133 related articles for article (PubMed ID: 35305378)
1. Performance assessment of the new Xpert® HIV-1 viral load XC assay for quantification of HIV-1 viral loads.
Ehret R; Harb K; Breuer S; Obermeier M
J Clin Virol; 2022 Apr; 149():105127. PubMed ID: 35305378
[TBL] [Abstract][Full Text] [Related]
2. Multi-site clinical evaluation of the Xpert(®) HIV-1 viral load assay.
Jordan JA; Plantier JC; Templeton K; Wu AH
J Clin Virol; 2016 Jul; 80():27-32. PubMed ID: 27135387
[TBL] [Abstract][Full Text] [Related]
3. Performance Evaluation of the New HIV-1 Quantification Assay, Xpert HIV-1 Viral Load, on a Wide Panel of HIV-1 Variants.
Gueudin M; Baron A; Alessandri-Gradt E; Lemée V; Mourez T; Etienne M; Plantier JC
J Acquir Immune Defic Syndr; 2016 Aug; 72(5):521-6. PubMed ID: 27007866
[TBL] [Abstract][Full Text] [Related]
4. Evaluation of the RealTime HIV-1, Xpert HIV-1, and Aptima HIV-1 Quant Dx Assays in Comparison to the NucliSens EasyQ HIV-1 v2.0 Assay for Quantification of HIV-1 Viral Load.
Mor O; Gozlan Y; Wax M; Mileguir F; Rakovsky A; Noy B; Mendelson E; Levy I
J Clin Microbiol; 2015 Nov; 53(11):3458-65. PubMed ID: 26292298
[TBL] [Abstract][Full Text] [Related]
5. Diagnostic Accuracy of the Rapid Xpert HIV-1 Viral Load XC, Xpert HIV-1 Viral Load, & m-PIMA HIV-1/2 Viral Load in South African Clinics.
Dorward J; Naidoo J; Moodley P; Sookrajh Y; Samsunder N; Sayed F; Naicker N; Fanshawe T; Drain PK; Lessells RJ; Hayward G; Butler CC; Garrett N
J Acquir Immune Defic Syndr; 2022 Oct; 91(2):189-196. PubMed ID: 36094486
[TBL] [Abstract][Full Text] [Related]
6. Comparison between Roche and Xpert in HIV-1 RNA quantitation: A high concordance between the two techniques except for a CRF02_AG subtype variant with high viral load titters detected by Roche but undetected by Xpert.
Avidor B; Matus N; Girshengorn S; Achsanov S; Gielman S; Zeldis I; Schweitzer I; Adler A; Turner D
J Clin Virol; 2017 Aug; 93():15-19. PubMed ID: 28564629
[TBL] [Abstract][Full Text] [Related]
7. Point-of-Care Cepheid Xpert HIV-1 Viral Load Test in Rural African Communities Is Feasible and Reliable.
Moyo S; Mohammed T; Wirth KE; Prague M; Bennett K; Holme MP; Mupfumi L; Sebogodi P; Moraka NO; Boleo C; Maphorisa CN; Seraise B; Gaseitsiwe S; Musonda RM; van Widenfelt E; Powis KM; Gaolathe T; Tchetgen Tchetgen EJ; Makhema JM; Essex M; Lockman S; Novitsky V
J Clin Microbiol; 2016 Dec; 54(12):3050-3055. PubMed ID: 27733636
[TBL] [Abstract][Full Text] [Related]
8. Performance Comparison of Xpert HIV-1 Viral Load Assay and Roche Taqman and Abbott M2000 RT in Bamako, Mali.
Kone B; Goita D; Dolo O; Traore D; Sogoba D; Somboro A; Sanogo M; Somboro AM; Coulibaly N; Sanogo A; Diarra Z; Traore M; Maiga AI; Baya B; Sarro YDS; Diarra B; Kone A; Diallo D; Dabitao D; Holl JL; Belson M; Dao S; Murphy RL; Diakite M; Diallo S; Doumbia S; Maiga M
J AIDS Clin Res; 2020; 11(7):. PubMed ID: 34295571
[TBL] [Abstract][Full Text] [Related]
9. Multicenter Evaluation of Two Next-Generation HIV-1 Quantitation Assays, Aptima Quant Dx and Cobas 6800, in Comparison to the RealTi
Wiesmann F; Ehret R; Naeth G; Däumer M; Fuhrmann J; Kaiser R; Noah C; Obermeier M; Schalasta G; Tiemann C; Wolf E; Knechten H; Braun P
J Clin Microbiol; 2018 Oct; 56(10):. PubMed ID: 30068537
[TBL] [Abstract][Full Text] [Related]
10. Comparison of the Abbott Alinity m and m2000 assays for the quantification of HIV-1, HCV and HBV in clinical samples.
Mouna L; Pallier C; Proust S; Prégermain C; Roque-Afonso AM
J Clin Virol; 2020 May; 126():104331. PubMed ID: 32179444
[TBL] [Abstract][Full Text] [Related]
11. High correlation between the Roche COBAS® AmpliPrep/COBAS® TaqMan® HIV-1, v2.0 and the Abbott m2000 RealTime HIV-1 assays for quantification of viral load in HIV-1 B and non-B subtypes.
Karasi JC; Dziezuk F; Quennery L; Förster S; Reischl U; Colucci G; Schoener D; Seguin-Devaux C; Schmit JC
J Clin Virol; 2011 Nov; 52(3):181-6. PubMed ID: 21813320
[TBL] [Abstract][Full Text] [Related]
12. Evaluation of the performance of the Cepheid Xpert HIV-1 Viral Load Assay for quantitative and diagnostic uses.
Wesolowski L; Fowler W; Luo W; Sullivan V; Masciotra S; Smith T; Rossetti R; Delaney K; Oraka E; Chavez P; Ethridge S; Switzer WM; Owen SM
J Clin Virol; 2020 Jan; 122():104214. PubMed ID: 31835210
[TBL] [Abstract][Full Text] [Related]
13. Performance of the Xpert HIV-1 Viral Load Assay: a Systematic Review and Meta-analysis.
Nash M; Huddart S; Badar S; Baliga S; Saravu K; Pai M
J Clin Microbiol; 2018 Apr; 56(4):. PubMed ID: 29386266
[TBL] [Abstract][Full Text] [Related]
14. Comparative evaluation of the performance of the Abbott RealTime HIV-1 assay for measurement of HIV-1 plasma viral load on genetically diverse samples from Greece.
Katsoulidou A; Rokka C; Issaris C; Haida C; Tzannis K; Sypsa V; Detsika M; Paraskevis D; Hatzakis A
Virol J; 2011 Jan; 8():10. PubMed ID: 21219667
[TBL] [Abstract][Full Text] [Related]
15. Performance of Xpert HIV-1 viral load test in Senegal: a country of high circulation of CRF02_AG.
Sène PY; Diop-Ndiaye H; Ndoye AS; Kiernan B; Coulibaly K; Ndiaye O; Diallo S; Ndiaye AJS; Fall M; Ba AA; Camara M; Boye CSB; Ngom NF; Lejeune C; Ndour CT; Kane CT
Pan Afr Med J; 2022; 42():136. PubMed ID: 36060855
[TBL] [Abstract][Full Text] [Related]
16. HIV-1 viral load measurement in venous blood and fingerprick blood using Abbott RealTime HIV-1 DBS assay.
Tang N; Pahalawatta V; Frank A; Bagley Z; Viana R; Lampinen J; Leckie G; Huang S; Abravaya K; Wallis CL
J Clin Virol; 2017 Jul; 92():56-61. PubMed ID: 28531553
[TBL] [Abstract][Full Text] [Related]
17. Options to Expand HIV Viral Load Testing in South Africa: Evaluation of the GeneXpert® HIV-1 Viral Load Assay.
Gous N; Scott L; Berrie L; Stevens W
PLoS One; 2016; 11(12):e0168244. PubMed ID: 27992495
[TBL] [Abstract][Full Text] [Related]
18. Multicenter evaluation of Xpert HIV-1 viral load assay for HIV quantification in China.
Liu L; Deng R; Lan Y; Li L; Li M; Su B; Gnanashanmugam D; Tang YW; Wu H; Wang J; Cai X; Zhang T
J Med Virol; 2020 Dec; 92(12):3295-3300. PubMed ID: 32652607
[TBL] [Abstract][Full Text] [Related]
19. Evaluating the Dual-Target Aptima HIV-1 Quant Dx Assay: Comparison between Viral Loads Measured with
Sberna G; Sarti S; Cicalini S; Antinori A; Garbuglia AR; Amendola A
Microbiol Spectr; 2022 Oct; 10(5):e0136122. PubMed ID: 36066258
[TBL] [Abstract][Full Text] [Related]
20. Comparison of the performance of Aptima HIV-1 Quant Dx Assay with Abbott RealTime HIV Assay for viral load monitoring using plasma and Dried Blood Spots collected in Kenya.
Mwau M; Schaffer S; Kimani H; Kasiano P; Ogolla F; Ajema E; Adoyo S; Nyairo E; Saleri N; Nair SV
PLoS One; 2022; 17(8):e0269838. PubMed ID: 35994447
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]