These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

128 related articles for article (PubMed ID: 35256182)

  • 21. Accuracy of stereolithography additive casts used in a digital workflow.
    Al-Imam H; Gram M; Benetti AR; Gotfredsen K
    J Prosthet Dent; 2018 Apr; 119(4):580-585. PubMed ID: 28781073
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Additive Manufacturing: A Comparative Analysis of Dimensional Accuracy and Skin Texture Reproduction of Auricular Prostheses Replicas.
    Unkovskiy A; Spintzyk S; Axmann D; Engel EM; Weber H; Huettig F
    J Prosthodont; 2019 Feb; 28(2):e460-e468. PubMed ID: 29125215
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Accuracy and its impact on fit of injection molded, milled and additively manufactured occlusal splints.
    Wesemann C; Spies BC; Schaefer D; Adali U; Beuer F; Pieralli S
    J Mech Behav Biomed Mater; 2021 Feb; 114():104179. PubMed ID: 33189599
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Effect of Printing Direction on the Accuracy of 3D-Printed Dentures Using Stereolithography Technology.
    Hada T; Kanazawa M; Iwaki M; Arakida T; Soeda Y; Katheng A; Otake R; Minakuchi S
    Materials (Basel); 2020 Aug; 13(15):. PubMed ID: 32748815
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Stereolithography vs. Direct Light Processing for Rapid Manufacturing of Complete Denture Bases: An In Vitro Accuracy Analysis.
    Unkovskiy A; Schmidt F; Beuer F; Li P; Spintzyk S; Kraemer Fernandez P
    J Clin Med; 2021 Mar; 10(5):. PubMed ID: 33806627
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Evaluation of the adaptation of complete denture metal bases fabricated with dental CAD-CAM systems: An in vitro study.
    You SG; You SM; Kang SY; Bae SY; Kim JH
    J Prosthet Dent; 2021 Mar; 125(3):479-485. PubMed ID: 32276824
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Influence of additive manufacturing method and build angle on the accuracy of 3D-printed palatal plates.
    Dai J; Li P; Spintzyk S; Liu C; Xu S
    J Dent; 2023 May; 132():104449. PubMed ID: 36773740
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Evaluation of the accuracy (trueness and precision) of a maxillary trial denture according to the layer thickness: An in vitro study.
    You SM; You SG; Kang SY; Bae SY; Kim JH
    J Prosthet Dent; 2021 Jan; 125(1):139-145. PubMed ID: 32089361
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Evaluation on Surface Characteristics, Accuracy, and Dimensional Stability of Tooth Preparation Dies Fabricated by Conventional Gypsum and 3D-Printed Workflows.
    Tong XL; Ma CY; Yu N; Zhou HQ; Tan FB
    Int J Prosthodont; 2024 Feb; 0(0):1-32. PubMed ID: 38408132
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Surface roughness and marginal adaptation of stereolithography versus digital light processing three-dimensional printed resins: An
    Wadhwani V; Sivaswamy V; Rajaraman V
    J Indian Prosthodont Soc; 2022; 22(4):377-381. PubMed ID: 36511072
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Accuracy of 3-dimensional computer-aided manufactured single-tooth implant definitive casts.
    Buda M; Bratos M; Sorensen JA
    J Prosthet Dent; 2018 Dec; 120(6):913-918. PubMed ID: 29961627
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Additive Manufacturing Technologies Used for Processing Polymers: Current Status and Potential Application in Prosthetic Dentistry.
    Revilla-León M; Özcan M
    J Prosthodont; 2019 Feb; 28(2):146-158. PubMed ID: 29682823
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Accuracy Evaluation of Additively and Subtractively Fabricated Palatal Plate Orthodontic Appliances for Newborns and Infants-An In Vitro Study.
    Aretxabaleta M; Unkovskiy A; Koos B; Spintzyk S; Xepapadeas AB
    Materials (Basel); 2021 Jul; 14(15):. PubMed ID: 34361299
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Evaluation of the marginal fit of metal copings fabricated by using 3 different CAD-CAM techniques: Milling, stereolithography, and 3D wax printer.
    Khaledi AA; Farzin M; Akhlaghian M; Pardis S; Mir N
    J Prosthet Dent; 2020 Jul; 124(1):81-86. PubMed ID: 31672421
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Effect of additive manufacturing process and storage condition on the dimensional accuracy and stability of 3D-printed dental casts.
    Yousef H; Harris BT; Elathamna EN; Morton D; Lin WS
    J Prosthet Dent; 2022 Nov; 128(5):1041-1046. PubMed ID: 33785200
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Comparison of intraoral scanning and CBCT to generate digital and 3D-printed casts by fused deposition modeling and digital light processing.
    de Freitas BN; Mendonça LM; Cruvinel PB; de Lacerda TJ; Leite FGJ; Oliveira-Santos C; Tirapelli C
    J Dent; 2023 Jan; 128():104387. PubMed ID: 36496106
    [TBL] [Abstract][Full Text] [Related]  

  • 37. An In Vitro Evaluation of the Effect of 3D Printing Orientation on the Accuracy of Implant Surgical Templates Fabricated By Desktop Printer.
    Tahir N; Abduo J
    J Prosthodont; 2022 Dec; 31(9):791-798. PubMed ID: 35067993
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Position Accuracy of Implant Analogs on 3D Printed Polymer versus Conventional Dental Stone Casts Measured Using a Coordinate Measuring Machine.
    Revilla-León M; Gonzalez-Martín Ó; Pérez López J; Sánchez-Rubio JL; Özcan M
    J Prosthodont; 2018 Jul; 27(6):560-567. PubMed ID: 29148121
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Evaluation of intaglio surface trueness and margin quality of interim crowns in accordance with the build angle of stereolithography apparatus 3-dimensional printing.
    Yu BY; Son K; Lee KB
    J Prosthet Dent; 2021 Aug; 126(2):231-237. PubMed ID: 32807402
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Do hydrothermal aging and microwave sterilization affect the trueness of milled, additive manufactured and injection molded denture bases?
    Wemken G; Spies BC; Pieralli S; Adali U; Beuer F; Wesemann C
    J Mech Behav Biomed Mater; 2020 Nov; 111():103975. PubMed ID: 32781402
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.