These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

313 related articles for article (PubMed ID: 35260715)

  • 1. A deep learning-driven low-power, accurate, and portable platform for rapid detection of COVID-19 using reverse-transcription loop-mediated isothermal amplification.
    Waheed W; Saylan S; Hassan T; Kannout H; Alsafar H; Alazzam A
    Sci Rep; 2022 Mar; 12(1):4132. PubMed ID: 35260715
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Multisite Clinical Validation of Isothermal Amplification-Based SARS-CoV-2 Detection Assays Using Different Sampling Strategies.
    Desai KT; Alfaro K; Mendoza L; Faron M; Mesich B; Maza M; Dominguez R; Valenzuela A; Acosta CD; Martínez M; Felix JC; Masch R; Smith JS; Gabrilovich S; Wu T; Plump M; Novetsky AP; Einstein MH; Douglas NC; Cremer M; Wentzensen N
    Microbiol Spectr; 2021 Oct; 9(2):e0084621. PubMed ID: 34668736
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Clinical testing on SARS-CoV-2 swab samples using reverse-transcription loop-mediated isothermal amplification (RT-LAMP).
    Lai MY; Bukhari FDM; Zulkefli NZ; Ismail I; Mustapa NI; Soh TST; Hassan AH; Peariasamy KM; Lee YL; Suppiah J; Thayan R; Isa MKM; Wahid NZA; Lau YL
    BMC Infect Dis; 2022 Aug; 22(1):697. PubMed ID: 35982419
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Portable and Label-Free Quantitative Loop-Mediated Isothermal Amplification (LF-qLamp) for Reliable COVID-19 Diagnostics in Three Minutes of Reaction Time: Arduino-Based Detection System Assisted by a pH Microelectrode.
    Alvarez MM; Bravo-González S; González-González E; Trujillo-de Santiago G
    Biosensors (Basel); 2021 Oct; 11(10):. PubMed ID: 34677342
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Development and Clinical Application of a Rapid and Sensitive Loop-Mediated Isothermal Amplification Test for SARS-CoV-2 Infection.
    Hu X; Deng Q; Li J; Chen J; Wang Z; Zhang X; Fang Z; Li H; Zhao Y; Yu P; Li W; Wang X; Li S; Zhang L; Hou T
    mSphere; 2020 Aug; 5(4):. PubMed ID: 32848011
    [TBL] [Abstract][Full Text] [Related]  

  • 6. SARS-CoV-2 detection by fluorescence loop-mediated isothermal amplification with and without RNA extraction.
    Taki K; Yokota I; Fukumoto T; Iwasaki S; Fujisawa S; Takahashi M; Negishi S; Hayasaka K; Sato K; Oguri S; Nishida M; Sugita J; Konno S; Saito T; Teshima T
    J Infect Chemother; 2021 Feb; 27(2):410-412. PubMed ID: 33214073
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A Portable RT-LAMP/CRISPR Machine for Rapid COVID-19 Screening.
    Rezaei M; Razavi Bazaz S; Morshedi Rad D; Shimoni O; Jin D; Rawlinson W; Ebrahimi Warkiani M
    Biosensors (Basel); 2021 Oct; 11(10):. PubMed ID: 34677325
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Extraction-free RT-LAMP to detect SARS-CoV-2 is less sensitive but highly specific compared to standard RT-PCR in 101 samples.
    Schellenberg JJ; Ormond M; Keynan Y
    J Clin Virol; 2021 Mar; 136():104764. PubMed ID: 33636553
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Performing point-of-care molecular testing for SARS-CoV-2 with RNA extraction and isothermal amplification.
    Garneret P; Coz E; Martin E; Manuguerra JC; Brient-Litzler E; Enouf V; González Obando DF; Olivo-Marin JC; Monti F; van der Werf S; Vanhomwegen J; Tabeling P
    PLoS One; 2021; 16(1):e0243712. PubMed ID: 33428641
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A highly effective reverse-transcription loop-mediated isothermal amplification (RT-LAMP) assay for the rapid detection of SARS-CoV-2 infection.
    Fowler VL; Armson B; Gonzales JL; Wise EL; Howson ELA; Vincent-Mistiaen Z; Fouch S; Maltby CJ; Grippon S; Munro S; Jones L; Holmes T; Tillyer C; Elwell J; Sowood A; de Peyer O; Dixon S; Hatcher T; Patrick H; Laxman S; Walsh C; Andreou M; Morant N; Clark D; Moore N; Houghton R; Cortes NJ; Kidd SP
    J Infect; 2021 Jan; 82(1):117-125. PubMed ID: 33271166
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Colorimetric Reverse Transcription-Loop-Mediated Isothermal Amplification Assay for Rapid Detection of SARS-CoV-2.
    Lai MY; Tang SN; Lau YL
    Am J Trop Med Hyg; 2021 Jun; 105(2):375-377. PubMed ID: 34129521
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Sequence-specific and multiplex detection of COVID-19 virus (SARS-CoV-2) using proofreading enzyme-mediated probe cleavage coupled with isothermal amplification.
    Ding S; Chen G; Wei Y; Dong J; Du F; Cui X; Huang X; Tang Z
    Biosens Bioelectron; 2021 Apr; 178():113041. PubMed ID: 33545551
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Electromechanical RT-LAMP device for portable SARS-CoV-2 detection.
    Tarim EA; Oksuz C; Karakuzu B; Appak O; Sayiner AA; Tekin HC
    Talanta; 2023 Mar; 254():124190. PubMed ID: 36521325
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A point-of-care SARS-CoV-2 test based on reverse transcription loop-mediated isothermal amplification without RNA extraction with diagnostic performance same as RT-PCR.
    Odiwuor N; Xiong J; Ogolla F; Hong W; Li X; Khan FM; Wang N; Yu J; Wei H
    Anal Chim Acta; 2022 Apr; 1200():339590. PubMed ID: 35256137
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A colorimetric reverse transcription-loop mediated isothermal amplification (RT-LAMP) method for the rapid detection of SARS-CoV-2 in Thailand.
    Bhakdeenuan P; Bunchoo S; Klayut K; Srisungngam S; Suphan O; Kongthap I; Suphankong S; Phetsuksiri B; Uppapong B; Rudeeaneksin J
    Trop Biomed; 2024 Mar; 41(1):64-69. PubMed ID: 38852135
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Colorimetric reverse transcription loop-mediated isothermal amplification (RT-LAMP) as a visual diagnostic platform for the detection of the emerging coronavirus SARS-CoV-2.
    Nawattanapaiboon K; Pasomsub E; Prombun P; Wongbunmak A; Jenjitwanich A; Mahasupachai P; Vetcho P; Chayrach C; Manatjaroenlap N; Samphaongern C; Watthanachockchai T; Leedorkmai P; Manopwisedjaroen S; Akkarawongsapat R; Thitithanyanont A; Phanchana M; Panbangred W; Chauvatcharin S; Srikhirin T
    Analyst; 2021 Jan; 146(2):471-477. PubMed ID: 33165486
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Paper-based loop-mediated isothermal amplification and CRISPR integrated platform for on-site nucleic acid testing of pathogens.
    Sen A; Masetty M; Weerakoon S; Morris C; Yadav JS; Apewokin S; Trannguyen J; Broom M; Priye A
    Biosens Bioelectron; 2024 Aug; 257():116292. PubMed ID: 38653014
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Essential properties and pitfalls of colorimetric Reverse Transcription Loop-mediated Isothermal Amplification as a point-of-care test for SARS-CoV-2 diagnosis.
    de Oliveira Coelho B; Sanchuki HBS; Zanette DL; Nardin JM; Morales HMP; Fornazari B; Aoki MN; Blanes L
    Mol Med; 2021 Mar; 27(1):30. PubMed ID: 33771097
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Preliminary optimisation of a simplified sample preparation method to permit direct detection of SARS-CoV-2 within saliva samples using reverse-transcription loop-mediated isothermal amplification (RT-LAMP).
    Howson ELA; Kidd SP; Armson B; Goring A; Sawyer J; Cassar C; Cross D; Lewis T; Hockey J; Rivers S; Cawthraw S; Banyard A; Anderson P; Rahou S; Andreou M; Morant N; Clark D; Walsh C; Laxman S; Houghton R; Slater-Jefferies J; Costello P; Brown I; Cortes N; Godfrey KM; Fowler VL
    J Virol Methods; 2021 Mar; 289():114048. PubMed ID: 33358911
    [TBL] [Abstract][Full Text] [Related]  

  • 20. opvCRISPR: One-pot visual RT-LAMP-CRISPR platform for SARS-cov-2 detection.
    Wang R; Qian C; Pang Y; Li M; Yang Y; Ma H; Zhao M; Qian F; Yu H; Liu Z; Ni T; Zheng Y; Wang Y
    Biosens Bioelectron; 2021 Jan; 172():112766. PubMed ID: 33126177
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 16.