These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

107 related articles for article (PubMed ID: 35302410)

  • 1. Stop posterior wall puncture of the arteriovenous graft (AVG). New findings of cannulation techniques from a prospective observational study with an AVG model and plastic cannula for dialysis.
    Kimura G; Matsuyama T; Mizuno Y
    J Vasc Access; 2023 Nov; 24(6):1299-1304. PubMed ID: 35302410
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Computational Modelling Based Recommendation on Optimal Dialysis Needle Positioning and Dialysis Flow in Patients With Arteriovenous Grafts.
    Quicken S; Huberts W; Tordoir J; van Loon M; Delhaas T; Mees B
    Eur J Vasc Endovasc Surg; 2020 Feb; 59(2):288-294. PubMed ID: 31883684
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Prospective multicenter study with a 1-year analysis of a new vascular graft used for early cannulation in patients undergoing hemodialysis.
    Glickman MH; Burgess J; Cull D; Roy-Chaudhury P; Schanzer H
    J Vasc Surg; 2015 Aug; 62(2):434-41. PubMed ID: 25953016
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Considerations in Access Cannulation: Traditional and Evolving Approaches.
    Kumbar L; Ramani K; Brouwer-Maier D
    Adv Chronic Kidney Dis; 2020 May; 27(3):199-207. PubMed ID: 32891303
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Increased blood loss from access cannulation site during hemodialysis is associated with anemia and arteriovenous graft use.
    Lin CL; Chen HY; Huang SC; Hsu SP; Pai MF; Peng YS; Chiu YL
    Ther Apher Dial; 2014 Feb; 18(1):51-6. PubMed ID: 24499084
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Cannulation practice patterns in haemodialysis vascular access: predictors for unsuccessful cannulation.
    van Loon MM; Kessels AG; van der Sande FM; Tordoir JH
    J Ren Care; 2009 Jun; 35(2):82-9. PubMed ID: 19432853
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Plastic cannula use in hemodialysis access.
    Smith V; Schoch M
    J Vasc Access; 2016 Sep; 17(5):405-10. PubMed ID: 26980628
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Surgical and endovascular assisted maturation procedures improve cannulation after arteriovenous fistula creation, but not after arteriovenous graft placement.
    Hafeez MS; Chaer RA; Eslami MH; Abdul-Malak OM; Yuo TH
    J Vasc Access; 2024 Sep; 25(5):1649-1658. PubMed ID: 37421151
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Hydrogel-coated needles prevent puncture site bleeding in arteriovenous fistula and arteriovenous grafts in rats.
    Xu Y; Wang Z; Wei S; Sun P; Bai H; Li J
    Biomed Pharmacother; 2021 Nov; 143():112113. PubMed ID: 34474341
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Bacteriology of the Buttonhole Cannulation Tract in Hemodialysis Patients: A Prospective Cohort Study.
    Christensen LD; Skadborg MB; Mortensen AH; Mortensen C; Møller JK; Lemming L; Høgsberg I; Petersen SE; Buus NH
    Am J Kidney Dis; 2018 Aug; 72(2):234-242. PubMed ID: 29605379
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Efficacy and Safety of Plastic Cannulae Compared with Metal Needles in the Initial Use of an Arteriovenous Fistulae in Incident Hemodialysis Patients: A Randomized Controlled Study.
    Choi YS; Lee HS; Joo N; Park P; Cho SN; Youn IJ; Song YR; Kim SG; Kim JK
    Am J Nephrol; 2021; 52(6):479-486. PubMed ID: 34111865
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Plastic cannulae versus metal needle cannulation in haemodialysis: Results of an international survey from the nurse perspective.
    de Barbieri I; Sisti D; Strini V; Noble H; Parisotto MT; Amatori S; Rocchi MB
    J Vasc Access; 2023 Sep; 24(5):1025-1031. PubMed ID: 34965758
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Handheld ultrasound-guided cannulation of difficult hemodialysis arteriovenous access: A randomized controlled trial.
    Chen S; Liu JS; Chai CC; Si C; Tan SH; Ravindran HR; Martinez MTP; Gao Y; Yeap YR; Liu AYL
    Hemodial Int; 2023 Jan; 27(1):21-27. PubMed ID: 36281908
    [TBL] [Abstract][Full Text] [Related]  

  • 14. An immediate access dialysis graft designed to prevent needle-related complications: Results from the initial pre-clinical studies.
    Gage SM; Lawson M; Nichols C; Sycks D; Manson RJ; Knight JA
    J Vasc Access; 2020 May; 21(3):328-335. PubMed ID: 31526086
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Axillo-iliac arteriovenous hemodialysis graft creation with an early cannulation device.
    Hinojosa CA; Anaya-Ayala JE; Lopez-Mendez A; Gomez-Arcive Z; Laparra-Escareno H; Cuen-Ojeda C; Lizola R; Torres-Machorro A
    J Artif Organs; 2017 Mar; 20(1):57-61. PubMed ID: 27709306
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Buttonhole technique better than area puncture technique on hemostasis and pain associated with needle cannulation.
    Sukthinthai N; Sittipraneet A; Tummanittayangkoon B; Vasuvattakul S; Chanchairujira T
    J Med Assoc Thai; 2012 Feb; 95 Suppl 2():S208-12. PubMed ID: 22574551
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The Venous Window Needle Guide, a hemodialysis cannulation device for salvage of uncannulatable arteriovenous fistulas.
    Jennings WC; Galt SW; Shenoy S; Wang S; Ladenheim ED; Glickman MH; Kathuria P; Browne BJ
    J Vasc Surg; 2014 Oct; 60(4):1024-32. PubMed ID: 24833247
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Vascular access cannulation in hemodialysis patients - a survey of current practice and its relation to dialysis dose.
    Gauly A; Parisotto MT; Skinder A; Schoder V; Furlan A; Schuh E; Marcelli D
    J Vasc Access; 2011; 12(4):358-64. PubMed ID: 21688239
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Tradeoffs in Vascular Access Selection in Elderly Patients Initiating Hemodialysis With a Catheter.
    Lee T; Qian J; Thamer M; Allon M
    Am J Kidney Dis; 2018 Oct; 72(4):509-518. PubMed ID: 29784614
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Impact of simulation-based training in addition to theoretical training versus theoretical training of nurses alone in the occurrence of adverse events related to arteriovenous fistula puncture in chronic hemodialysis patients: study for a cluster randomized controlled trial (SIMFAV2).
    Guillouet E; Tomadesso C; Flores BA; Henri P; Lanot A; Morello R; Guillouet S
    Trials; 2023 Aug; 24(1):500. PubMed ID: 37550740
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.