These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
210 related articles for article (PubMed ID: 35357053)
1. Deep learning derived automated ASPECTS on non-contrast CT scans of acute ischemic stroke patients. Cao Z; Xu J; Song B; Chen L; Sun T; He Y; Wei Y; Niu G; Zhang Y; Feng Q; Ding Z; Shi F; Shen D Hum Brain Mapp; 2022 Jul; 43(10):3023-3036. PubMed ID: 35357053 [TBL] [Abstract][Full Text] [Related]
2. DGA3-Net: A parameter-efficient deep learning model for ASPECTS assessment for acute ischemic stroke using non-contrast computed tomography. Lin SY; Chiang PL; Chen MH; Lee MY; Lin WC; Chen YS Neuroimage Clin; 2023; 38():103441. PubMed ID: 37224605 [TBL] [Abstract][Full Text] [Related]
3. Prognosis with non-contrast CT and CT Perfusion imaging in thrombolysis-treated acute ischemic stroke. Chen X; Lin S; Zhang X; Hu S; Wang X Eur J Radiol; 2022 Apr; 149():110217. PubMed ID: 35183901 [TBL] [Abstract][Full Text] [Related]
4. Automated ASPECTS on Noncontrast CT Scans in Patients with Acute Ischemic Stroke Using Machine Learning. Kuang H; Najm M; Chakraborty D; Maraj N; Sohn SI; Goyal M; Hill MD; Demchuk AM; Menon BK; Qiu W AJNR Am J Neuroradiol; 2019 Jan; 40(1):33-38. PubMed ID: 30498017 [TBL] [Abstract][Full Text] [Related]
5. Validation of an automated ASPECTS method on non-contrast computed tomography scans of acute ischemic stroke patients. Kuang H; Qiu W; Najm M; Dowlatshahi D; Mikulik R; Poppe AY; Puig J; Castellanos M; Sohn SI; Ahn SH; Calleja A; Jin A; Asil T; Asdaghi N; Field TS; Coutts S; Hill MD; Demchuk AM; Goyal M; Menon BK; Int J Stroke; 2020 Jul; 15(5):528-534. PubMed ID: 31852412 [TBL] [Abstract][Full Text] [Related]
6. Total and regional ASPECT score for non-contrast CT, CT angiography, and CT perfusion: inter-rater agreement and its association with the final infarction in acute ischemic stroke patients. Chu Y; Ma G; Xu XQ; Lu SS; Cao YZ; Shi HB; Liu S; Wu FY Acta Radiol; 2022 Aug; 63(8):1093-1101. PubMed ID: 34219495 [TBL] [Abstract][Full Text] [Related]
7. EIS-Net: Segmenting early infarct and scoring ASPECTS simultaneously on non-contrast CT of patients with acute ischemic stroke. Kuang H; Menon BK; Sohn SI; Qiu W Med Image Anal; 2021 May; 70():101984. PubMed ID: 33676101 [TBL] [Abstract][Full Text] [Related]
8. Correlation of Alberta Stroke Program Early Computed Tomography Score With Computed Tomography Perfusion Core in Large Vessel Occlusion in Delayed Time Windows. Voleti S; Vidovich J; Corcoran B; Zhang B; Khandwala V; Mistry EA; Khatri P; Tomsick T; Vagal A Stroke; 2021 Jan; 52(2):498-504. PubMed ID: 33406866 [TBL] [Abstract][Full Text] [Related]
9. Clinical evaluation of a deep-learning model for automatic scoring of the Alberta stroke program early CT score on non-contrast CT. Lee SJ; Park G; Kim D; Jung S; Song S; Hong JM; Shin DH; Lee JS J Neurointerv Surg; 2023 Dec; 16(1):61-66. PubMed ID: 37015781 [TBL] [Abstract][Full Text] [Related]
10. A deep learning and radiomics based Alberta stroke program early CT score method on CTA to evaluate acute ischemic stroke. Fang T; Liu N; Nie S; Jia S; Ye X J Xray Sci Technol; 2024; 32(1):17-30. PubMed ID: 37980594 [TBL] [Abstract][Full Text] [Related]
11. Alberta Stroke Program Early CT Score and collateral status predict target mismatch in large vessel occlusion with delayed time windows. Hang Y; Wang CD; Ni H; Cao Y; Zhao LB; Liu S; Shi HB; Jia Z J Neurointerv Surg; 2023 Sep; 15(9):876-880. PubMed ID: 35790373 [TBL] [Abstract][Full Text] [Related]
12. Automated ASPECTS calculation may equal the performance of experienced clinicians: a machine learning study based on a large cohort. Wan S; Lu W; Fu Y; Wang M; Liu K; Chen S; Chen W; Wang Y; Wu J; Leng X; Fiehler J; Siddiqui AH; Guan S; Xiang J Eur Radiol; 2024 Mar; 34(3):1624-1634. PubMed ID: 37658137 [TBL] [Abstract][Full Text] [Related]
13. Diagnostic accuracy of using Alberta Stroke Program Early Computed Tomography Score on CT perfusion map to predict a target mismatch in patients with acute ischemic stroke. Chu Y; Shen GC; Ma G; Xu XQ; Lu SS; Jiang L; Liu S; Shi HB; Wu FY Neuroradiology; 2022 Jul; 64(7):1321-1330. PubMed ID: 34981174 [TBL] [Abstract][Full Text] [Related]
14. Automatic assessment of DWI-ASPECTS for acute ischemic stroke based on deep learning. Fang T; Jiang Z; Zhou Y; Jia S; Zhao J; Nie S Med Phys; 2024 Jun; 51(6):4351-4364. PubMed ID: 38687043 [TBL] [Abstract][Full Text] [Related]
15. Performance of e-ASPECTS software in comparison to that of stroke physicians on assessing CT scans of acute ischemic stroke patients. Herweh C; Ringleb PA; Rauch G; Gerry S; Behrens L; Möhlenbruch M; Gottorf R; Richter D; Schieber S; Nagel S Int J Stroke; 2016 Jun; 11(4):438-45. PubMed ID: 26880058 [TBL] [Abstract][Full Text] [Related]
16. Multiphase computed tomography angiography (mCTA) derived source images in acute ischemic stroke: Beyond collaterals. Can it obviate the need for computed tomography perfusion (CTP)? Gupta A; Garg PK; Khera PS; Panda S; Bohra GK; Yadav T; Garg MK; Tiwari S Clin Neurol Neurosurg; 2022 Nov; 222():107421. PubMed ID: 36067545 [TBL] [Abstract][Full Text] [Related]