BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

169 related articles for article (PubMed ID: 35252453)

  • 1. Finite Element Analysis of Unilateral versus Bipedicular Bone-Filling Mesh Container for the Management of Osteoporotic Compression Fractures.
    Lu H; Zhang Q; Ding F; Wu Q; Liu R
    Biomed Res Int; 2022; 2022():6850089. PubMed ID: 35252453
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Do we have to pursue complete reduction after PVA in osteoporotic vertebral compression fractures: a finite element analysis.
    Fan Z; Huang H; Lin Y; Zhou J; Lin F; Chen B; Wang H; Su H; Qi J; Huang Y; Huang Y
    Injury; 2022 Aug; 53(8):2754-2762. PubMed ID: 35760641
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Finite element analysis of wedge and biconcave deformity in four different height restoration after augmentation of osteoporotic vertebral compression fractures.
    Zuo XH; Chen YB; Xie P; Zhang WD; Xue XY; Zhang QX; Shan B; Zhang XB; Bao HG; Si YN
    J Orthop Surg Res; 2021 Feb; 16(1):138. PubMed ID: 33588890
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Biomechanical effects of different vertebral heights after augmentation of osteoporotic vertebral compression fracture: a three-dimensional finite element analysis.
    Zhao WT; Qin DP; Zhang XG; Wang ZP; Tong Z
    J Orthop Surg Res; 2018 Feb; 13(1):32. PubMed ID: 29422073
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Finite Element Analysis of a New Type of Spinal Protection Device for the Prevention and Treatment of Osteoporotic Vertebral Compression Fractures.
    Che M; Wang Y; Zhao Y; Zhang S; Yu J; Gong W; Zhang D; Liu M
    Orthop Surg; 2022 Mar; 14(3):577-586. PubMed ID: 35147295
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Three dimensional finite element analysis of optimal distribution model of fillers in vertebroplasty].
    Wang DG; Li Y; Yin HL; Li J; Qu J; Jiang MB; Tian JW
    Zhongguo Gu Shang; 2021 Jan; 34(1):26-33. PubMed ID: 33666016
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Cement leakage in osteoporotic vertebral compression fractures with cortical defect using high-viscosity bone cement during unilateral percutaneous kyphoplasty surgery.
    Liu T; Li Z; Su Q; Hai Y
    Medicine (Baltimore); 2017 Jun; 96(25):e7216. PubMed ID: 28640112
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Biomechanical effects of different bone cement diffusion patterns after vertebroplasty:finite element analysis].
    Yao G; Shen YX; Li M; Cai B
    Zhongguo Gu Shang; 2021 Aug; 34(8):732-7. PubMed ID: 34423616
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Finite element analysis of dynamic changes in spinal mechanics of osteoporotic lumbar fracture.
    Yan J; Liao Z; Yu Y
    Eur J Med Res; 2022 Aug; 27(1):142. PubMed ID: 35933368
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Three-dimensional finite element model of thoracolumbar spine with osteoporotic vertebral compression fracture].
    Fei Q; Li QJ; Yang Y; Li D; Tang H; Li JJ; Wang BQ; Wang YP
    Zhonghua Yi Xue Za Zhi; 2010 Nov; 90(41):2943-6. PubMed ID: 21211403
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Biomechanical analysis of sandwich vertebrae in osteoporotic patients: finite element analysis.
    Huang S; Zhou C; Zhang X; Tang Z; Liu L; Meng X; Xue C; Tang X
    Front Endocrinol (Lausanne); 2023; 14():1259095. PubMed ID: 37900139
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The stability of long-segment and short-segment fixation for treating severe burst fractures at the thoracolumbar junction in osteoporotic bone: A finite element analysis.
    Wu Y; Chen CH; Tsuang FY; Lin YC; Chiang CJ; Kuo YJ
    PLoS One; 2019; 14(2):e0211676. PubMed ID: 30716122
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Intradiscal cement leakage (ICL) increases the stress on adjacent vertebrae after kyphoplasty for osteoporotic vertebra compression fracture (OVCF): a finite-element study.
    Meng H; Li Q; Lin J; Yang Y; Fei Q
    Sci Rep; 2023 Sep; 13(1):15984. PubMed ID: 37749207
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Biomechanical effect on adjacent vertebra after percutaneous kyphoplasty with cement leakage into disc: a finite element analysis of thoracolumbar osteoporotic vertebral compression fracture].
    Fei Q; Li QJ; Li D; Yang Y; Tang H; Li JJ; Wang BQ; Wang YP
    Zhonghua Yi Xue Za Zhi; 2011 Jan; 91(1):51-5. PubMed ID: 21418964
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Finite element analysis of effect of different treatment methods on vertebral stability of osteoporotic vertebral compression fractures].
    Cheng M; Peng S; Jiang J; Deng L; Yang X; Zhao G
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2022 Dec; 36(12):1519-1523. PubMed ID: 36545861
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Biomechanical finite element analysis of vertebral column resection and posterior unilateral vertebral resection and reconstruction osteotomy.
    Han Y; Wang X; Wu J; Xu H; Zhang Z; Li K; Song Y; Miao J
    J Orthop Surg Res; 2021 Jan; 16(1):88. PubMed ID: 33509235
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Finite element study on three osteotomy methods for treating thoracolumbar osteoporotic fracture vertebral collapse complicated with neurological dysfunction.
    Long Z; Zhou J; Xiong L; Chen G; Wen J
    Medicine (Baltimore); 2024 Feb; 103(7):e36987. PubMed ID: 38363921
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Biomechanical study of different bone cement distribution on osteoporotic vertebral compression Fracture-A finite element analysis.
    Zhou C; Meng X; Huang S; Chen H; Zhou H; Liao Y; Tang Z; Zhang X; Li H; Sun W; Wang Y
    Heliyon; 2024 Mar; 10(5):e26726. PubMed ID: 38434291
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Use and evaluation of a semi-permeable mesh implant in vertebral augmentation for the treatment of painful osteoporotic vertebral compression fractures.
    Ortiz AO
    J Neurointerv Surg; 2016 Mar; 8(3):328-32. PubMed ID: 25586503
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Influence on adjacent lumbar bone density after strengthening of T12, L1 segment vertebral osteoporotic compression fracture by percutaneous vertebroplasty and percutaneous kyphoplasty].
    Zhang C; Zhu K; Zhou J; Zhou X; Niu G; Wu M; Shao C
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2013 Jul; 27(7):819-23. PubMed ID: 24063170
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.