These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

162 related articles for article (PubMed ID: 35265785)

  • 21. Unicortical versus bicortical locked plate fixation in midshaft clavicle fractures.
    Bravman JT; Taylor ML; Baldini T; Vidal AF
    Orthopedics; 2015 May; 38(5):e411-6. PubMed ID: 25970369
    [TBL] [Abstract][Full Text] [Related]  

  • 22. No Difference in Risk of Implant Removal Between Orthogonal Mini-fragment and Single Small-fragment Plating of Midshaft Clavicle Fractures in a Military Population: A Preliminary Study.
    Lee C; Feaker DA; Ostrofe AA; Smith CS
    Clin Orthop Relat Res; 2020 Apr; 478(4):741-749. PubMed ID: 32229745
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Bicortical versus unicortical fixation of plated clavicular fractures: A biomechanical study.
    Zaidenberg EE; Voor M; Pereira E; Rossi LA; Zaidenberg CR
    Shoulder Elbow; 2021 Aug; 13(4):426-432. PubMed ID: 34394740
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Numerical simulation and biomechanical analysis of locking screw caps on clavicle locking plates.
    Kim DG; Min Kim S; Kim Y
    Medicine (Baltimore); 2022 Jul; 101(30):e29319. PubMed ID: 35905263
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Finite element analysis comparison between superior clavicle locking plate with and without screw holes above fracture zone in midshaft clavicular fracture.
    Pengrung N; Lakdee N; Puncreobutr C; Lohwongwatana B; Sa-Ngasoongsong P
    BMC Musculoskelet Disord; 2019 Oct; 20(1):465. PubMed ID: 31640668
    [TBL] [Abstract][Full Text] [Related]  

  • 26. The application of inverted lateral clavicle locking compression plate for medial clavicle fractures: biomechanical study and clinical implementation.
    Kritsaneephaiboon A; Jitprapaikulsarn S; Chantarapanich N; Klabklay P; Gromprasit A; Patamamongkonchai C; Dissaneewate P
    Eur J Orthop Surg Traumatol; 2024 Apr; 34(3):1465-1478. PubMed ID: 38245617
    [TBL] [Abstract][Full Text] [Related]  

  • 27. The comminuted midshaft clavicle fracture: a biomechanical evaluation of plating methods.
    Taylor PR; Day RE; Nicholls RL; Rasmussen J; Yates PJ; Stoffel KK
    Clin Biomech (Bristol, Avon); 2011 Jun; 26(5):491-6. PubMed ID: 21257237
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Bioabsorbable plating in the treatment of pediatric clavicle fractures: A biomechanical and clinical analysis.
    Osborn EJ; Farnsworth CL; Doan JD; Edmonds EW
    Clin Biomech (Bristol, Avon); 2018 Jun; 55():94-99. PubMed ID: 29727767
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Biomechanical Evaluation of Dual Plate Configurations for Femoral Shaft Fracture Fixation.
    El Beaino M; Morris RP; Lindsey RW; Gugala Z
    Biomed Res Int; 2019; 2019():5958631. PubMed ID: 31183369
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Anteroinferior 2.7-mm versus 3.5-mm plating of the clavicle: A biomechanical study.
    Pulos N; Yoon RS; Shetye S; Hast MW; Liporace F; Donegan DJ
    Injury; 2016 Aug; 47(8):1642-6. PubMed ID: 27319390
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Surgical fixation of midshaft clavicle fractures: A systematic review of biomechanical studies.
    Hulsmans MH; van Heijl M; Houwert RM; Burger BJ; Verleisdonk EJM; Veeger DJ; van der Meijden OA
    Injury; 2018 Apr; 49(4):753-765. PubMed ID: 29523350
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Do Transcortical Screws in a Locking Plate Construct Improve the Stiffness in the Fixation of Vancouver B1 Periprosthetic Femur Fractures? A Biomechanical Analysis of 2 Different Plating Constructs.
    Lochab J; Carrothers A; Wong E; McLachlin S; Aldebeyan W; Jenkinson R; Whyne C; Nousiainen MT
    J Orthop Trauma; 2017 Jan; 31(1):15-20. PubMed ID: 28002219
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Biomechanical comparison of three different plate configurations for comminuted clavicle midshaft fracture fixation.
    Uzer G; Yildiz F; Batar S; Bozdag E; Kuduz H; Bilsel K
    J Shoulder Elbow Surg; 2017 Dec; 26(12):2200-2205. PubMed ID: 29037534
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Midshaft Fractures of the Clavicle: A Meta-analysis Comparing Surgical Fixation Using Anteroinferior Plating Versus Superior Plating.
    Nourian A; Dhaliwal S; Vangala S; Vezeridis PS
    J Orthop Trauma; 2017 Sep; 31(9):461-467. PubMed ID: 28708779
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Outcomes and complications after dual plate vs. single plate fixation of displaced mid-shaft clavicle fractures: A systematic review and meta-analysis.
    You DZ; Krzyzaniak H; Kendal JK; Martin CR; Schneider PS
    J Clin Orthop Trauma; 2021 Jun; 17():261-266. PubMed ID: 33936947
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Plate selection for fixation of extra-articular distal humerus fractures: a biomechanical comparison of three different implants.
    Scolaro JA; Hsu JE; Svach DJ; Mehta S
    Injury; 2014 Dec; 45(12):2040-4. PubMed ID: 25249244
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Reconstruction plates for stabilization of mid-shaft clavicle fractures: differences between nonlocked and locked plates in two different positions.
    Robertson C; Celestre P; Mahar A; Schwartz A
    J Shoulder Elbow Surg; 2009; 18(2):204-9. PubMed ID: 19111476
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Conceptual finite element study for comparison among superior, anterior, and spiral clavicle plate fixations for midshaft clavicle fracture.
    Huang TL; Chen WC; Lin KJ; Tsai CL; Lin KP; Wei HW
    Med Eng Phys; 2016 Oct; 38(10):1070-5. PubMed ID: 27423702
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Dual plating of humeral shaft fractures: orthogonal plates biomechanically outperform side-by-side plates.
    Kosmopoulos V; Nana AD
    Clin Orthop Relat Res; 2014 Apr; 472(4):1310-7. PubMed ID: 24218163
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Are two plates better than one? A systematic review of dual plating for acute midshaft clavicle fractures.
    Sheth U; Fernandez CE; Morgan AM; Henry P; Nam D
    Shoulder Elbow; 2022 Oct; 14(5):500-509. PubMed ID: 36199514
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.