132 related articles for article (PubMed ID: 35314535)
1. [Gantry QA Using Three-dimensional Diode Array Detector on O-ring Linear Accelerator].
Sakamoto T; Matsumoto K; Otsuka M; Nanbu H; Okumura M
Nihon Hoshasen Gijutsu Gakkai Zasshi; 2022; 78(3):263-269. PubMed ID: 35314535
[TBL] [Abstract][Full Text] [Related]
2. Filmless methods for quality assurance of Tomotherapy using ArcCHECK.
Yang B; Wong WK; Geng H; Lam WW; Ho YW; Kwok WM; Cheung KY; Yu SK
Med Phys; 2017 Jan; 44(1):7-16. PubMed ID: 28044341
[TBL] [Abstract][Full Text] [Related]
3. A novel method for routine quality assurance of volumetric-modulated arc therapy.
Wang Q; Dai J; Zhang K
Med Phys; 2013 Oct; 40(10):101712. PubMed ID: 24089902
[TBL] [Abstract][Full Text] [Related]
4. The measurement of linear accelerator isocenter motion using a three-micrometer device and an adjustable pointer.
Tsai JS; Curran BH; Sternick ES; Engler MJ
Int J Radiat Oncol Biol Phys; 1996 Jan; 34(1):189-95. PubMed ID: 12118550
[TBL] [Abstract][Full Text] [Related]
5. A novel and independent method for time-resolved gantry angle quality assurance for VMAT.
Fuangrod T; Greer PB; Zwan BJ; Barnes MP; Lehmann J
J Appl Clin Med Phys; 2017 Sep; 18(5):134-142. PubMed ID: 28703451
[TBL] [Abstract][Full Text] [Related]
6. Comprehensive validation of halcyon 2.0 plans and the implementation of patient specific QA with multiple detector platforms.
Laugeman E; Heermann A; Hilliard J; Watts M; Roberson M; Morris R; Goddu S; Sethi A; Zoberi I; Kim H; Mutic S; Hugo G; Cai B
J Appl Clin Med Phys; 2020 Jul; 21(7):39-48. PubMed ID: 32368862
[TBL] [Abstract][Full Text] [Related]
7. Technical note: Comprehensive evaluations of gantry and couch rotation isocentricities for implementing proton stereotactic radiosurgery.
Shen J; Robertson DG; Bues M; Shipulin K; Liu W; Stoker J; Ashman JB; Lara P; Keole SR; Wong W; Vora SA
Med Phys; 2023 Jun; 50(6):3359-3367. PubMed ID: 36959772
[TBL] [Abstract][Full Text] [Related]
8. A comprehensive geometric quality assurance framework for preclinical microirradiators.
Anvari A; Poirier Y; Sawant A
Med Phys; 2019 Apr; 46(4):1840-1851. PubMed ID: 30656713
[TBL] [Abstract][Full Text] [Related]
9. Quality assurance of non-coplanar, volumetric-modulated arc therapy employing a C-arm linear accelerator, featuring continuous patient couch rotation.
Hirashima H; Nakamura M; Miyabe Y; Mukumoto N; Ono T; Iramina H; Mizowaki T
Radiat Oncol; 2019 Apr; 14(1):62. PubMed ID: 30971273
[TBL] [Abstract][Full Text] [Related]
10. Evaluation of the sensitivity of two 3D diode array dosimetry systems to setup error for quality assurance (QA) of volumetric-modulated arc therapy (VMAT).
Li G; Bai S; Chen N; Henderson L; Wu K; Xiao J; Zhang Y; Jiang Q; Jiang X
J Appl Clin Med Phys; 2013 Sep; 14(5):13-24. PubMed ID: 24036856
[TBL] [Abstract][Full Text] [Related]
11. An EPID-based method to determine mechanical deformations in a linear accelerator.
Gourdeau D; Gingras L; Beaulieu F; Leclerc G; Archambault L
Med Phys; 2018 Nov; 45(11):5054-5065. PubMed ID: 30242848
[TBL] [Abstract][Full Text] [Related]
12. Patient-specific quality assurance on a Varian Halcyon linear accelerator using a PTW Octavius 4D device.
Aland T; Jarema T; Trapp JV; Kairn T
Phys Eng Sci Med; 2021 Jun; 44(2):565-572. PubMed ID: 33704691
[TBL] [Abstract][Full Text] [Related]
13. Measuring the wobble of radiation field centers during gantry rotation and collimator movement on a linear accelerator.
Du W; Gao S
Med Phys; 2011 Aug; 38(8):4575-8. PubMed ID: 21928629
[TBL] [Abstract][Full Text] [Related]
14. Measurement of mechanical accuracy of isocenter in conventional linear-accelerator-based radiosurgery.
Gibbs FA; Buechler D; Leavitt DD; Moeller JH
Int J Radiat Oncol Biol Phys; 1993 Jan; 25(1):117-22. PubMed ID: 8416867
[TBL] [Abstract][Full Text] [Related]
15. Independent validation of machine performance check for the Halcyon and TrueBeam linacs for daily quality assurance.
Li Y; Netherton T; Nitsch PL; Gao S; Klopp AH; Balter PA; Court LE
J Appl Clin Med Phys; 2018 Sep; 19(5):375-382. PubMed ID: 30016578
[TBL] [Abstract][Full Text] [Related]
16. Comparisons of volumetric modulated arc therapy (VMAT) quality assurance (QA) systems: sensitivity analysis to machine errors.
Liang B; Liu B; Zhou F; Yin FF; Wu Q
Radiat Oncol; 2016 Nov; 11(1):146. PubMed ID: 27821135
[TBL] [Abstract][Full Text] [Related]
17. A novel verification method using a plastic scintillator imagining system for assessment of gantry sag in radiotherapy.
Tsuneda M; Nishio T; Saito A; Tanaka S; Suzuki T; Kawahara D; Matsushita K; Nishio A; Ozawa S; Karasawa K; Nagata Y
Med Phys; 2018 Jun; 45(6):2411-2424. PubMed ID: 29663431
[TBL] [Abstract][Full Text] [Related]
18. Variation in Elekta iView electronic portal imager pixel scale factor with gantry angle, and impact on multi-leaf collimator quality assurance.
Goodall SK; Norvill C
J Appl Clin Med Phys; 2022 Jul; 23(7):e13661. PubMed ID: 35666629
[TBL] [Abstract][Full Text] [Related]
19. Halcyon clinical performance evaluation: A log file-based study in comparison with a C-arm Linac.
Wang R; Du Y; Yao K; Liu Z; Wang H; Yue H; Zhang Y; Wu H
Phys Med; 2020 Mar; 71():14-23. PubMed ID: 32086148
[TBL] [Abstract][Full Text] [Related]
20. Longitudinal assessment of quality assurance measurements in a 1.5T MR-linac: Part I-Linear accelerator.
Subashi E; Lim SB; Gonzalez X; Tyagi N
J Appl Clin Med Phys; 2021 Oct; 22(10):190-201. PubMed ID: 34505349
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]