182 related articles for article (PubMed ID: 35253728)
1. Prediction of the anastomosis angle of arteriovenous fistula in hemodialysis to standardize the surgical technique.
Shembekar SN; Zodpe DB; Padole PM
Biomed Mater Eng; 2022; 33(5):423-436. PubMed ID: 35253728
[TBL] [Abstract][Full Text] [Related]
2. Effect of anastomosis angle on the localization of disturbed flow in 'side-to-end' fistulae for haemodialysis access.
Ene-Iordache B; Cattaneo L; Dubini G; Remuzzi A
Nephrol Dial Transplant; 2013 Apr; 28(4):997-1005. PubMed ID: 22785110
[TBL] [Abstract][Full Text] [Related]
3. Assessing radiocephalic wrist arteriovenous fistulas of obtuse anastomosis using computational fluid dynamics and clinical application.
Lee J; Kim S; Kim SM; Song R; Kim HK; Park JS; Park SC
J Vasc Access; 2016 Nov; 17(6):512-520. PubMed ID: 27791257
[TBL] [Abstract][Full Text] [Related]
4. The Effect of Arterial Curvature on Blood Flow in Arterio-Venous Fistulae: Realistic Geometries and Pulsatile Flow.
Grechy L; Iori F; Corbett RW; Gedroyc W; Duncan N; Caro CG; Vincent PE
Cardiovasc Eng Technol; 2017 Sep; 8(3):313-329. PubMed ID: 28748414
[TBL] [Abstract][Full Text] [Related]
5. Detection of Abnormal Wall Shear Stress and Oscillatory Shear Index via Ultrasound Vector Flow Imaging as Possible Indicators for Arteriovenous Fistula Stenosis in Hemodialysis.
Ding J; Du Y; Zhao R; Yang Q; Zhu L; Tong Y; Wen C; Wang M
Ultrasound Med Biol; 2023 Aug; 49(8):1830-1836. PubMed ID: 37270353
[TBL] [Abstract][Full Text] [Related]
6. Analysis of Blood Flow Characteristics in a Model of a Mature Side-to-Side Arteriovenous Fistula.
Javadzadegan A; Myo Lwin N; Asyraf M; Simmons A; Barber T
Artif Organs; 2017 Nov; 41(11):E251-E262. PubMed ID: 28326557
[TBL] [Abstract][Full Text] [Related]
7. Analyses of hemodialysis arteriovenous fistula geometric configuration and its associations with maturation and reintervention.
He Y; Northrup H; Roy-Chaudhury P; Cheung AK; Berceli SA; Shiu YT
J Vasc Surg; 2021 May; 73(5):1778-1786.e1. PubMed ID: 33091518
[TBL] [Abstract][Full Text] [Related]
8. Computational fluid dynamic evaluation of the side-to-side anastomosis for arteriovenous fistula.
Hull JE; Balakin BV; Kellerman BM; Wrolstad DK
J Vasc Surg; 2013 Jul; 58(1):187-93.e1. PubMed ID: 23433819
[TBL] [Abstract][Full Text] [Related]
9. Experimental evaluation of a patient specific Brachio-Cephalic Arterio Venous Fistula (AVF): Velocity flow conditions under steady and pulsatile waveforms.
Alam N; Walsh M; Newport D
Med Eng Phys; 2022 Aug; 106():103834. PubMed ID: 35926957
[TBL] [Abstract][Full Text] [Related]
10. Disturbed flow in radial-cephalic arteriovenous fistulae for haemodialysis: low and oscillating shear stress locates the sites of stenosis.
Ene-Iordache B; Remuzzi A
Nephrol Dial Transplant; 2012 Jan; 27(1):358-68. PubMed ID: 21771751
[TBL] [Abstract][Full Text] [Related]
11. Variation of flow rate and angle of injected venous needle on influencing intimal hyperplasia at the venous anastomosis of the hemodialysis graft.
Yang L; Yin A; Liu W
Australas Phys Eng Sci Med; 2017 Mar; 40(1):239-248. PubMed ID: 28168585
[TBL] [Abstract][Full Text] [Related]
12. Intimal hyperplasia and hemodynamic factors in arterial bypass and arteriovenous grafts: a review.
Haruguchi H; Teraoka S
J Artif Organs; 2003; 6(4):227-35. PubMed ID: 14691664
[TBL] [Abstract][Full Text] [Related]
13. Hemodynamic impact of anastomosis size and angle in side-to-end arteriovenous fistulae: a computer analysis.
Van Canneyt K; Pourchez T; Eloot S; Guillame C; Bonnet A; Segers P; Verdonck P
J Vasc Access; 2010; 11(1):52-8. PubMed ID: 20119922
[TBL] [Abstract][Full Text] [Related]
14. A Review of the Hemodynamic Factors Believed to Contribute to Vascular Access Dysfunction.
Cunnane CV; Cunnane EM; Walsh MT
Cardiovasc Eng Technol; 2017 Sep; 8(3):280-294. PubMed ID: 28527110
[TBL] [Abstract][Full Text] [Related]
15. In vitro hemodynamic model of the arm arteriovenous circulation to study hemodynamics of native arteriovenous fistula and the distal revascularization and interval ligation procedure.
Varble N; Day S; Phillips D; Mix D; Schwarz K; Illig KA; Chandra A
J Vasc Surg; 2014 May; 59(5):1410-7. PubMed ID: 23845661
[TBL] [Abstract][Full Text] [Related]
16. Longitudinal assessment of hemodynamic endpoints in predicting arteriovenous fistula maturation.
Rajabi-Jagahrgh E; Krishnamoorthy MK; Roy-Chaudhury P; Succop P; Wang Y; Choe A; Banerjee RK
Semin Dial; 2013; 26(2):208-15. PubMed ID: 22892020
[TBL] [Abstract][Full Text] [Related]
17. Effects of wall shear stress in venous neointimal hyperplasia of arteriovenous fistulae.
Jia L; Wang L; Wei F; Yu H; Dong H; Wang B; Lu Z; Sun G; Chen H; Meng J; Li B; Zhang R; Bi X; Wang Z; Pang H; Jiang A
Nephrology (Carlton); 2015 May; 20(5):335-42. PubMed ID: 25581663
[TBL] [Abstract][Full Text] [Related]
18. Sequential venous anastomosis design to enhance patency of arterio-venous grafts for hemodialysis.
Kabinejadian F; Su B; Ghista DN; Ismail M; Kim S; Leo HL
Comput Methods Biomech Biomed Engin; 2017 Jan; 20(1):85-93. PubMed ID: 27328413
[TBL] [Abstract][Full Text] [Related]
19. Endothelial cell activation by hemodynamic shear stress derived from arteriovenous fistula for hemodialysis access.
Franzoni M; Cattaneo I; Longaretti L; Figliuzzi M; Ene-Iordache B; Remuzzi A
Am J Physiol Heart Circ Physiol; 2016 Jan; 310(1):H49-59. PubMed ID: 26497959
[TBL] [Abstract][Full Text] [Related]
20. Assessing the Disturbed Flow and the Transition to Turbulence in the Arteriovenous Fistula.
Stella S; Vergara C; Giovannacci L; Quarteroni A; Prouse G
J Biomech Eng; 2019 Oct; 141(10):. PubMed ID: 30968934
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]