These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

168 related articles for article (PubMed ID: 35273303)

  • 1. Multi-dimensional-double-spiral (MDDS) inertial microfluidic platform for sperm isolation directly from the raw semen sample.
    Jeon H; Cremers C; Le D; Abell J; Han J
    Sci Rep; 2022 Mar; 12(1):4212. PubMed ID: 35273303
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Microfluidic sorting selects sperm for clinical use with reduced DNA damage compared to density gradient centrifugation with swim-up in split semen samples.
    Quinn MM; Jalalian L; Ribeiro S; Ona K; Demirci U; Cedars MI; Rosen MP
    Hum Reprod; 2018 Aug; 33(8):1388-1393. PubMed ID: 30007319
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Fully-automated and field-deployable blood leukocyte separation platform using multi-dimensional double spiral (MDDS) inertial microfluidics.
    Jeon H; Jundi B; Choi K; Ryu H; Levy BD; Lim G; Han J
    Lab Chip; 2020 Sep; 20(19):3612-3624. PubMed ID: 32990714
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The Effects of Microfluidic Sperm Sorting, Density Gradient and Swim-up Methods on Semen Oxidation Reduction Potential.
    Gode F; Gürbüz AS; Tamer B; Pala I; Isik AZ
    Urol J; 2020 May; 17(4):397-401. PubMed ID: 32478404
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Cross flow coupled with inertial focusing for separation of human sperm cells from semen and simulated TESE samples.
    Rahi A; Kazemi M; Pishbin E; Karimi S; Nazarian H
    Analyst; 2021 Nov; 146(23):7230-7239. PubMed ID: 34724697
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Rheotaxis-based microfluidic device for selecting sperm from samples infected with a virus.
    Ataei A; Kabir MA; Lau AWC; Asghar W
    F S Sci; 2021 Nov; 2(4):376-382. PubMed ID: 35559860
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A novel microfluidic system to separate sperm using spermatozoa inherent motion and inertial effect.
    Ghassemi Panah A; Zabetian Targhi M; Heydari A; Halvaei I
    J Biomech; 2022 Sep; 142():111256. PubMed ID: 35985073
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Progressive bovine sperm separation using parallelized microchamber-based microfluidics.
    Yaghoobi M; Azizi M; Mokhtare A; Abbaspourrad A
    Lab Chip; 2021 Jul; 21(14):2791-2804. PubMed ID: 34105565
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Differential impact of four sperm preparation techniques on sperm motility, morphology, DNA fragmentation, acrosome status, oxidative stress, and mitochondrial activity: A prospective study.
    Raad G; Bakos HW; Bazzi M; Mourad Y; Fakih F; Shayya S; Mchantaf L; Fakih C
    Andrology; 2021 Sep; 9(5):1549-1559. PubMed ID: 33999521
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Selection of healthy sperm based on positive rheotaxis using a microfluidic device.
    Sharma S; Kabir MA; Asghar W
    Analyst; 2022 Apr; 147(8):1589-1597. PubMed ID: 35293399
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A novel microfluidic device with parallel channels for sperm separation using spermatozoa intrinsic behaviors.
    Heydari A; Zabetian Targhi M; Halvaei I; Nosrati R
    Sci Rep; 2023 Jan; 13(1):1185. PubMed ID: 36681743
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Isolation of motile spermatozoa from semen samples using microfluidics.
    Schuster TG; Cho B; Keller LM; Takayama S; Smith GD
    Reprod Biomed Online; 2003; 7(1):75-81. PubMed ID: 12930579
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Separation efficiency of a microfluidic sperm sorter to minimize sperm DNA damage.
    Shirota K; Yotsumoto F; Itoh H; Obama H; Hidaka N; Nakajima K; Miyamoto S
    Fertil Steril; 2016 Feb; 105(2):315-21.e1. PubMed ID: 26551440
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Separation of sperm cells from samples containing high concentrations of white blood cells using a spiral channel.
    Son J; Samuel R; Gale BK; Carrell DT; Hotaling JM
    Biomicrofluidics; 2017 Sep; 11(5):054106. PubMed ID: 29034050
    [TBL] [Abstract][Full Text] [Related]  

  • 15. In vitro survival kinetics of microfluidic-sorted bovine spermatozoa.
    Ogata K; Nagata MPB; Nishizono H; Yamanouchi T; Matsuda H; Ogata Y; Takeda K; Hashiyada Y; Yamashita K
    Andrology; 2021 May; 9(3):977-988. PubMed ID: 33305455
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Effects of a microfluidic sperm sorter on sperm routine parameters and DNA integrity].
    Wang W; Liang GT; Peng YY; Liu DY; Zhou XM
    Zhonghua Nan Ke Xue; 2011 Apr; 17(4):301-4. PubMed ID: 21548204
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The use of complimentary assays to evaluate the enrichment of human sperm quality in asthenoteratozoospermic and teratozoospermic samples processed with Annexin-V magnetic activated cell sorting.
    Delbes G; Herrero MB; Troeung ET; Chan PT
    Andrology; 2013 Sep; 1(5):698-706. PubMed ID: 23843365
    [TBL] [Abstract][Full Text] [Related]  

  • 18. High-DNA integrity sperm selection using rheotaxis and boundary following behavior in a microfluidic chip.
    Zeaei S; Zabetian Targhi M; Halvaei I; Nosrati R
    Lab Chip; 2023 May; 23(9):2241-2248. PubMed ID: 37010363
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Towards an affinity-free, centrifugal microfluidic system for rapid, automated forensic differential extraction.
    Woolf MS; Cunha LL; Hadley KC; Moffett RP; Landers JP
    Anal Chim Acta; 2023 Apr; 1249():340826. PubMed ID: 36868762
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Leukocytospermia and sperm preparation--a flow cytometric study.
    Ricci G; Perticarari S; Boscolo R; Simeone R; Martinelli M; Fischer-Tamaro L; Guaschino S; Presani G
    Reprod Biol Endocrinol; 2009 Nov; 7():128. PubMed ID: 19925640
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.