BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

160 related articles for article (PubMed ID: 35257314)

  • 1. The impact of target positioning error and tumor size on radiobiological parameters in robotic stereotactic radiosurgery for metastatic brain tumors.
    Takizawa T; Tanabe S; Nakano H; Utsunomiya S; Sakai M; Maruyama K; Takeuchi S; Nakano T; Ohta A; Kaidu M; Ishikawa H; Onda K
    Radiol Phys Technol; 2022 Jun; 15(2):135-146. PubMed ID: 35257314
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Radiobiological evaluation considering setup error on single-isocenter irradiation in stereotactic radiosurgery.
    Nakano H; Tanabe S; Sasamoto R; Takizawa T; Utsunomiya S; Sakai M; Nakano T; Ohta A; Kaidu M; Ishikawa H
    J Appl Clin Med Phys; 2021 Jul; 22(7):266-275. PubMed ID: 34151498
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Automated noncoplanar treatment planning strategy in stereotactic radiosurgery of multiple cranial metastases: HyperArc and CyberKnife dose distributions.
    Kadoya N; Abe Y; Kajikawa T; Ito K; Yamamoto T; Umezawa R; Chiba T; Katsuta Y; Takayama Y; Kato T; Kikuchi Y; Jingu K
    Med Dosim; 2019 Winter; 44(4):394-400. PubMed ID: 30827765
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Investigation of four-dimensional (4D) Monte Carlo dose calculation in real-time tumor tracking stereotatic body radiotherapy for lung cancers.
    Chan MK; Kwong DL; Ng SC; Tam EK; Tong AS
    Med Phys; 2012 Sep; 39(9):5479-87. PubMed ID: 22957615
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Assessment and quantification of patient set-up errors in nasopharyngeal cancer patients and their biological and dosimetric impact in terms of generalized equivalent uniform dose (gEUD), tumour control probability (TCP) and normal tissue complication probability (NTCP).
    Boughalia A; Marcie S; Fellah M; Chami S; Mekki F
    Br J Radiol; 2015 Jun; 88(1050):20140839. PubMed ID: 25882689
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Optimization of treatment isocenter location in single-isocenter LINAC-based stereotactic radiosurgery for management of multiple brain metastases.
    Cui T; Zhou Y; Yue NJ; Vergalasova I; Zhang Y; Zhu J; Nie K
    Med Phys; 2021 Dec; 48(12):7632-7640. PubMed ID: 34655249
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Dosimetric quality and delivery efficiency of robotic radiosurgery for brain metastases: Comparison with C-arm linear accelerator based plans.
    Zhang S; Yang R; Wang X
    J Appl Clin Med Phys; 2019 Nov; 20(11):104-110. PubMed ID: 31580532
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Radiobiological impact of dose calculation algorithms on biologically optimized IMRT lung stereotactic body radiation therapy plans.
    Liang X; Penagaricano J; Zheng D; Morrill S; Zhang X; Corry P; Griffin RJ; Han EY; Hardee M; Ratanatharathom V
    Radiat Oncol; 2016 Jan; 11():10. PubMed ID: 26800883
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison between the HyperArc™ technique and the CyberKnife® technique for stereotactic treatment of brain metastases.
    Guinement L; Salleron J; Buchheit I; Gérard K; Faivre JC; Royer P; Marchesi V
    Cancer Radiother; 2023 Apr; 27(2):136-144. PubMed ID: 36797159
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Helical TomoTherapy versus sterotactic Gamma Knife radiosurgery in the treatment of single and multiple brain tumors: a dosimetric comparison.
    Kumar T; Rakowski J; Zhao B; Alkhafaji M; Burmeister J; Austin T; Vlachaki M
    J Appl Clin Med Phys; 2010 Jul; 11(4):3245. PubMed ID: 21081881
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The dosimetric impact of the prescription isodose line (IDL) on the quality of robotic stereotactic radiosurgery (SRS) plans.
    Xu Q; Fan J; Grimm J; LaCouture T; Asbell S; Park JH; Kubicek G
    Med Phys; 2017 Dec; 44(12):6159-6165. PubMed ID: 29064585
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Dosimetric comparison of stereotactic body radiotherapy using 4D CT and multiphase CT images for treatment planning of lung cancer: evaluation of the impact on daily dose coverage.
    Wang L; Hayes S; Paskalev K; Jin L; Buyyounouski MK; Ma CC; Feigenberg S
    Radiother Oncol; 2009 Jun; 91(3):314-24. PubMed ID: 19111362
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Improved effectiveness of stereotactic radiosurgery in large brain metastases by individualized isotoxic dose prescription: an in silico study.
    Zindler JD; Schiffelers J; Lambin P; Hoffmann AL
    Strahlenther Onkol; 2018 Jun; 194(6):560-569. PubMed ID: 29349605
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Intracranial stereotactic radiosurgery with an adapted linear accelerator vs. robotic radiosurgery: Comparison of dosimetric treatment plan quality.
    Treuer H; Hoevels M; Luyken K; Visser-Vandewalle V; Wirths J; Kocher M; Ruge M
    Strahlenther Onkol; 2015 Jun; 191(6):470-6. PubMed ID: 25416146
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Radiobiological modeling of two stereotactic body radiotherapy schedules in patients with stage I peripheral non-small cell lung cancer.
    Huang BT; Lin Z; Lin PX; Lu JY; Chen CZ
    Oncotarget; 2016 Jun; 7(26):40746-40755. PubMed ID: 27203739
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Stereotactic body radiotherapy optimization to reduce the risk of carotid blowout syndrome using normal tissue complication probability objectives.
    Szalkowski G; Karakas Z; Cengiz M; Schreiber E; Das S; Yazici G; Ozyigit G; Mavroidis P
    J Appl Clin Med Phys; 2022 May; 23(5):e13563. PubMed ID: 35194924
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Dosimetric feasibility of the hybrid Magnetic Resonance Imaging (MRI)-linac System (MRL) for brain metastases: The impact of the magnetic field.
    Tseng CL; Eppinga W; Seravalli E; Hackett S; Brand E; Ruschin M; Lee YK; Atenafu EG; Sahgal A
    Radiother Oncol; 2017 Nov; 125(2):273-279. PubMed ID: 29079310
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Stereotactic radiosurgery with MLC-defined arcs: Verification of dosimetry, spatial accuracy, and end-to-end tests.
    Brezovich IA; Wu X; Popple RA; Covington E; Cardan R; Shen S; Fiveash J; Bredel M; Guthrie B
    J Appl Clin Med Phys; 2019 May; 20(5):84-98. PubMed ID: 30977297
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Dosimetric feasibility of brain stereotactic radiosurgery with a 0.35 T MRI-guided linac and comparison vs a C-arm-mounted linac.
    Slagowski JM; Redler G; Malin MJ; Cammin J; Lobb EC; Lee BH; Sethi A; Roeske JC; Flores-Martinez E; Stevens T; Yenice KM; Green O; Mutic S; Aydogan B
    Med Phys; 2020 Nov; 47(11):5455-5466. PubMed ID: 32996591
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Benefit of dosimetry distribution for patients with multiple brain metastases from non-small cell lung cancer by a Cyberknife stereotactic radiosurgery (SRS) system.
    Yu X; Wang Y; Yuan Z; Yu H; Song Y; Zhao L; Wang P
    BMC Cancer; 2020 Nov; 20(1):1144. PubMed ID: 33238967
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.