These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

125 related articles for article (PubMed ID: 35299130)

  • 1. Accuracy of ASTA MicroIDSys, a new matrix-assisted laser desorption/ionization time-of-flight mass spectrometry system, for the identification of Korean reference and clinical bacterial and yeast strains.
    Ko YJ; Lee OJ; Lee SB; Kim CM; Lee J; Kook JK; Park SN; Shin JH; Kim SH; Won EJ; Park G; Kang SH; Jang SJ
    Diagn Microbiol Infect Dis; 2022 May; 103(1):115658. PubMed ID: 35299130
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Performance assessment of ASTA MicroIDSys, a new matrix assisted laser desorption ionization-time of flight mass spectrometry system, for identification of viridans group streptococci.
    Lee OJ; Ko YJ; Lee SB; Kim CM; Jang SJ; Kook JK; Lim YK; Shin JH; Shin MG; Kee SJ; Jeong SH; Kang SH; Park G
    Microbiol Immunol; 2021 Dec; 65(12):566-574. PubMed ID: 34516008
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparative Evaluation of Bruker Biotyper and ASTA MicroIDSys for Species Identification in a Clinical Microbiology Laboratory.
    Chung Y; Han M; Kim JS
    Diagnostics (Basel); 2021 Sep; 11(9):. PubMed ID: 34574024
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of a New Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry Platform, ASTA MicroIDSys, With Bruker Biotyper for Species Identification.
    Lee Y; Sung JY; Kim H; Yong D; Lee K
    Ann Lab Med; 2017 Nov; 37(6):531-535. PubMed ID: 28840993
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Performance evaluation of a new matrix-assisted laser desorption/ionization time-of-flight mass spectrometry, ASTA MicroIDSys system, in bacterial identification against clinical isolates of anaerobic bacteria.
    Kim D; Ji S; Kim JR; Kim M; Byun JH; Yum JH; Yong D; Lee K
    Anaerobe; 2020 Feb; 61():102131. PubMed ID: 31778809
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of the ASTA MicroIDSys and VITEK MS matrix-assisted laser desorption/ionization time-of-flight mass spectrometry systems for identification of clinical bacteria and yeasts.
    Jung J; Kim SY; Park YJ; Lee J; Suk HS; Ha SI; Shin JS; Park KG; Kim Y
    J Infect Chemother; 2020 Dec; 26(12):1328-1333. PubMed ID: 32855038
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Performance Evaluation of Bruker Biotyper, ASTA MicroIDSys, and VITEK-MS and Three Extraction Methods for Filamentous Fungal Identification in Clinical Laboratories.
    Choi Y; Kim D; Choe KW; Lee H; Kim JS; Ahn JY; Lee MK
    J Clin Microbiol; 2022 Nov; 60(11):e0081222. PubMed ID: 36286489
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Multilaboratory Evaluation of the MALDI-TOF Mass Spectrometry System, MicroIDSys Elite, for the Identification of Medically Important Filamentous Fungi.
    Lee H; Oh J; Sung GH; Koo J; Lee MH; Lee HJ; Cho SI; Choi JS; Park YJ; Shin JH; Lee HK; Kim SY; Lee CH; Kim YR; Sohn YH; Kim WJ; Ryu SW; Lee NY; Huh HJ; Kim J
    Mycopathologia; 2021 Mar; 186(1):15-26. PubMed ID: 33180204
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluation of a new matrix-assisted laser desorption/ionization time-of-flight mass spectrometry system for the identification of yeast isolation.
    Lee H; Park JH; Oh J; Cho S; Koo J; Park IC; Kim J; Park S; Choi JS; Shin SY; Sung GH; Kim J
    J Clin Lab Anal; 2019 Feb; 33(2):e22685. PubMed ID: 30298531
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Application of the Whole Genome-Based Bacterial Identification System, TrueBac ID, Using Clinical Isolates That Were Not Identified With Three Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry (MALDI-TOF MS) Systems.
    Ha SM; Kim CK; Roh J; Byun JH; Yang SJ; Choi SB; Chun J; Yong D
    Ann Lab Med; 2019 Nov; 39(6):530-536. PubMed ID: 31240880
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of the ASTA MicroIDSys matrix-assisted laser desorption ionization time-of-flight mass spectrometry system for identification of mycobacteria directly from positive MGIT liquid cultures.
    Yoo IY; Shim HJ; Yun SA; Kang OK; Chung YN; Kim TY; Lee H; Kim J; Park YJ; Huh HJ; Lee NY
    Int J Infect Dis; 2021 Jan; 102():172-177. PubMed ID: 33039611
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Substantial Improvement in Nontuberculous Mycobacterial Identification Using ASTA MicroIDSys Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry with an Upgraded Database.
    Song J; Yoon S; In Y; Kim D; Lee H; Yong D; Lee K
    Ann Lab Med; 2022 May; 42(3):358-362. PubMed ID: 34907106
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of the Bruker Biotyper and VITEK MS Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry Systems Using a Formic Acid Extraction Method to Identify Common and Uncommon Yeast Isolates.
    Lee HS; Shin JH; Choi MJ; Won EJ; Kee SJ; Kim SH; Shin MG; Suh SP
    Ann Lab Med; 2017 May; 37(3):223-230. PubMed ID: 28224768
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Performance Comparison Between Fourier-Transform Infrared Spectroscopy-based IR Biotyper and Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry for Strain Diversity.
    Jun SY; Kim YA; Lee SJ; Jung WW; Kim HS; Kim SS; Kim H; Yong D; Lee K
    Ann Lab Med; 2023 Mar; 43(2):174-179. PubMed ID: 36281511
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Ongoing revolution in bacteriology: routine identification of bacteria by matrix-assisted laser desorption ionization time-of-flight mass spectrometry.
    Seng P; Drancourt M; Gouriet F; La Scola B; Fournier PE; Rolain JM; Raoult D
    Clin Infect Dis; 2009 Aug; 49(4):543-51. PubMed ID: 19583519
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparative evaluation of the Bruker Biotyper and Vitek MS matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) systems for non-albicans Candida and uncommon yeast isolates.
    Teke L; Barış A; Bayraktar B
    J Microbiol Methods; 2021 Jun; 185():106232. PubMed ID: 33961963
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A Side by Side Comparison of Bruker Biotyper and VITEK MS: Utility of MALDI-TOF MS Technology for Microorganism Identification in a Public Health Reference Laboratory.
    Lévesque S; Dufresne PJ; Soualhine H; Domingo MC; Bekal S; Lefebvre B; Tremblay C
    PLoS One; 2015; 10(12):e0144878. PubMed ID: 26658918
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Matrix-assisted laser desorption ionization time-of-flight mass spectrometry and database for identification of Legionella species.
    He Y; Chang TC; Li H; Shi G; Tang YW
    Can J Microbiol; 2011 Jul; 57(7):533-8. PubMed ID: 21767077
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Applicability of an in-House Saponin-Based Extraction Method in Bruker Biotyper Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry System for Identification of Bacterial and Fungal Species in Positively Flagged Blood Cultures.
    Chien JY; Lee TF; Du SH; Teng SH; Liao CH; Sheng WH; Teng LJ; Hsueh PR
    Front Microbiol; 2016; 7():1432. PubMed ID: 27695442
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Direct bacterial identification in positive blood cultures by use of two commercial matrix-assisted laser desorption ionization-time of flight mass spectrometry systems.
    Chen JH; Ho PL; Kwan GS; She KK; Siu GK; Cheng VC; Yuen KY; Yam WC
    J Clin Microbiol; 2013 Jun; 51(6):1733-9. PubMed ID: 23515548
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.