These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
142 related articles for article (PubMed ID: 35395379)
1. Initial Study of the Extended STABILISE Technique for Complete Remodeling in Aortic Dissection. Langouet Q; Marchand E; Nauta A; Loreille F; Aupart M; Bourguignon T; Martinez R Ann Vasc Surg; 2022 Oct; 86():373-379. PubMed ID: 35395379 [TBL] [Abstract][Full Text] [Related]
2. Distal Extended Endovascular Aortic Repair PETTICOAT: A Modified Technique to Improve False Lumen Remodeling in Acute Type B Aortic Dissection. Molinari AC; Leo E; Ferraresi M; Ferrari SA; Terzi A; Sommaruga S; Rossi G Ann Vasc Surg; 2019 Aug; 59():300-305. PubMed ID: 31075476 [TBL] [Abstract][Full Text] [Related]
3. The STABILISE technique to address malperfusion on acute-subacute type B aortic dissections. Mascia D; Rinaldi E; Kahlberg A; Monaco F; DE Luca M; Chiesa R; Melissano G J Cardiovasc Surg (Torino); 2022 Apr; 63(2):131-136. PubMed ID: 35238521 [TBL] [Abstract][Full Text] [Related]
4. Stent-assisted, balloon-induced intimal disruption and relamination of aortic dissection in patients with Marfan syndrome: Midterm outcomes and aortic remodeling. Faure EM; El Batti S; Abou Rjeili M; Ben Abdallah I; Julia P; Alsac JM J Thorac Cardiovasc Surg; 2018 Nov; 156(5):1787-1793. PubMed ID: 29934004 [TBL] [Abstract][Full Text] [Related]
5. Thoracic Endovascular Aortic Repair on Zone 2 Landing for Type B Aortic Dissection. Miura S; Kurimoto Y; Maruyama R; Wada T; Konno M; Iba Y; Hatta E; Yamada A Ann Vasc Surg; 2019 Oct; 60():120-127. PubMed ID: 31075454 [TBL] [Abstract][Full Text] [Related]
6. Volumetric analysis in primary and residual type B aortic dissection treated with stented-assisted balloon-induced intimal disruption and relamination technique can predict aortic reintervention. Ferraresi M; Molinari ACL; Katsarou M; Rossi G J Vasc Surg; 2024 Jun; 79(6):1315-1325. PubMed ID: 38382641 [TBL] [Abstract][Full Text] [Related]
7. Fate and Consequences of the False Lumen After Thoracic Endovascular Aortic Repair in Type B Aortic Dissection. Jubouri M; Patel R; Tan SZ; Al-Tawil M; Bashir M; Bailey DM; Williams IM Ann Vasc Surg; 2023 Aug; 94():32-37. PubMed ID: 36309167 [TBL] [Abstract][Full Text] [Related]
8. Mid-term Outcomes of Stent Assisted Balloon Induced Intimal Disruption and Relamination in Aortic Dissection Repair (STABILISE) in Acute Type B Aortic Dissection. Faure EM; El Batti S; Abou Rjeili M; Julia P; Alsac JM Eur J Vasc Endovasc Surg; 2018 Aug; 56(2):209-215. PubMed ID: 29891434 [TBL] [Abstract][Full Text] [Related]
9. Technique-Based Evaluation of Clinical Outcomes and Aortic Remodelling Following TEVAR in Acute and Subacute Type B Aortic Dissection. Zhong J; Osman A; Tingerides C; Puppala S; Shaw D; McPherson S; Darwood R; Walker P Cardiovasc Intervent Radiol; 2021 Apr; 44(4):537-547. PubMed ID: 33388868 [TBL] [Abstract][Full Text] [Related]
10. Volume analysis of true and false lumens in acute complicated type B aortic dissections after thoracic endovascular aortic repair with stent grafts alone or with a composite device design. Sobocinski J; Lombardi JV; Dias NV; Berger L; Zhou Q; Jia F; Resch T; Haulon S J Vasc Surg; 2016 May; 63(5):1216-24. PubMed ID: 26806523 [TBL] [Abstract][Full Text] [Related]
11. Impact of proximal seal zone length and intramural hematoma on clinical outcomes and aortic remodeling after thoracic endovascular aortic repair for aortic dissections. Kuo EC; Veranyan N; Johnson CE; Weaver FA; Ham SW; Rowe VL; Fleischman F; Bowdish M; Han SM J Vasc Surg; 2019 Apr; 69(4):987-995. PubMed ID: 30528404 [TBL] [Abstract][Full Text] [Related]
12. Modified Petticoat Technique with Pre-placement of a Distal Bare Stent Improves Early Aortic Remodeling after Complicated Acute Stanford Type B Aortic Dissection. He H; Yao K; Nie WP; Wang Z; Liang Q; Shu C; Dardik A Eur J Vasc Endovasc Surg; 2015 Oct; 50(4):450-9. PubMed ID: 26100449 [TBL] [Abstract][Full Text] [Related]
13. Initial results of thoracic endovascular repair for uncomplicated type B aortic dissection involving the arch vessels using a semicustom-made thoracic fenestrated stent graft. Fukushima S; Ohki T; Toya N; Shukuzawa K; Ito E; Murakami Y; Akiba T J Vasc Surg; 2019 Jun; 69(6):1694-1703. PubMed ID: 30786986 [TBL] [Abstract][Full Text] [Related]
14. Stent-assisted balloon-induced intimal disruption and relamination of distal remaining aortic dissection after acute DeBakey type I repair. Faure EM; El Batti S; Sutter W; Bel A; Julia P; Achouh P; Alsac JM J Thorac Cardiovasc Surg; 2019 Jun; 157(6):2159-2165. PubMed ID: 30501951 [TBL] [Abstract][Full Text] [Related]
15. Outcomes from the Gore Global Registry for Endovascular Aortic Treatment in patients undergoing thoracic endovascular aortic repair for type B dissection. Tjaden BL; Sandhu H; Miller C; Gable D; Trimarchi S; Weaver F; Azizzadeh A J Vasc Surg; 2018 Nov; 68(5):1314-1323. PubMed ID: 29941315 [TBL] [Abstract][Full Text] [Related]
16. Emergency endovascular stent-grafting for acute type B aortic dissection with symptomatic malperfusion. Shu C; Fang K; Luo M; Li Q; Wang Z Int Angiol; 2013 Oct; 32(5):483-91. PubMed ID: 23903307 [TBL] [Abstract][Full Text] [Related]
17. Surgical Outcomes And Postoperative Descending Aorta Morphologic Remodeling After Thoracic Endovascular Aortic Repair For Acute And Chronic Type B Aortic Dissection. Zha B; Qiu P; Xie W; Zhang Z; Li Y; Chen Z; Zhu H Clin Interv Aging; 2019; 14():1925-1935. PubMed ID: 31806948 [TBL] [Abstract][Full Text] [Related]
18. Restrictive bare stent prevents distal stent graft-induced new entry in endovascular repair of type B aortic dissection. Zhao Y; Yin H; Chen Y; Wang M; Zheng L; Li Z; Chang G J Vasc Surg; 2018 Jan; 67(1):93-103. PubMed ID: 28711399 [TBL] [Abstract][Full Text] [Related]
19. Satisfactory short-term outcomes of the STABILISE technique for type B aortic dissection. Melissano G; Bertoglio L; Rinaldi E; Mascia D; Kahlberg A; Loschi D; De Luca M; Monaco F; Chiesa R J Vasc Surg; 2018 Oct; 68(4):966-975. PubMed ID: 29606568 [TBL] [Abstract][Full Text] [Related]
20. Coil Embolization for Persistent Thoracic False Lumen of Type B Aortic Dissection after Thoracic Endovascular Aortic Repair. Zhang H; Ge YY; Lu K; Cao L; Liu P; Liu XP; Wang LJ; Guo W Ann Vasc Surg; 2019 May; 57():60-68. PubMed ID: 30684608 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]