These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

195 related articles for article (PubMed ID: 35248558)

  • 1. Intraocular pressure measurement: A review.
    Da Silva F; Lira M
    Surv Ophthalmol; 2022; 67(5):1319-1331. PubMed ID: 35248558
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Fundamentals and Advances in Tonometry.
    Nuyen B; Mansouri K
    Asia Pac J Ophthalmol (Phila); 2015; 4(2):66-75. PubMed ID: 26065347
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Clinical comparison of the TonoVet(®) rebound tonometer and the Tono-Pen Vet(®) applanation tonometer in dogs and cats with ocular disease: glaucoma or corneal pathology.
    von Spiessen L; Karck J; Rohn K; Meyer-Lindenberg A
    Vet Ophthalmol; 2015 Jan; 18(1):20-7. PubMed ID: 24131625
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Difference in intraocular pressure measurements between non-contact tonometry and Goldmann applanation tonometry and the role of central corneal thickness in affecting glaucoma referrals.
    Kamel K; Dervan E; Falzon K; O'Brien C
    Ir J Med Sci; 2019 Feb; 188(1):321-325. PubMed ID: 29616408
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Measuring intraocular pressure-adjustments for corneal thickness and new technologies.
    Herndon LW
    Curr Opin Ophthalmol; 2006 Apr; 17(2):115-9. PubMed ID: 16552245
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effect of corneal parameters on measurements using the pulsatile ocular blood flow tonograph and Goldmann applanation tonometer.
    Gunvant P; Baskaran M; Vijaya L; Joseph IS; Watkins RJ; Nallapothula M; Broadway DC; O'Leary DJ
    Br J Ophthalmol; 2004 Apr; 88(4):518-22. PubMed ID: 15031169
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Optical measurement of the corneal oscillation for the determination of the intraocular pressure.
    Osmers J; Sorg M; Fischer A
    Biomed Tech (Berl); 2019 Aug; 64(4):471-480. PubMed ID: 30231007
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Clinical key points. Intraocular pressure].
    Denis P
    J Fr Ophtalmol; 2007 May; 30(5 Pt 2):3S35-8. PubMed ID: 17646799
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Clinical evaluation of the ICare tonometer in measuring intraocular pressure].
    Krzyzanowska-Berkowska P; Asejczyk-Widlicka M
    Klin Oczna; 2010; 112(7-9):217-20. PubMed ID: 21121124
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Contemporary possibilities of intraocular pressure measurement].
    Hornová J; Baxant A
    Cesk Slov Oftalmol; 2013 Oct; 69(4):175-80. PubMed ID: 24437996
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of intraocular pressure measurement between rebound, non-contact and Goldmann applanation tonometry in treated glaucoma patients.
    Vincent SJ; Vincent RA; Shields D; Lee GA
    Clin Exp Ophthalmol; 2012; 40(4):e163-70. PubMed ID: 21883774
    [TBL] [Abstract][Full Text] [Related]  

  • 12. An overview of home tonometry and telemetry for intraocular pressure monitoring in humans.
    Yung E; Trubnik V; Katz LJ
    Graefes Arch Clin Exp Ophthalmol; 2014 Aug; 252(8):1179-88. PubMed ID: 24888380
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The relationship between measurement method and corneal structure on apparent intraocular pressure in glaucoma and ocular hypertension.
    Nessim M; Mollan SP; Wolffsohn JS; Laiquzzaman M; Sivakumar S; Hartley S; Shah S
    Cont Lens Anterior Eye; 2013 Apr; 36(2):57-61. PubMed ID: 23253796
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The influence of central corneal thickness and age on intraocular pressure measured by pneumotonometry, non-contact tonometry, the Tono-Pen XL, and Goldmann applanation tonometry.
    Tonnu PA; Ho T; Newson T; El Sheikh A; Sharma K; White E; Bunce C; Garway-Heath D
    Br J Ophthalmol; 2005 Jul; 89(7):851-4. PubMed ID: 15965165
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Systematic Review of Current Devices for 24-h Intraocular Pressure Monitoring.
    Ittoop SM; SooHoo JR; Seibold LK; Mansouri K; Kahook MY
    Adv Ther; 2016 Oct; 33(10):1679-1690. PubMed ID: 27531519
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Effects of central corneal thickness and corneal curvature on measurement of intraocular pressure with Goldmann applanation tonometer and non-contact tonometer].
    Zhang Y; Zhao JL; Bian AL; Liu XL; Jin YM
    Zhonghua Yan Ke Za Zhi; 2009 Aug; 45(8):713-8. PubMed ID: 20021884
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Pachymetry and intraocular pressure measurement by corneal visualization Scheimpflug technology (Corvis ST): A clinical comparison to the gold standard].
    Steinberg J; Mehlan J; Frings A; Druchkiv V; Richard G; Katz T; Linke SJ
    Ophthalmologe; 2015 Sep; 112(9):770-7. PubMed ID: 25501931
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparative analysis of biomechanically corrected intraocular pressure with corneal visualization Scheimpflug technology versus conventional noncontact intraocular pressure.
    Ma J; Wang Y; Hao W; Jhanji V
    Int Ophthalmol; 2020 Jan; 40(1):117-124. PubMed ID: 31432352
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Correlation between diurnal variation of intraocular pressure, ocular pulse amplitude and corneal structural properties.
    Villas-Bôas FS; Doi LM; Sousa AK; Melo LA
    Arq Bras Oftalmol; 2009; 72(3):296-301. PubMed ID: 19668956
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [What to do if the intraocular pressure measurement does not appear reliable].
    Hamard P
    J Fr Ophtalmol; 2010 Apr; 33(4):279-84. PubMed ID: 20347507
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.