These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
5. In Vitro Comparison of Pediatric Oxygenators With and Without Integrated Arterial Filters in Maintaining Optimal Hemodynamic Stability and Managing Gaseous Microemboli. Moroi M; Force M; Wang S; Kunselman AR; Ündar A Artif Organs; 2018 Apr; 42(4):420-431. PubMed ID: 29377185 [TBL] [Abstract][Full Text] [Related]
6. Evaluation of Capiox FX05 oxygenator with an integrated arterial filter on trapping gaseous microemboli and pressure drop with open and closed purge line. Qiu F; Peng S; Kunselman A; Ündar A Artif Organs; 2010 Nov; 34(11):1053-7. PubMed ID: 21137158 [TBL] [Abstract][Full Text] [Related]
7. Pulsatile and nonpulsatile extracorporeal circulation using Capiox E terumo oxygenator: a comparison study with Ultrox and Maxima membrane oxygenators. Minami K; Bairaktaris A; Murray E; Weitkemper H; Dramburg W; Körfer R J Cardiovasc Surg (Torino); 1997 Jun; 38(3):227-32. PubMed ID: 9219471 [TBL] [Abstract][Full Text] [Related]
8. Clinical evaluation of nine hollow-fibre membrane oxygenators. Segers PA; Heida JF; de Vries I; Maas C; Boogaart AJ; Eilander S Perfusion; 2001 Mar; 16(2):95-106. PubMed ID: 11334201 [TBL] [Abstract][Full Text] [Related]
9. In vitro elimination of gaseous microemboli utilizing hypobaric oxygenation in the Terumo® FX15 oxygenator. Clingan S; Schuldes M; Francis S; Hoerr H; Riley J Perfusion; 2016 Oct; 31(7):552-9. PubMed ID: 26993481 [TBL] [Abstract][Full Text] [Related]
11. Comparison of hollow-fiber membrane oxygenators in terms of pressure drop of the membranes during normothermic and hypothermic cardiopulmonary bypass in neonates. Undar A; Owens WR; McGarry MC; Surprise DL; Kilpack VD; Mueller MW; McKenzie ED; Fraser CD Perfusion; 2005 May; 20(3):135-8. PubMed ID: 16038384 [TBL] [Abstract][Full Text] [Related]
13. In Vitro Evaluation of Pediatric Hollow-Fiber Membrane Oxygenators on Hemodynamic Performance and Gaseous Microemboli Handling: An International Multicenter/Multidisciplinary Approach. Wang S; Caneo LF; Jatene MB; Jatene FB; Cestari IA; Kunselman AR; Ündar A Artif Organs; 2017 Sep; 41(9):865-874. PubMed ID: 28597590 [TBL] [Abstract][Full Text] [Related]
14. A clinical evaluation of the Terumo Capiox SX18R hollow fiber oxygenator. Dekkers PA; Lawson DS; Smigla GR; Shearer IR J Extra Corpor Technol; 1995 Sep; 27(3):152-7. PubMed ID: 10155360 [TBL] [Abstract][Full Text] [Related]
15. In vitro evaluation of gaseous microemboli handling of cardiopulmonary bypass circuits with and without integrated arterial line filters. Liu S; Newland RF; Tully PJ; Tuble SC; Baker RA J Extra Corpor Technol; 2011 Sep; 43(3):107-14. PubMed ID: 22164448 [TBL] [Abstract][Full Text] [Related]
16. Clinical gaseous microemboli assessment of an oxygenator with integral arterial filter in the pediatric population. Preston TJ; Gomez D; Olshove VF; Phillips A; Galantowicz M J Extra Corpor Technol; 2009 Dec; 41(4):226-30. PubMed ID: 20092077 [TBL] [Abstract][Full Text] [Related]
17. Effect of Normobaric versus Hypobaric Oxygenation on Gaseous Microemboli Removal in a Diffusion Membrane Oxygenator: An In Vitro Comparison. Schuldes M; Riley JB; Francis SG; Clingan S J Extra Corpor Technol; 2016 Sep; 48(3):129-136. PubMed ID: 27729706 [TBL] [Abstract][Full Text] [Related]
18. Additional veno-venous gas exchange as a problem-solving strategy for an oxygenator not transferring oxygen in paediatric cardiopulmonary bypass. Boettcher W; Sinzobahamvya N; Dehmel F; Matschke A; Iben A; Cho MY; Redlin M; Photiadis J Interact Cardiovasc Thorac Surg; 2017 Nov; 25(5):687-689. PubMed ID: 29049743 [TBL] [Abstract][Full Text] [Related]
19. Can the oxygenator screen filter reduce gaseous microemboli? Johagen D; Appelblad M; Svenmarker S J Extra Corpor Technol; 2014 Mar; 46(1):60-6. PubMed ID: 24779120 [TBL] [Abstract][Full Text] [Related]
20. Evaluation of membrane oxygenators and reservoirs in terms of capturing gaseous microemboli and pressure drops. Guan Y; Palanzo D; Kunselman A; Undar A Artif Organs; 2009 Nov; 33(11):1037-43. PubMed ID: 19874280 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]