These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

115 related articles for article (PubMed ID: 35318959)

  • 1. Assessment of three MR perfusion software packages in predicting final infarct volume after mechanical thrombectomy.
    Bani-Sadr A; Cho TH; Cappucci M; Hermier M; Ameli R; Filip A; Riva R; Derex L; De Bourguignon C; Mechtouff L; Eker OF; Nighoghossian N; Berthezene Y
    J Neurointerv Surg; 2023 Apr; 15(4):393-398. PubMed ID: 35318959
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Is the optimal Tmax threshold identifying perfusion deficit volumes variable across MR perfusion software packages? A pilot study.
    Bani-Sadr A; Trintignac M; Mechtouff L; Hermier M; Cappucci M; Ameli R; de Bourguignon C; Derex L; Cho TH; Nighoghossian N; Eker OF; Berthezene Y
    MAGMA; 2023 Oct; 36(5):815-822. PubMed ID: 36811716
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of Perfusion CT Software to Predict the Final Infarct Volume After Thrombectomy.
    Austein F; Riedel C; Kerby T; Meyne J; Binder A; Lindner T; Huhndorf M; Wodarg F; Jansen O
    Stroke; 2016 Sep; 47(9):2311-7. PubMed ID: 27507864
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Prognostic Accuracy of CTP Summary Maps in Patients with Large Vessel Occlusive Stroke and Poor Revascularization after Mechanical Thrombectomy-Comparison of Three Automated Perfusion Software Applications.
    Muehlen I; Borutta M; Siedler G; Engelhorn T; Hock S; Knott M; Hoelter P; Volbers B; Schwab S; Doerfler A
    Tomography; 2022 May; 8(3):1350-1362. PubMed ID: 35645395
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of Two Automated Computed Tomography Perfusion Applications to Predict the Final Infarct Volume After Thrombolysis in Cerebral Infarction 3 Recanalization.
    Muehlen I; Sprügel M; Hoelter P; Hock S; Knott M; Huttner HB; Schwab S; Kallmünzer B; Doerfler A
    Stroke; 2022 May; 53(5):1657-1664. PubMed ID: 34872342
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Noncontrast Computed Tomography e-Stroke Infarct Volume Is Similar to RAPID Computed Tomography Perfusion in Estimating Postreperfusion Infarct Volumes.
    Bouslama M; Ravindran K; Harston G; Rodrigues GM; Pisani L; Haussen DC; Frankel MR; Nogueira RG
    Stroke; 2021 Jan; 52(2):634-641. PubMed ID: 33430633
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Assessment of computed tomography perfusion software in predicting spatial location and volume of infarct in acute ischemic stroke patients: a comparison of Sphere, Vitrea, and RAPID.
    Rava RA; Snyder KV; Mokin M; Waqas M; Zhang X; Podgorsak AR; Allman AB; Senko J; Shiraz Bhurwani MM; Hoi Y; Davies JM; Levy EI; Siddiqui AH; Ionita CN
    J Neurointerv Surg; 2021 Feb; 13(2):130-135. PubMed ID: 32457224
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Ischemic Core and Hypoperfusion Volumes Correlate With Infarct Size 24 Hours After Randomization in DEFUSE 3.
    Rao V; Christensen S; Yennu A; Mlynash M; Zaharchuk G; Heit J; Marks MP; Lansberg MG; Albers GW
    Stroke; 2019 Mar; 50(3):626-631. PubMed ID: 30727840
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Predictors of ghost infarct core on baseline computed tomography perfusion in stroke patients with successful recanalization after mechanical thrombectomy.
    Xu XQ; Ma G; Lu SS; Shen GC; Cao YZ; Liu S; Shi HB; Wu FY
    Eur Radiol; 2023 Mar; 33(3):1792-1800. PubMed ID: 36282310
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Brush sign and collateral supply as potential markers of large infarct growth after successful thrombectomy.
    Bani-Sadr A; Pavie D; Mechtouff L; Cappucci M; Hermier M; Ameli R; Derex L; De Bourguignon C; Cho TH; Eker O; Nighoghossian N; Berthezene Y
    Eur Radiol; 2023 Jun; 33(6):4502-4509. PubMed ID: 36633674
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of CT Perfusion Software Packages for Thrombectomy Eligibility.
    Pisani L; Haussen DC; Mohammaden M; Perry da Camara C; Jillella DV; Rodrigues GM; Bouslama M; Al-Bayati A; Prater A; Liberato B; Frankel MR; Nogueira RG
    Ann Neurol; 2023 Nov; 94(5):848-855. PubMed ID: 37584452
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Agreement and Accuracy of Ischemic Core Volume Evaluated by Three CT Perfusion Software Packages in Acute Ischemic Stroke.
    Liu QC; Jia ZY; Zhao LB; Cao YZ; Ma G; Shi HB; Liu S
    J Stroke Cerebrovasc Dis; 2021 Aug; 30(8):105872. PubMed ID: 34153591
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Automated CT Perfusion Imaging Versus Non-contrast CT for Ischemic Core Assessment in Large Vessel Occlusion.
    Tsang ACO; Lenck S; Hilditch C; Nicholson P; Brinjikji W; Krings T; Pereira VM; Silver FL; Schaafsma JD
    Clin Neuroradiol; 2020 Mar; 30(1):109-114. PubMed ID: 30470847
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Correlation between pretreatment and follow-up infarct volume using CT perfusion imaging: the Bayesian versus singular value decomposition method.
    Kawano H; Adachi T; Saito M; Amano T; Gomyo M; Yokoyama K; Shiokawa Y; Hirano T
    Neurol Sci; 2023 Jun; 44(6):2041-2047. PubMed ID: 36689012
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Modified Thrombolysis in Cerebral Infarction 2C/Thrombolysis in Cerebral Infarction 3 Reperfusion Should Be the Aim of Mechanical Thrombectomy: Insights From the ASTER Trial (Contact Aspiration Versus Stent Retriever for Successful Revascularization).
    Dargazanli C; Fahed R; Blanc R; Gory B; Labreuche J; Duhamel A; Marnat G; Saleme S; Costalat V; Bracard S; Desal H; Mazighi M; Consoli A; Piotin M; Lapergue B;
    Stroke; 2018 May; 49(5):1189-1196. PubMed ID: 29626134
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effect of different thresholds for CT perfusion volumetric analysis on estimated ischemic core and penumbral volumes.
    Karhi S; Tähtinen O; Aherto J; Matikka H; Manninen H; Nerg O; Taina M; Jäkälä P; Vanninen R
    PLoS One; 2021; 16(4):e0249772. PubMed ID: 33882098
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Higher agreement in endovascular treatment decision-making than in parametric quantifications among automated CT perfusion software packages in acute ischemic stroke.
    Pérez-Pelegrí M; Biarnés C; Thió-Henestrosa S; Remollo S; Gimeno A; Cuba V; Teceño M; Martí-Navas M; Serena J; Pedraza S; Ruiz-Constantino JS; Puig J
    J Xray Sci Technol; 2021; 29(5):823-834. PubMed ID: 34334443
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Automated versus manual imaging assessment of early ischemic changes in acute stroke: comparison of two software packages and expert consensus.
    Austein F; Wodarg F; Jürgensen N; Huhndorf M; Meyne J; Lindner T; Jansen O; Larsen N; Riedel C
    Eur Radiol; 2019 Nov; 29(11):6285-6292. PubMed ID: 31076862
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Early and Delayed Infarct Growth in Patients Undergoing Mechanical Thrombectomy: A Prospective, Serial MRI Study.
    Hernández-Pérez M; Werner M; Remollo S; Martín C; Cortés J; Valls A; Ramos A; Dorado L; Serena J; Munuera J; Puig J; Pérez de la Ossa N; Gomis M; Carbonell J; Castaño C; Muñoz-Narbona L; Palomeras E; Domenech S; Massuet A; Terceño M; Davalos A; Millán M
    Stroke; 2023 Jan; 54(1):217-225. PubMed ID: 36325911
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Ischemic core and hypoperfusion volumes predict infarct size in SWIFT PRIME.
    Albers GW; Goyal M; Jahan R; Bonafe A; Diener HC; Levy EI; Pereira VM; Cognard C; Cohen DJ; Hacke W; Jansen O; Jovin TG; Mattle HP; Nogueira RG; Siddiqui AH; Yavagal DR; Baxter BW; Devlin TG; Lopes DK; Reddy VK; de Rochemont Rdu M; Singer OC; Bammer R; Saver JL
    Ann Neurol; 2016 Jan; 79(1):76-89. PubMed ID: 26476022
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.