259 related articles for article (PubMed ID: 35297696)
1. Comparison of CT-Guided Core Needle Biopsy in Pulmonary Ground-Glass and Solid Nodules Based on Propensity Score Matching Analysis.
An W; Zhang H; Wang B; Zhong F; Wang S; Liao M
Technol Cancer Res Treat; 2022; 21():15330338221085357. PubMed ID: 35297696
[No Abstract] [Full Text] [Related]
2. Assessment of diagnostic accuracy and complication rates of CT-guided percutaneous core-needle biopsy for lung lesion: difference between solid and sub-solid nodules based on propensity score matching analysis.
Lee SB; Kim MJ; Lee IJ
Clin Radiol; 2023 Sep; 78(9):e620-e626. PubMed ID: 37407369
[TBL] [Abstract][Full Text] [Related]
3. CT-guided percutaneous core needle biopsy for small (≤20 mm) pulmonary lesions.
Li Y; Du Y; Yang HF; Yu JH; Xu XX
Clin Radiol; 2013 Jan; 68(1):e43-8. PubMed ID: 23177650
[TBL] [Abstract][Full Text] [Related]
4. CT-guided percutaneous core needle biopsy of pulmonary nodules smaller than 2 cm: technical aspects and factors influencing accuracy.
Andrade JR; Rocha RD; Falsarella PM; Rahal Junior A; Santos RSD; Franceschini JP; Fernando HC; Garcia RG
J Bras Pneumol; 2018; 44(4):307-314. PubMed ID: 30328929
[TBL] [Abstract][Full Text] [Related]
5. Diagnostic accuracy and complications of CT-guided core needle lung biopsy of solid and part-solid lesions.
Yun S; Kang H; Park S; Kim BS; Park JG; Jung MJ
Br J Radiol; 2018 Jul; 91(1088):20170946. PubMed ID: 29770737
[TBL] [Abstract][Full Text] [Related]
6. Accuracy and complications of CT-guided pulmonary core biopsy in small nodules: a single-center experience.
Huang MD; Weng HH; Hsu SL; Hsu LS; Lin WM; Chen CW; Tsai YH
Cancer Imaging; 2019 Jul; 19(1):51. PubMed ID: 31337425
[TBL] [Abstract][Full Text] [Related]
7. Diagnostic performance and safety of percutaneous fine-needle aspiration immediately before microwave ablation for pulmonary ground-glass nodules.
Peng JZ; Bie ZX; Li YM; Li B; Guo RQ; Wang CE; Xu S; Li XG
Quant Imaging Med Surg; 2023 Jun; 13(6):3852-3861. PubMed ID: 37284082
[TBL] [Abstract][Full Text] [Related]
8. Efficacy and Safety Analysis of Multislice Spiral CT-Guided Transthoracic Lung Biopsy in the Diagnosis of Pulmonary Nodules of Different Sizes.
Liu H; Yao X; Xu B; Zhang W; Lei Y; Chen X
Comput Math Methods Med; 2022; 2022():8192832. PubMed ID: 36060660
[TBL] [Abstract][Full Text] [Related]
9. Transthoracic Computed Tomography-Guided Lung Nodule Biopsy: Comparison of Core Needle and Fine Needle Aspiration Techniques.
Sangha BS; Hague CJ; Jessup J; O'Connor R; Mayo JR
Can Assoc Radiol J; 2016 Aug; 67(3):284-9. PubMed ID: 27005931
[TBL] [Abstract][Full Text] [Related]
10. Comparison between computed tomography-guided core and fine needle lung biopsy: A meta-analysis.
Li Y; Yang F; Huang YY; Cao W
Medicine (Baltimore); 2022 Mar; 101(9):e29016. PubMed ID: 35244081
[TBL] [Abstract][Full Text] [Related]
11. Complications and diagnostic accuracy of CT-guided 18G tru-cut versus end-cut percutaneous core needle biopsy of solitary solid lung nodules.
Echevarria-Uraga JJ; Del Cura-Allende G; Armendariz-Tellitu K; Berastegi-Santamaria C; Egurrola-Izquierdo M; Anton-Ladislao A
Diagn Interv Radiol; 2022 Jan; 28(1):58-64. PubMed ID: 34914606
[TBL] [Abstract][Full Text] [Related]
12. Application of 3-Dimensionally Printed Coplanar Template Improves Diagnostic Yield of CT-Guided Percutaneous Core Needle Biopsy for Pulmonary Nodules.
Wang H; Ren T; Chen P; Luo G; Wei N; Tang Y; Wang M
Technol Cancer Res Treat; 2022; 21():15330338221089940. PubMed ID: 35410551
[No Abstract] [Full Text] [Related]
13. Computed tomography fluoroscopy-guided cutting needle biopsy of pulmonary nodules ≤8 mm: A retrospective study including 117 nodules.
Zhao Y; Matsui Y; Hiraki T; Iguchi T; Tomita K; Uka M; Gobara H; Toyooka S; Kanazawa S
Eur J Radiol; 2020 Apr; 125():108903. PubMed ID: 32088660
[TBL] [Abstract][Full Text] [Related]
14. Computed tomography-guided cutting needle biopsy for lung nodules: A comparative study between low-dose and standard dose protocols.
Zhang HM; Huo XB; Wang HL; Zhang X; Fu YF
Medicine (Baltimore); 2021 Jan; 100(3):e24001. PubMed ID: 33545994
[TBL] [Abstract][Full Text] [Related]
15. Propensity-score-matching analysis to compare efficacy and safety between 16-gauge and 18-gauge needle in ultrasound-guided biopsy for peripheral pulmonary lesions.
Huang W; Ye J; Qiu Y; Peng W; Lan N; Cui W; Huang T; Ou Y; Li Y
BMC Cancer; 2021 Apr; 21(1):390. PubMed ID: 33836683
[TBL] [Abstract][Full Text] [Related]
16. Small (≤ 20 mm) ground-glass opacity pulmonary lesions: which factors influence the diagnostic accuracy of CT-guided percutaneous core needle biopsy?
Li Y; Yang CF; Peng J; Li B; Zhang C; Yu JH
BMC Pulm Med; 2022 Jul; 22(1):265. PubMed ID: 35799223
[TBL] [Abstract][Full Text] [Related]
17. Complications and Yield of Computed Tomography-Guided Transthoracic Core Needle Biopsy of Lung Nodules at a High-Volume Academic Center in an Endemic Coccidioidomycosis Area.
Sachdeva M; Ronaghi R; Mills PK; Peterson MW
Lung; 2016 Jun; 194(3):379-85. PubMed ID: 26980483
[TBL] [Abstract][Full Text] [Related]
18. Pneumothorax Complicating Coaxial and Non-coaxial CT-Guided Lung Biopsy: Comparative Analysis of Determining Risk Factors and Management of Pneumothorax in a Retrospective Review of 650 Patients.
Nour-Eldin NE; Alsubhi M; Emam A; Lehnert T; Beeres M; Jacobi V; Gruber-Rouh T; Scholtz JE; Vogl TJ; Naguib NN
Cardiovasc Intervent Radiol; 2016 Feb; 39(2):261-70. PubMed ID: 26148648
[TBL] [Abstract][Full Text] [Related]
19. Risk factors for pneumothorax and pulmonary hemorrhage following computed tomography-guided transthoracic core-needle biopsy of subpleural lung lesions.
Chiu JH; Chang YY; Weng CY; Lee YC; Yeh YC; Chen CK
J Chin Med Assoc; 2022 Apr; 85(4):500-506. PubMed ID: 35383704
[TBL] [Abstract][Full Text] [Related]
20. Complication rates of CT-guided transthoracic lung biopsy: meta-analysis.
Heerink WJ; de Bock GH; de Jonge GJ; Groen HJ; Vliegenthart R; Oudkerk M
Eur Radiol; 2017 Jan; 27(1):138-148. PubMed ID: 27108299
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]