234 related articles for article (PubMed ID: 35272774)
1. Risk Assessment of Coronary Obstruction During Transcatheter Aortic Valve Replacement: Insights From Post-BASILICA Computed Tomography.
Kitamura M; Wilde J; Dumpies O; Richter I; Obradovic D; Krieghoff C; Gohmann RF; Majunke N; Desch S; Gutberlet M; Borger M; Marwan M; Thiele H; Holzhey D; Abdel-Wahab M
JACC Cardiovasc Interv; 2022 Mar; 15(5):496-507. PubMed ID: 35272774
[TBL] [Abstract][Full Text] [Related]
2. The BASILICA Trial: Prospective Multicenter Investigation of Intentional Leaflet Laceration to Prevent TAVR Coronary Obstruction.
Khan JM; Greenbaum AB; Babaliaros VC; Rogers T; Eng MH; Paone G; Leshnower BG; Reisman M; Satler L; Waksman R; Chen MY; Stine AM; Tian X; Dvir D; Lederman RJ
JACC Cardiovasc Interv; 2019 Jul; 12(13):1240-1252. PubMed ID: 31202947
[TBL] [Abstract][Full Text] [Related]
3. Coronary ostial eccentricity in severe aortic stenosis: Guidance for BASILICA transcatheter leaflet laceration.
Komatsu I; Leipsic J; Webb JG; Blanke P; Mackensen GB; Don CW; McCabe JM; Rumer C; Tan CW; Levin DB; Ramos M; Aldea GS; Reisman M; Wijeysundera HC; Radhakrishnan S; Sathananthan J; Piazza N; Kornowski R; Dvir D
J Cardiovasc Comput Tomogr; 2020; 14(6):516-519. PubMed ID: 32199758
[TBL] [Abstract][Full Text] [Related]
4. Transcatheter Laceration of Aortic Leaflets to Prevent Coronary Obstruction During Transcatheter Aortic Valve Replacement: Concept to First-in-Human.
Khan JM; Dvir D; Greenbaum AB; Babaliaros VC; Rogers T; Aldea G; Reisman M; Mackensen GB; Eng MHK; Paone G; Wang DD; Guyton RA; Devireddy CM; Schenke WH; Lederman RJ
JACC Cardiovasc Interv; 2018 Apr; 11(7):677-689. PubMed ID: 29622147
[TBL] [Abstract][Full Text] [Related]
5. Risk of Coronary Obstruction Due to Sinus Sequestration in Redo Transcatheter Aortic Valve Replacement.
Ochiai T; Oakley L; Sekhon N; Komatsu I; Flint N; Kaewkes D; Yoon SH; Raschpichler M; Patel V; Tiwana R; Enta Y; Mahani S; Kim Y; Stegic J; Chakravarty T; Nakamura M; Cheng W; Makkar R
JACC Cardiovasc Interv; 2020 Nov; 13(22):2617-2627. PubMed ID: 33213747
[TBL] [Abstract][Full Text] [Related]
6. Preventing Coronary Obstruction During Transcatheter Aortic Valve Replacement: From Computed Tomography to BASILICA.
Lederman RJ; Babaliaros VC; Rogers T; Khan JM; Kamioka N; Dvir D; Greenbaum AB
JACC Cardiovasc Interv; 2019 Jul; 12(13):1197-1216. PubMed ID: 31272666
[TBL] [Abstract][Full Text] [Related]
7. Distribution of C-arm projections in native and bioprosthetic aortic valves cusps: Implication for BASILICA procedures.
Komatsu I; Tang GHL; Leipsic J; Webb JG; Blanke P; Mackensen GB; Kitamura M; Wolak A; Don CW; McCabe JM; Rumer C; Tan CW; Levin DB; Ramos M; Aldea GS; Reisman M; Wijeysundera HC; Radhakrishnan S; Sathananthan J; Piazza N; Kornowski R; Abdel-Wahab M; Dvir D
Catheter Cardiovasc Interv; 2021 Mar; 97(4):E580-E587. PubMed ID: 32894804
[TBL] [Abstract][Full Text] [Related]
8. Chimney Stenting vs BASILICA for Prevention of Acute Coronary Obstruction During Transcatheter Aortic Valve Replacement.
Mangieri A; Richter I; Gitto M; Abdelhafez A; Bedogni F; Lanz J; Montorfano M; Unbehaun A; Giannini F; Nerla R; Taramasso M; Ielasi A; Rudolph T; Ferlini M; Ribichini F; Poletti E; Latib A; Colombo A; Van Mieghem NM; Thiele H; Abdel-Wahab M
JACC Cardiovasc Interv; 2024 Mar; 17(6):742-752. PubMed ID: 38538170
[TBL] [Abstract][Full Text] [Related]
9. Pachyderm-Shape Guiding Catheters to Simplify BASILICA Leaflet Traversal.
Lisko JC; Babaliaros VC; Lederman RJ; Khan JM; Rogers T; Greenbaum AB
Cardiovasc Revasc Med; 2019 Sep; 20(9):782-785. PubMed ID: 31257172
[TBL] [Abstract][Full Text] [Related]
10. CoreValve bioprosthesis dysfunction treated with a Sapien 3 valve-in-valve transcatheter aortic valve replacement and BASILICA technique.
Sharma RK; Tuttle MK; Poulin MF; Laham RJ
Catheter Cardiovasc Interv; 2021 Aug; 98(2):403-406. PubMed ID: 33595150
[TBL] [Abstract][Full Text] [Related]
11. Equipment entrapment during redo-TAVR with successful BASILICA procedure.
Qureshi WT; Parker M; Walker J; Kakouros N
Catheter Cardiovasc Interv; 2021 Aug; 98(2):E320-E323. PubMed ID: 33484070
[TBL] [Abstract][Full Text] [Related]
12. Bioprosthetic aortic valve leaflet disruption with high energy electrocautery to prevent coronary artery obstruction during valve-in-valve transcatheter aortic valve replacement.
Nelson BC; Chadderdon S; Song H; Zahr FE
Catheter Cardiovasc Interv; 2019 Jan; 93(1):164-168. PubMed ID: 30298684
[TBL] [Abstract][Full Text] [Related]
13. Impact of Leaflet Laceration on Transcatheter Aortic Valve-in-Valve Washout: BASILICA to Solve Neosinus and Sinus Stasis.
Hatoum H; Maureira P; Lilly S; Dasi LP
JACC Cardiovasc Interv; 2019 Jul; 12(13):1229-1237. PubMed ID: 31272669
[TBL] [Abstract][Full Text] [Related]
14. Feasibility of Coronary Access and Aortic Valve Reintervention in Low-Risk TAVR Patients.
Rogers T; Greenspun BC; Weissman G; Torguson R; Craig P; Shults C; Gordon P; Ehsan A; Wilson SR; Goncalves J; Levitt R; Hahn C; Parikh P; Bilfinger T; Butzel D; Buchanan S; Hanna N; Garrett R; Buchbinder M; Asch F; Garcia-Garcia HM; Okubagzi P; Ben-Dor I; Satler LF; Waksman R
JACC Cardiovasc Interv; 2020 Mar; 13(6):726-735. PubMed ID: 32192693
[TBL] [Abstract][Full Text] [Related]
15. Coronary Access After TAVR With a Self-Expanding Bioprosthesis: Insights From Computed Tomography.
Abdelghani M; Landt M; Traboulsi H; Becker B; Richardt G
JACC Cardiovasc Interv; 2020 Mar; 13(6):709-722. PubMed ID: 32192691
[TBL] [Abstract][Full Text] [Related]
16. Bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction technique in transcatheter aortic valve-in-valve procedures: a single-center initial experience.
Tagliari AP; Miura M; Gavazzoni M; Haager PK; Russo G; Pozzoli A; Zuber M; Jörg L; Rickli H; Gennari M; Maisano F; Taramasso M
J Cardiovasc Med (Hagerstown); 2021 Mar; 22(3):212-221. PubMed ID: 32890234
[TBL] [Abstract][Full Text] [Related]
17. Coronary Access After TAVR.
Ochiai T; Chakravarty T; Yoon SH; Kaewkes D; Flint N; Patel V; Mahani S; Tiwana R; Sekhon N; Nakamura M; Cheng W; Makkar R
JACC Cardiovasc Interv; 2020 Mar; 13(6):693-705. PubMed ID: 32192689
[TBL] [Abstract][Full Text] [Related]
18. Risk of Coronary Obstruction and Feasibility of Coronary Access After Repeat Transcatheter Aortic Valve Replacement With the Self-Expanding Evolut Valve: A Computed Tomography Simulation Study.
Forrestal BJ; Case BC; Yerasi C; Shea C; Torguson R; Zhang C; Ben-Dor I; Deksissa T; Ali S; Satler LF; Shults C; Weissman G; Wang JC; Khan JM; Waksman R; Rogers T
Circ Cardiovasc Interv; 2020 Dec; 13(12):e009496. PubMed ID: 33272031
[TBL] [Abstract][Full Text] [Related]
19. Bioprosthetic Valve Leaflet Displacement During Valve-in-Valve Intervention: An Ex Vivo Bench Study.
Hensey M; Sellers S; Sathananthan J; Lai A; Landes U; Alkhodair A; McManus B; Cheung A; Wood D; Blanke P; Leipsic J; Ye J; Webb J
JACC Cardiovasc Interv; 2020 Mar; 13(6):667-678. PubMed ID: 32113932
[TBL] [Abstract][Full Text] [Related]
20. Systematic use of intentional leaflet laceration to prevent TAVI-induced coronary obstruction: feasibility and early clinical outcomes of the BASILICA technique.
Kitamura M; Majunke N; Holzhey D; Desch S; Bani Hani A; Krieghoff C; Gutberlet M; Protsyk V; Ender J; Borger MA; Dvir D; Thiele H; Abdel-Wahab M
EuroIntervention; 2020 Oct; 16(8):682-690. PubMed ID: 32597392
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]