These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

185 related articles for article (PubMed ID: 35280488)

  • 1. Augmented reality 3D navigation system for percutaneous CT-guided pulmonary ground-glass opacity biopsies: a comparison with the standard CT-guided technique.
    Faiella E; Messina L; Castiello G; Bernetti C; Pacella G; Altomare C; Andresciani F; Sarli M; Longo F; Crucitti P; Beomonte Zobel B; Grasso RF
    J Thorac Dis; 2022 Feb; 14(2):247-256. PubMed ID: 35280488
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Percutaneous low-dose CT-guided lung biopsy with an augmented reality navigation system: validation of the technique on 496 suspected lesions.
    Faiella E; Frauenfelder G; Santucci D; Luppi G; Schena E; Beomonte Zobel B; Grasso RF
    Clin Imaging; 2018; 49():101-105. PubMed ID: 29207301
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Lung Thermal Ablation: Comparison between an Augmented Reality Computed Tomography (CT) 3D Navigation System (SIRIO) and Standard CT-Guided Technique.
    Grasso RF; Andresciani F; Altomare C; Pacella G; Castiello G; Carassiti M; Quattrocchi CC; Faiella E; Beomonte Zobel B
    Biology (Basel); 2021 Jul; 10(7):. PubMed ID: 34356501
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Bone biopsies guided by augmented reality: a pilot study.
    Albano D; Messina C; Gitto S; Chianca V; Sconfienza LM
    Eur Radiol Exp; 2023 Jul; 7(1):40. PubMed ID: 37468652
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Percutaneous computed tomography-guided lung biopsies: preliminary results using an augmented reality navigation system.
    Grasso RF; Luppi G; Cazzato RL; Faiella E; D'Agostino F; Beomonte Zobel D; De Lena M
    Tumori; 2012 Nov; 98(6):775-82. PubMed ID: 23389366
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Impact of an Augmented Reality Navigation System (SIRIO) on Bone Percutaneous Procedures: A Comparative Analysis with Standard CT-Guided Technique.
    Faiella E; Castiello G; Bernetti C; Pacella G; Altomare C; Andresciani F; Beomonte Zobel B; Grasso RF
    Curr Oncol; 2021 May; 28(3):1751-1760. PubMed ID: 34066651
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Small (≤ 20 mm) ground-glass opacity pulmonary lesions: which factors influence the diagnostic accuracy of CT-guided percutaneous core needle biopsy?
    Li Y; Yang CF; Peng J; Li B; Zhang C; Yu JH
    BMC Pulm Med; 2022 Jul; 22(1):265. PubMed ID: 35799223
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Diagnostic accuracy of CT fluoroscopy-guided needle aspiration biopsy of ground-glass opacity pulmonary lesions.
    Hur J; Lee HJ; Nam JE; Kim YJ; Kim TH; Choe KO; Choi BW
    AJR Am J Roentgenol; 2009 Mar; 192(3):629-34. PubMed ID: 19234257
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Diagnostic performance of percutaneous lung biopsy using automated biopsy needles under CT-fluoroscopic guidance for ground-glass opacity lesions.
    Yamagami T; Yoshimatsu R; Miura H; Yamada K; Takahata A; Matsumoto T; Hasebe T
    Br J Radiol; 2013 Feb; 86(1022):20120447. PubMed ID: 23385998
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Percutaneous computed tomography-guided coaxial core biopsy for small pulmonary lesions with ground-glass attenuation.
    Lu CH; Hsiao CH; Chang YC; Lee JM; Shih JY; Wu LA; Yu CJ; Liu HM; Shih TT; Yang PC
    J Thorac Oncol; 2012 Jan; 7(1):143-50. PubMed ID: 22124475
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Percutaneous lung biopsy: comparison between an augmented reality CT navigation system and standard CT-guided technique.
    Grasso RF; Faiella E; Luppi G; Schena E; Giurazza F; Del Vescovo R; D'Agostino F; Cazzato RL; Beomonte Zobel B
    Int J Comput Assist Radiol Surg; 2013 Sep; 8(5):837-48. PubMed ID: 23377707
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of Smartphone Augmented Reality, Smartglasses Augmented Reality, and 3D CBCT-guided Fluoroscopy Navigation for Percutaneous Needle Insertion: A Phantom Study.
    Long DJ; Li M; De Ruiter QMB; Hecht R; Li X; Varble N; Blain M; Kassin MT; Sharma KV; Sarin S; Krishnasamy VP; Pritchard WF; Karanian JW; Wood BJ; Xu S
    Cardiovasc Intervent Radiol; 2021 May; 44(5):774-781. PubMed ID: 33409547
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Efficacy and safety of ultrasound (US) guided percutaneous needle biopsy for peripheral lung or pleural lesion: comparison with computed tomography (CT) guided needle biopsy.
    Yamamoto N; Watanabe T; Yamada K; Nakai T; Suzumura T; Sakagami K; Yoshimoto N; Sato K; Tanaka H; Mitsuoka S; Asai K; Kimura T; Kanazawa H; Hirata K; Kawaguchi T
    J Thorac Dis; 2019 Mar; 11(3):936-943. PubMed ID: 31019783
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Diagnostic performance of percutaneous core needle lung biopsy under multi-CT fluoroscopic guidance for ground-glass opacity pulmonary lesions.
    Yamauchi Y; Izumi Y; Nakatsuka S; Inoue M; Hayashi Y; Mukai M; Nomori H
    Eur J Radiol; 2011 Aug; 79(2):e85-9. PubMed ID: 21515009
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Diagnostic accuracy of CT-guided core biopsy of ground-glass opacity pulmonary lesions.
    Kim TJ; Lee JH; Lee CT; Jheon SH; Sung SW; Chung JH; Lee KW
    AJR Am J Roentgenol; 2008 Jan; 190(1):234-9. PubMed ID: 18094317
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Percutaneous lung biopsies: performance of an optical CT-based navigation system with a low-dose protocol.
    Grasso RF; Cazzato RL; Luppi G; D'Agostino F; Schena E; Del Vescovo R; Giurazza F; Faiella E; Beomonte Zobel B
    Eur Radiol; 2013 Nov; 23(11):3071-6. PubMed ID: 23783784
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Percutaneous Computed Tomography-Guided Lung Biopsies using a Virtual Navigation Guidance: Our Experience.
    Iannelli G; Caivano R; Villonio A; Semeraro V; Lucarelli NM; Ganimede MP; Gisone V; Dinardo G; Bruno S; Macarini L; Guglielmi G; Cammarota A
    Cancer Invest; 2018; 36(6):349-355. PubMed ID: 30095281
    [TBL] [Abstract][Full Text] [Related]  

  • 18. C-Arm Cone-Beam CT Virtual Navigation versus Conventional CT Guidance in the Transthoracic Lung Biopsy: A Case-Control Study.
    Yang L; Wang Y; Li L; Liu D; Wu X; Zhang W; Pan F; Liang H; Zheng C
    Diagnostics (Basel); 2022 Jan; 12(1):. PubMed ID: 35054282
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The application value of computed tomography in combination with intraoperative noninvasive percutaneous ultrasonic localisation of subpleural pulmonary nodules/ground-glass opacity in uniportal video-assisted thoracoscopy.
    Zhang Q; Wang Z; Jiang Y; Li F; Zhang Z; Cai H
    Wideochir Inne Tech Maloinwazyjne; 2021 Jun; 16(2):382-389. PubMed ID: 34136035
    [TBL] [Abstract][Full Text] [Related]  

  • 20. C-Arm Cone-Beam CT Virtual Navigation-Guided Percutaneous Mediastinal Mass Biopsy: Diagnostic Accuracy and Complications.
    Kim H; Park CM; Lee SM; Goo JM
    Eur Radiol; 2015 Dec; 25(12):3508-17. PubMed ID: 25916390
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.