BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

182 related articles for article (PubMed ID: 35322526)

  • 1. End to end comparison of surface-guided imaging versus stereoscopic X-rays for the SRS treatment of multiple metastases with a single isocenter using 3D anthropomorphic gel phantoms.
    Bry V; Saenz D; Pappas E; Kalaitzakis G; Papanikolaou N; Rasmussen K
    J Appl Clin Med Phys; 2022 May; 23(5):e13576. PubMed ID: 35322526
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The development and testing of a novel spherical radiotherapy phantom system for the commissioning and patient-specific quality assurance of mono-isocentric multiple mets SRS plans.
    McKenna JT
    Med Phys; 2021 Jan; 48(1):105-113. PubMed ID: 33119902
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Stereotactic radiosurgery with MLC-defined arcs: Verification of dosimetry, spatial accuracy, and end-to-end tests.
    Brezovich IA; Wu X; Popple RA; Covington E; Cardan R; Shen S; Fiveash J; Bredel M; Guthrie B
    J Appl Clin Med Phys; 2019 May; 20(5):84-98. PubMed ID: 30977297
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Frame-based radiosurgery of multiple metastases using single-isocenter volumetric modulated arc therapy technique.
    Ahn KH; Yenice KM; Koshy M; Slavin KV; Aydogan B
    J Appl Clin Med Phys; 2019 Aug; 20(8):21-28. PubMed ID: 31328368
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Motion monitoring for cranial frameless stereotactic radiosurgery using video-based three-dimensional optical surface imaging.
    Li G; Ballangrud A; Kuo LC; Kang H; Kirov A; Lovelock M; Yamada Y; Mechalakos J; Amols H
    Med Phys; 2011 Jul; 38(7):3981-94. PubMed ID: 21858995
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A comprehensive investigation of the accuracy and reproducibility of a multitarget single isocenter VMAT radiosurgery technique.
    Thomas A; Niebanck M; Juang T; Wang Z; Oldham M
    Med Phys; 2013 Dec; 40(12):121725. PubMed ID: 24320511
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Efficient quality assurance method with automated data acquisition of a single phantom setup to determine radiation and imaging isocenter congruence.
    Kang H; Patel R; Roeske JC
    J Appl Clin Med Phys; 2019 Oct; 20(10):127-133. PubMed ID: 31535781
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Impact of patient positioning uncertainty in noncoplanar intracranial stereotactic radiotherapy.
    Tanaka Y; Oita M; Inomata S; Fuse T; Akino Y; Shimomura K
    J Appl Clin Med Phys; 2020 Feb; 21(2):89-97. PubMed ID: 31957975
    [TBL] [Abstract][Full Text] [Related]  

  • 9. An integrated quality assurance phantom for frameless single-isocenter multitarget stereotactic radiosurgery.
    Capaldi DPI; Skinner LB; Dubrowski P; Yu AS
    Phys Med Biol; 2020 Jun; 65(11):115006. PubMed ID: 32235050
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of Online 6 Degree-of-Freedom Image Registration of Varian TrueBeam Cone-Beam CT and BrainLab ExacTrac X-Ray for Intracranial Radiosurgery.
    Li J; Shi W; Andrews D; Werner-Wasik M; Lu B; Yu Y; Dicker A; Liu H
    Technol Cancer Res Treat; 2017 Jun; 16(3):339-343. PubMed ID: 28462690
    [TBL] [Abstract][Full Text] [Related]  

  • 11. ExacTrac Dynamic workflow evaluation: Combined surface optical/thermal imaging and X-ray positioning.
    Da Silva Mendes V; Reiner M; Huang L; Reitz D; Straub K; Corradini S; Niyazi M; Belka C; Kurz C; Landry G; Freislederer P
    J Appl Clin Med Phys; 2022 Oct; 23(10):e13754. PubMed ID: 36001389
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Stereoscopic X-ray imaging, cone beam CT, and couch positioning in stereotactic radiotherapy of intracranial tumors: preliminary results from a cross-modality pilot installation.
    Zollner B; Heinz C; Pitzler S; Manapov F; Kantz S; Rottler MC; Niyazi M; Ganswindt U; Belka C; Ballhausen H
    Radiat Oncol; 2016 Dec; 11(1):158. PubMed ID: 27927235
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Treatment planning system and beam data validation for the ZAP-X: A novel self-shielded stereotactic radiosurgery system.
    Srivastava SP; Jani SS; Pinnaduwage DS; Yan X; Rogers L; Barranco FD; Barani IJ; Sorensen S
    Med Phys; 2021 May; 48(5):2494-2510. PubMed ID: 33506520
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The spatial accuracy of two frameless, linear accelerator-based systems for single-isocenter, multitarget cranial radiosurgery.
    Ezzell GA
    J Appl Clin Med Phys; 2017 Mar; 18(2):37-43. PubMed ID: 28300379
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Single-isocenter stereotactic radiosurgery for multiple brain metastases: Impact of patient misalignments on target coverage in non-coplanar treatments.
    Eder MM; Reiner M; Heinz C; Garny S; Freislederer P; Landry G; Niyazi M; Belka C; Riboldi M
    Z Med Phys; 2022 Aug; 32(3):296-311. PubMed ID: 35504799
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Gantry triggered x-ray verification during single-isocenter stereotactic radiosurgery: Increased certainty for a no-margin strategy.
    Gutiérrez A; Gevaert T; Boussaer M; Everaert T; Ferro Teixeira C; De Ridder M
    Radiother Oncol; 2023 Sep; 186():109808. PubMed ID: 37468067
    [TBL] [Abstract][Full Text] [Related]  

  • 17. EXACTRAC x-ray and beam isocenters-what's the difference?
    Tideman Arp D; Carl J
    Med Phys; 2012 Mar; 39(3):1418-23. PubMed ID: 22380374
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Can Optical Surface Imaging Replace Non-coplanar Cone-beam Computed Tomography for Non-coplanar Set-up Verification in Single-isocentre Non-coplanar Stereotactic Radiosurgery and Hypofractionated Stereotactic Radiotherapy for Single and Multiple Brain Metastases?
    Lai JL; Liu SP; Jiang XX; Liu J; Li A; Li B; Li XK; Ye XJ; Lei KJ; Zhou L
    Clin Oncol (R Coll Radiol); 2023 Dec; 35(12):e657-e665. PubMed ID: 37778972
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Technical Note: Rotational positional error corrected intrafraction set-up margins in stereotactic radiotherapy: A spatial assessment for coplanar and noncoplanar geometry.
    Sarkar B; Munshi A; Ganesh T; Manikandan A; Krishnankutty S; Chitral L; Pradhan A; Kalyan Mohanti B
    Med Phys; 2019 Nov; 46(11):4749-4754. PubMed ID: 31495931
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The potential of an optical surface tracking system in non-coplanar single isocenter treatments of multiple brain metastases.
    Swinnen ACC; Öllers MC; Loon Ong C; Verhaegen F
    J Appl Clin Med Phys; 2020 Jun; 21(6):63-72. PubMed ID: 32237274
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.