BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

177 related articles for article (PubMed ID: 35257224)

  • 1. Robotic assistance for percutaneous needle insertion in the kidney: preclinical proof on a swine animal model.
    de Baere T; Roux C; Noel G; Delpla A; Deschamps F; Varin E; Tselikas L
    Eur Radiol Exp; 2022 Mar; 6(1):13. PubMed ID: 35257224
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Feasibility, safety and accuracy of a CT-guided robotic assistance for percutaneous needle placement in a swine liver model.
    Guiu B; De Baère T; Noel G; Ronot M
    Sci Rep; 2021 Mar; 11(1):5218. PubMed ID: 33664412
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Robotic CT-guided out-of-plane needle insertion: comparison of angle accuracy with manual insertion in phantom and measurement of distance accuracy in animals.
    Komaki T; Hiraki T; Kamegawa T; Matsuno T; Sakurai J; Matsuura R; Yamaguchi T; Sasaki T; Mitsuhashi T; Okamoto S; Uka M; Matsui Y; Iguchi T; Gobara H; Kanazawa S
    Eur Radiol; 2020 Mar; 30(3):1342-1349. PubMed ID: 31773299
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Robotic Insertion of Various Ablation Needles Under Computed Tomography Guidance: Accuracy in Animal Experiments.
    Hiraki T; Matsuno T; Kamegawa T; Komaki T; Sakurai J; Matsuura R; Yamaguchi T; Sasaki T; Iguchi T; Matsui Y; Gobara H; Kanazawa S
    Eur J Radiol; 2018 Aug; 105():162-167. PubMed ID: 30017274
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Phantom and Animal Study of a Robot-Assisted, CT-Guided Targeting System using Image-Only Navigation for Stereotactic Needle Insertion without Positional Sensors.
    Fong KY; Tan ASM; Bin Sulaiman MS; Leong SH; Ng KW; Too CW
    J Vasc Interv Radiol; 2022 Nov; 33(11):1416-1423.e4. PubMed ID: 35970505
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of a CT-Guided Robotic System for Precise Percutaneous Needle Insertion.
    Ben-David E; Shochat M; Roth I; Nissenbaum I; Sosna J; Goldberg SN
    J Vasc Interv Radiol; 2018 Oct; 29(10):1440-1446. PubMed ID: 29628297
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Robotically Driven CT-guided Needle Insertion: Preliminary Results in Phantom and Animal Experiments.
    Hiraki T; Kamegawa T; Matsuno T; Sakurai J; Kirita Y; Matsuura R; Yamaguchi T; Sasaki T; Mitsuhashi T; Komaki T; Masaoka Y; Matsui Y; Fujiwara H; Iguchi T; Gobara H; Kanazawa S
    Radiology; 2017 Nov; 285(2):454-461. PubMed ID: 28604237
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Robotic assistance for quick and accurate image-guided needle placement.
    Fong AJ; Stewart CL; Lafaro K; LaRocca CJ; Fong Y; Femino JD; Crawford B
    Updates Surg; 2021 Jun; 73(3):1197-1201. PubMed ID: 33394359
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Robot-Assisted Needle Insertion for CT-Guided Puncture: Experimental Study with a Phantom and Animals.
    Chen X; Yan Y; Li A; Wang T; Wang Y
    Cardiovasc Intervent Radiol; 2023 Jan; 46(1):128-135. PubMed ID: 36380153
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Robotic-assisted CT-guided percutaneous thermal ablation of abdominal tumors: An analysis of 41 patients.
    Bonnet B; de Baère T; Beunon P; Feddal A; Tselikas L; Deschamps F
    Diagn Interv Imaging; 2024 Jun; 105(6):227-232. PubMed ID: 38368177
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Ultrasound-guided needle insertion robotic system for percutaneous puncture.
    Chen S; Wang F; Lin Y; Shi Q; Wang Y
    Int J Comput Assist Radiol Surg; 2021 Mar; 16(3):475-484. PubMed ID: 33484429
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Robotic Assistance System for Cone-Beam Computed Tomography-Guided Percutaneous Needle Placement.
    Kostrzewa M; Rothfuss A; Pätz T; Kühne M; Schoenberg SO; Diehl SJ; Stallkamp J; Rathmann N
    Cardiovasc Intervent Radiol; 2022 Jan; 45(1):62-68. PubMed ID: 34414495
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Robotic needle insertion during computed tomography fluoroscopy-guided biopsy: prospective first-in-human feasibility trial.
    Hiraki T; Kamegawa T; Matsuno T; Sakurai J; Komaki T; Yamaguchi T; Tomita K; Uka M; Matsui Y; Iguchi T; Gobara H; Kanazawa S
    Eur Radiol; 2020 Feb; 30(2):927-933. PubMed ID: 31444597
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Zerobot®: A Remote-controlled Robot for Needle Insertion in CT-guided Interventional Radiology Developed at Okayama University.
    Hiraki T; Kamegawa T; Matsuno T; Komaki T; Sakurai J; Kanazawa S
    Acta Med Okayama; 2018 Dec; 72(6):539-546. PubMed ID: 30573907
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A robotic needle-positioning and guidance system for CT-guided puncture: Ex vivo results.
    Kettenbach J; Kara L; Toporek G; Fuerst M; Kronreif G
    Minim Invasive Ther Allied Technol; 2014 Oct; 23(5):271-8. PubMed ID: 24953817
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A semi-automated robotic system for percutaneous interventions.
    Siegfarth M; Lutz R; Iseke NC; Moviglia J; Sadi F; Stallkamp J
    Int J Comput Assist Radiol Surg; 2023 Sep; 18(9):1571-1575. PubMed ID: 37058232
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Accuracy analysis of robotic assistant needle placement for lateral skull base biopsy].
    Zhu JH; Wang J; Liu XJ; Guo CB
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2018 Aug; 53(8):519-523. PubMed ID: 30078263
    [No Abstract]   [Full Text] [Related]  

  • 18. Robotically Assisted CBCT-Guided Needle Insertions: Preliminary Results in a Phantom Model.
    Pfeil A; Cazzato RL; Barbé L; De Marini P; Chiang JB; Garnon J; Renaud P; Gangi A
    Cardiovasc Intervent Radiol; 2019 Feb; 42(2):283-288. PubMed ID: 30306204
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Accuracy and efficacy of percutaneous biopsy and ablation using robotic assistance under computed tomography guidance: a phantom study.
    Koethe Y; Xu S; Velusamy G; Wood BJ; Venkatesan AM
    Eur Radiol; 2014 Mar; 24(3):723-30. PubMed ID: 24220755
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Accuracy analysis of robotic assistant needle placement for trigeminal gasserian ganglion].
    Zhu JH; Wang J; Liu XJ; Guo CB
    Beijing Da Xue Xue Bao Yi Xue Ban; 2019 Oct; 51(5):973-976. PubMed ID: 31624409
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.