These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

173 related articles for article (PubMed ID: 35244820)

  • 1. Daily ECG transmission versus serial 6-day Holter ECG for the assessment of efficacy of ablation for atrial fibrillation - the AGNES-ECG study.
    Sikorska A; Baran J; Piotrowski R; Kryński T; Szymot J; Soszyńska M; Kułakowski P
    J Interv Card Electrophysiol; 2022 Nov; 65(2):373-380. PubMed ID: 35244820
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Role of transtelephonic electrocardiographic monitoring in detecting short-term arrhythmia recurrences after radiofrequency ablation in patients with atrial fibrillation.
    Senatore G; Stabile G; Bertaglia E; Donnici G; De Simone A; Zoppo F; Turco P; Pascotto P; Fazzari M
    J Am Coll Cardiol; 2005 Mar; 45(6):873-6. PubMed ID: 15766823
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Assessment of atrial fibrillation ablation outcomes with clinic ECG, monthly 24-h Holter ECG, and twice-daily telemonitoring ECG.
    Kimura T; Aizawa Y; Kurata N; Nakajima K; Kashimura S; Kunitomi A; Nishiyama T; Katsumata Y; Nishiyama N; Fukumoto K; Tanimoto Y; Fukuda K; Takatsuki S
    Heart Vessels; 2017 Mar; 32(3):317-325. PubMed ID: 27385021
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Long-term intermittent versus short continuous heart rhythm monitoring for the detection of atrial fibrillation recurrences after catheter ablation.
    Hermans ANL; Gawalko M; Pluymaekers NAHA; Dinh T; Weijs B; van Mourik MJW; Vorstermans B; den Uijl DW; Opsteyn L; Snippe H; Vernooy K; Crijns HJGM; Linz D; Luermans JGLM
    Int J Cardiol; 2021 Apr; 329():105-112. PubMed ID: 33412184
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Randomized crossover trial of 2-week Garment electrocardiogram with dry textile electrode to reveal instances of post-ablation recurrence of atrial fibrillation underdiagnosed during 24-hour Holter monitoring.
    Machino T; Aonuma K; Maruo K; Komatsu Y; Yamasaki H; Igarashi M; Nogami A; Ieda M
    PLoS One; 2023; 18(2):e0281818. PubMed ID: 36827294
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Impact of monitoring on detection of arrhythmia recurrences in the ESC-EHRA EORP atrial fibrillation ablation long-term registry.
    Balabanski T; Brugada J; Arbelo E; Laroche C; Maggioni A; Blomström-Lundqvist C; Kautzner J; Tavazzi L; Tritto M; Kulakowski P; Kalejs O; Forster T; Villalobos FS; Dagres N;
    Europace; 2019 Dec; 21(12):1802-1808. PubMed ID: 31693093
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Diagnostic utility of long-term remote ECG monitoring in compare with 24 hour Holter monitoring in patients with atrial fibrillation after catheter radiofrequency ablation in the early postoperative period.
    Ryabykina GV; Shokhzodaeva ZO; Sapelnikov OV; Makeev MI; Kozhemyakina ES; Shchedrina EV; Volkov VE; Akchurin RS
    Ter Arkh; 2018 Dec; 90(12):12-16. PubMed ID: 30701827
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Using a novel wireless system for monitoring patients after the atrial fibrillation ablation procedure: the iTransmit study.
    Tarakji KG; Wazni OM; Callahan T; Kanj M; Hakim AH; Wolski K; Wilkoff BL; Saliba W; Lindsay BD
    Heart Rhythm; 2015 Mar; 12(3):554-559. PubMed ID: 25460854
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Rhythm Control and Its Relation to Symptoms during the First Two Years after Radiofrequency Ablation for Atrial Fibrillation.
    Björkenheim A; Brandes A; Chemnitz A; Magnuson A; Edvardsson N; Poçi D
    Pacing Clin Electrophysiol; 2016 Sep; 39(9):914-25. PubMed ID: 27418324
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Value of different follow-up strategies to assess the efficacy of circumferential pulmonary vein ablation for the curative treatment of atrial fibrillation.
    Piorkowski C; Kottkamp H; Tanner H; Kobza R; Nielsen JC; Arya A; Hindricks G
    J Cardiovasc Electrophysiol; 2005 Dec; 16(12):1286-92. PubMed ID: 16403058
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of two modes of long-term ECG monitoring to assess the efficacy of catheter ablation for paroxysmal atrial fibrillation.
    Chovancik J; Bulkova V; Wichterle D; Toman O; Rybka L; Januska J; Spinar J; Fiala M
    Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub; 2019 Feb; 163(1):54-60. PubMed ID: 29955186
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Dry textile electrode for ambulatory monitoring after catheter ablation of atrial fibrillation: A pilot study of simultaneous comparison to the Holter electrocardiogram.
    Machino T; Aonuma K; Komatsu Y; Yamasaki H; Igarashi M; Nogami A; Ieda M
    F1000Res; 2022; 11():97. PubMed ID: 35860478
    [No Abstract]   [Full Text] [Related]  

  • 13. :Influence of the duration of Holter monitoring on the detection of arrhythmia recurrences after catheter ablation of atrial fibrillation: implications for patient follow-up.
    Dagres N; Kottkamp H; Piorkowski C; Weis S; Arya A; Sommer P; Bode K; Gerds-Li JH; Kremastinos DT; Hindricks G
    Int J Cardiol; 2010 Mar; 139(3):305-6. PubMed ID: 18990460
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Symptomatic and asymptomatic long-term recurrences following transcatheter atrial fibrillation ablation.
    Manganiello S; Anselmino M; Amellone C; Pelissero E; Giuggia M; Trapani G; Giordano B; Senatore G; Gaita F
    Pacing Clin Electrophysiol; 2014 Jun; 37(6):697-702. PubMed ID: 24665920
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Biatrial maze procedure versus pulmonary vein isolation for atrial fibrillation during mitral valve surgery: New analytical approaches and end points.
    Blackstone EH; Chang HL; Rajeswaran J; Parides MK; Ishwaran H; Li L; Ehrlinger J; Gelijns AC; Moskowitz AJ; Argenziano M; DeRose JJ; Couderc JP; Balda D; Dagenais F; Mack MJ; Ailawadi G; Smith PK; Acker MA; O'Gara PT; Gillinov AM;
    J Thorac Cardiovasc Surg; 2019 Jan; 157(1):234-243.e9. PubMed ID: 30557941
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [A comparison of two methods of long-term external ECG telemonitoring in patients after ablation for atrial fibrillation].
    Chovančík J; Bulková V; Fiala M; Gandalovičová J; Královec S; Neuwirth R; Tolaszová H; Jiravský O; Brada J; Januška J
    Vnitr Lek; 2012 Sep; 58(9):633-9. PubMed ID: 23094807
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Higher burden of supraventricular ectopic complexes early after catheter ablation for atrial fibrillation is associated with increased risk of recurrent atrial fibrillation.
    Alhede C; Johannessen A; Dixen U; Jensen JS; Raatikainen P; Hindricks G; Walfridsson H; Kongstad O; Pehrson S; Englund A; Hartikainen J; Hansen PS; Nielsen JC; Jons C
    Europace; 2018 Jan; 20(1):50-57. PubMed ID: 28011799
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Early recurrence of atrial fibrillation as a predictor for 1-year efficacy after successful phased RF pulmonary vein isolation: evaluation of complaints and multiple Holter recordings.
    Mulder AA; Wijffels MC; Wever EF; Boersma LV
    Int J Cardiol; 2013 Apr; 165(1):56-60. PubMed ID: 21862151
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Association of Atrial Fibrillation Episode Duration With Arrhythmia Recurrence Following Ablation: A Secondary Analysis of a Randomized Clinical Trial.
    Andrade JG; Deyell MW; Verma A; Macle L; Champagne J; Leong-Sit P; Novak P; Badra-Verdu M; Sapp J; Khairy P; Nattel S
    JAMA Netw Open; 2020 Jul; 3(7):e208748. PubMed ID: 32614422
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Accuracy of atrial fibrillation detection by an insertable cardiac monitor in patients undergoing catheter ablation: Results of the BioVAD study.
    Assaf A; Theuns DAMJ; Sakhi R; Bhagwandien RE; Szili-Torok T; Yap SC
    Ann Noninvasive Electrocardiol; 2022 May; 27(3):e12960. PubMed ID: 35481956
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.