Organs; 2010 Nov; 34(11):1003-9. PubMed ID: 21092043
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Hemolysis at low blood flow rates: in-vitro and in-silico evaluation of a centrifugal blood pump.
    Schöps M; Groß-Hardt SH; Schmitz-Rode T; Steinseifer U; Brodie D; Clauser JC; Karagiannidis C
    J Transl Med; 2021 Jan; 19(1):2. PubMed ID: 33402176
    [TBL] [Abstract][Full Text] [Related]  

  • 32. In Vitro Hemodynamic Evaluation of ECG-Synchronized Pulsatile Flow Using i-Cor Pump as Short-Term Cardiac Assist Device for Neonatal and Pediatric Population.
    Force M; Moroi M; Wang S; Kunselman AR; Ündar A
    Artif Organs; 2018 Aug; 42(8):E153-E167. PubMed ID: 29682761
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Hemodynamic evaluation of arterial and venous cannulae performance in a simulated neonatal extracorporeal life support circuit.
    Qiu F; Clark JB; Kunselman AR; Undar A; Myers JL
    Perfusion; 2011 Jul; 26(4):276-83. PubMed ID: 21558147
    [TBL] [Abstract][Full Text] [Related]  

  • 34. In vitro hemodynamic evaluation of a novel pulsatile extracorporeal life support system: impact of perfusion modes and circuit components on energy loss.
    Wang S; Kunselman AR; Clark JB; Ündar A
    Artif Organs; 2015 Jan; 39(1):59-66. PubMed ID: 25586773
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Hemostatic Complications During Neonatal Extracorporeal Membrane Oxygenation: Roller Pump and Centrifugal Pump Driven Circuits.
    Vermeer H; de Jong SF; Koers EJ; Peeters TLM; van der Lee R; de Boode WP; Morshuis WJ
    ASAIO J; 2023 Jun; 69(6):618-624. PubMed ID: 36574471
    [TBL] [Abstract][Full Text] [Related]  

  • 36. In Vitro Hemodynamic Evaluation of an Adult Pulsatile Extracorporeal Membrane Oxygenation System.
    Wang S; Moroi M; Brehm CE; Kunselman AR; Ündar A
    Artif Organs; 2018 Sep; 42(9):E234-E245. PubMed ID: 29774551
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Evaluation of an
    Kalaria SN; Kishk OA; Gopalakrishnan M; Bagdure DN
    Perfusion; 2022 Nov; 37(8):812-818. PubMed ID: 34192981
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Impact of cannula size and line length on venous line pressure in pediatric VA-/VV-ECLS circuits.
    Wang S; Kunselman AR; Ündar A
    Artif Organs; 2019 Aug; 43(8):E165-E177. PubMed ID: 30589448
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Comparison of pressure-volume-flow relationships in centrifugal and roller pump extracorporeal membrane oxygenation systems for neonates.
    Green TP; Kriesmer P; Steinhorn RH; Payne NR; Irmiter RJ; Meyer CL
    ASAIO Trans; 1991; 37(4):572-6. PubMed ID: 1768491
    [TBL] [Abstract][Full Text] [Related]  

  • 40. In vitro comparison of the delivery of gaseous microemboli and hemodynamic energy for a diagonal and a roller pump during simulated infantile cardiopulmonary bypass procedures.
    Dhami R; Wang S; Kunselman AR; Ündar A
    Artif Organs; 2014 Jan; 38(1):56-63. PubMed ID: 23876021
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.