These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

143 related articles for article (PubMed ID: 35280001)

  • 1. [Design of non-metallic crown for primary molars and analyzation of stress distribution: a finite element study].
    Tang ZW; Shi WH; Xia B; Yang JY; Zhao YJ; Wang Y
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2022 Mar; 57(3):242-250. PubMed ID: 35280001
    [No Abstract]   [Full Text] [Related]  

  • 2. Three-dimensional finite element analysis of molars with thin-walled prosthetic crowns made of various materials.
    Dejak B; Młotkowski A; Langot C
    Dent Mater; 2012 Apr; 28(4):433-41. PubMed ID: 22209573
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of Stresses Generated within the Supporting Structures of Mandibular Second Molars Restored with Different Crown Materials: 3-D Finite Element Analysis (FEA).
    Abuelenain DA; Ajaj R; El-Bab EI; Hammouda MM
    J Prosthodont; 2015 Aug; 24(6):484-93. PubMed ID: 25521774
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The effect of preparation design on the marginal stress of resin-bonded metal-free crowns: a finite element study.
    Shinya A; Lassila LV; Vallittu PK
    Int J Prosthodont; 2008; 21(5):445-7. PubMed ID: 18950069
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation of stress distribution of different marginal designs on PEEK and PEKK substructure materials, cortical and cancellous Bone:A finite element analysis.
    Karakaya K; Mutluay Ünal S
    Comput Biol Med; 2024 Aug; 178():108708. PubMed ID: 38861895
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effect of elasticity on stress distribution in CAD/CAM dental crowns: Glass ceramic vs. polymer-matrix composite.
    Duan Y; Griggs JA
    J Dent; 2015 Jun; 43(6):742-9. PubMed ID: 25625675
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effect of the crown design and interface lute parameters on the stress-state of a machined crown-tooth system: a finite element analysis.
    Shahrbaf S; vanNoort R; Mirzakouchaki B; Ghassemieh E; Martin N
    Dent Mater; 2013 Aug; 29(8):e123-31. PubMed ID: 23706694
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Three-dimensional finite element stress analysis of different designs of shape in all-ceramic crowns].
    Cheng B; Zhao Y; Wang H; Zhang J
    Sichuan Da Xue Xue Bao Yi Xue Ban; 2003 Apr; 34(2):265-6. PubMed ID: 12947708
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The influence of design parameters on the FEA-determined stress distribution in CAD-CAM produced all-ceramic dental crowns.
    De Jager N; Pallav P; Feilzer AJ
    Dent Mater; 2005 Mar; 21(3):242-51. PubMed ID: 15705431
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Three-dimensional finite element analysis of all-ceramic crowns of the posterior teeth].
    Zhang B; Zhao Y; Wang H
    Hua Xi Yi Ke Da Xue Xue Bao; 2000 Jun; 31(2):147-8, 164. PubMed ID: 12515118
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effect of finish line design on stress distribution in bilayer and monolithic zirconia crowns: a three-dimensional finite element analysis study.
    Miura S; Kasahara S; Yamauchi S; Egusa H
    Eur J Oral Sci; 2018 Apr; 126(2):159-165. PubMed ID: 29377334
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Finite element analysis of stress distribution in ceramic crowns fabricated with different tooth preparation designs.
    Oyar P; Ulusoy M; Eskitaşçıoğlu G
    J Prosthet Dent; 2014 Oct; 112(4):871-7. PubMed ID: 24750896
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Three-dimensional finite element analysis of different endodontic access methods and full crown restoration in the maxillary central incisor].
    Liu ZY; Zhao L; Yang LY; Gao X
    Hua Xi Kou Qiang Yi Xue Za Zhi; 2019 Dec; 37(6):642-647. PubMed ID: 31875444
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of stress distribution between zirconia/alloy endocrown and CAD/CAM multi-piece zirconia post-crown: three-dimensional finite element analysis.
    Yang J; Han F; Chen C; Xie H
    Clin Oral Investig; 2022 Jul; 26(7):5007-5017. PubMed ID: 35352185
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Evaluation of fracture strength of two kinds of zirconia all-ceramic crowns with different edge compensation angles].
    Yang X; Li R; Ye HQ; Chen H; Wang Y; Zhou YS; Sun YC
    Beijing Da Xue Xue Bao Yi Xue Ban; 2021 Mar; 53(2):402-405. PubMed ID: 33879918
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Is zirconium or stainless steel the most suitable crown material for less dentin stress in endodontically treated teeth?
    Guduk OF; Sivrikaya EC; Yilmaz N; Baygin O; Tuzuner T
    Technol Health Care; 2022; 30(5):1199-1207. PubMed ID: 35570506
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Three-dimensional finite element analysis on half of the structure defect with post core and all-ceramic crown restoration of mandibular first molar].
    Liu T; Geng H; Rong Q; Liu J
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2015 Sep; 50(9):561-4. PubMed ID: 26759300
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Three-dimensional finite element analysis of implant restoration in aesthetic zone of resin-ceramic composite single crown].
    Hong YR; Li Y; Luo WY; Xiao LJ; Gao YB
    Shanghai Kou Qiang Yi Xue; 2020 Jun; 29(3):262-266. PubMed ID: 33043342
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Influence of different base materials and thicknesses on the fracture resistance of endocrown: A three-dimensional finite element analysis.
    Cheng X; Zhang XY; Qian WH
    BMC Oral Health; 2022 Aug; 22(1):363. PubMed ID: 36008852
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Selection of optimal occlusal thickness and shoulder thickness in mandibular first molar all-ceramic crown: a three-dimensional finite element analysis].
    Wang WG; Zhang SF; Chen JJ; Li Y
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2011 Apr; 46(4):205-9. PubMed ID: 21612707
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.