These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

153 related articles for article (PubMed ID: 35271020)

  • 1. A Data-Driven Model with Feedback Calibration Embedded Blood Pressure Estimator Using Reflective Photoplethysmography.
    Chen JW; Huang HK; Fang YT; Lin YT; Li SZ; Chen BW; Lo YC; Chen PC; Wang CF; Chen YY
    Sensors (Basel); 2022 Feb; 22(5):. PubMed ID: 35271020
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Nocturnal Blood Pressure Estimation from Sleep Plethysmography Using Machine Learning.
    Yilmaz G; Lyu X; Ong JL; Ling LH; Penzel T; Yeo BTT; Chee MWL
    Sensors (Basel); 2023 Sep; 23(18):. PubMed ID: 37765988
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [2013 Ambulatory blood pressure monitoring recommendations for the diagnosis of adult hypertension, assessment of cardiovascular and other hypertension-associated risk, and attainment of therapeutic goals (summary). Joint recommendations from the International Society for Chronobiology (ISC), American Association of Medical Chronobiology and Chronotherapeutics (AAMCC), Spanish Society of Applied Chronobiology, Chronotherapy, and Vascular Risk (SECAC), Spanish Society of Atherosclerosis (SEA), and Romanian Society of Internal Medicine (RSIM)].
    Hermida RC; Smolensky MH; Ayala DE; Portaluppi F; Crespo JJ; Fabbian F; Haus E; Manfredini R; Mojón A; Moyá A; Piñeiro L; Ríos MT; Otero A; Balan H; Fernández JR
    Clin Investig Arterioscler; 2013; 25(2):74-82. PubMed ID: 23849214
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Accuracy and User Acceptability of 24-hour Ambulatory Blood Pressure Monitoring by a Prototype Cuffless Multi-Sensor Device Compared to a Conventional Oscillometric Device.
    Heimark S; Hove C; Stepanov A; Boysen ES; Gløersen Ø; Bøtke-Rasmussen KG; Gravdal HJ; Narayanapillai K; Fadl Elmula FEM; Seeberg TM; Larstorp ACK; Waldum-Grevbo B
    Blood Press; 2023 Dec; 32(1):2274595. PubMed ID: 37885101
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Status of ambulatory blood pressure monitoring and home blood pressure monitoring for the diagnosis and management of hypertension in the US: an up-to-date review.
    Cepeda M; Pham P; Shimbo D
    Hypertens Res; 2023 Mar; 46(3):620-629. PubMed ID: 36604475
    [TBL] [Abstract][Full Text] [Related]  

  • 6. PPG-Based Blood Pressure Monitoring by Pulse Wave Analysis: Calibration Parameters are Stable for Three Months.
    Proenca M; Bonnier G; Ferrario D; Verjus C; Lemay M
    Annu Int Conf IEEE Eng Med Biol Soc; 2019 Jul; 2019():5560-5563. PubMed ID: 31947115
    [TBL] [Abstract][Full Text] [Related]  

  • 7. KD-Informer: A Cuff-Less Continuous Blood Pressure Waveform Estimation Approach Based on Single Photoplethysmography.
    Ma C; Zhang P; Song F; Sun Y; Fan G; Zhang T; Feng Y; Zhang G
    IEEE J Biomed Health Inform; 2023 May; 27(5):2219-2230. PubMed ID: 35700247
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A comparative trial of blood pressure monitoring in a self-care kiosk, in office, and with ambulatory blood pressure monitoring.
    Nilsson G; Lindam A
    BMC Cardiovasc Disord; 2024 Jan; 24(1):27. PubMed ID: 38172659
    [TBL] [Abstract][Full Text] [Related]  

  • 9. An Estimation Method of Continuous Non-Invasive Arterial Blood Pressure Waveform Using Photoplethysmography: A U-Net Architecture-Based Approach.
    Athaya T; Choi S
    Sensors (Basel); 2021 Mar; 21(5):. PubMed ID: 33800106
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Blood Pressure Estimation Using Photoplethysmography Only: Comparison between Different Machine Learning Approaches.
    Khalid SG; Zhang J; Chen F; Zheng D
    J Healthc Eng; 2018; 2018():1548647. PubMed ID: 30425819
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Continuous cuffless blood pressure monitoring using photoplethysmography-based PPG2BP-net for high intrasubject blood pressure variations.
    Joung J; Jung CW; Lee HC; Chae MJ; Kim HS; Park J; Shin WY; Kim C; Lee M; Choi C
    Sci Rep; 2023 May; 13(1):8605. PubMed ID: 37244974
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Estimate of nocturnal blood pressure and detection of non-dippers based on clinical or ambulatory monitoring in the inpatient setting.
    Xu T; Zhang Y; Tan X
    BMC Cardiovasc Disord; 2013 May; 13():37. PubMed ID: 23692688
    [TBL] [Abstract][Full Text] [Related]  

  • 13. DeepCNAP: A Deep Learning Approach for Continuous Noninvasive Arterial Blood Pressure Monitoring Using Photoplethysmography.
    Kim DK; Kim YT; Kim H; Kim DJ
    IEEE J Biomed Health Inform; 2022 Aug; 26(8):3697-3707. PubMed ID: 35511844
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A novel method for continuous blood pressure estimation based on a single-channel photoplethysmogram signal.
    Hu Q; Deng X; Wang A; Yang C
    Physiol Meas; 2021 Jan; 41(12):125009. PubMed ID: 33166940
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A Continuous Blood Pressure Estimation Method Using Photoplethysmography by GRNN-Based Model.
    Li Z; He W
    Sensors (Basel); 2021 Oct; 21(21):. PubMed ID: 34770514
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A Comparison of Wearable Tonometry, Photoplethysmography, and Electrocardiography for Cuffless Measurement of Blood Pressure in an Ambulatory Setting.
    Mieloszyk R; Twede H; Lester J; Wander J; Basu S; Cohn G; Smith G; Morris D; Gupta S; Tan D; Villar N; Wolf M; Malladi S; Mickelson M; Ryan L; Kim L; Kepple J; Kirchner S; Wampler E; Terada R; Robinson J; Paulsen R; Saponas TS
    IEEE J Biomed Health Inform; 2022 Jul; 26(7):2864-2875. PubMed ID: 35201992
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Wearable Cuff-Less Blood Pressure Estimation at Home via Pulse Transit Time.
    Ganti VG; Carek AM; Nevius BN; Heller JA; Etemadi M; Inan OT
    IEEE J Biomed Health Inform; 2021 Jun; 25(6):1926-1937. PubMed ID: 32881697
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Upper-Arm Photoplethysmographic Sensor with One-Time Calibration for Long-Term Blood Pressure Monitoring.
    Wang CF; Wang TY; Kuo PH; Wang HL; Li SZ; Lin CM; Chan SC; Liu TY; Lo YC; Lin SH; Chen YY
    Biosensors (Basel); 2023 Feb; 13(3):. PubMed ID: 36979533
    [TBL] [Abstract][Full Text] [Related]  

  • 19. 2013 ambulatory blood pressure monitoring recommendations for the diagnosis of adult hypertension, assessment of cardiovascular and other hypertension-associated risk, and attainment of therapeutic goals.
    ; ; ; ; ; Hermida RC; Smolensky MH; Ayala DE; Portaluppi F
    Chronobiol Int; 2013 Apr; 30(3):355-410. PubMed ID: 23517220
    [TBL] [Abstract][Full Text] [Related]  

  • 20.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 8.