These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

119 related articles for article (PubMed ID: 35396722)

  • 1. Development of a dosimetry system for therapeutic X-rays using a flexible amorphous silicon thin-film solar cell with a scintillator screen.
    Jeong S; Cheon W; Shin D; Lim YK; Jeong J; Kim H; Yoon M; Lee SB
    Med Phys; 2022 Jul; 49(7):4768-4779. PubMed ID: 35396722
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Development of a real-time in vivo dosimetry tool for electron beam therapy using a flexible thin film solar cell coated with scintillator powder.
    Jeong S; An S; Kwon YC; Pak SI; Cheon W; Shin D; Lim YK; Jeong JH; Kim H; Lee SB
    Med Phys; 2023 Jan; 50(1):557-569. PubMed ID: 35993665
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Flexible real-time skin dosimeter based on a thin-film copper indium gallium selenide solar cell for electron radiation therapy.
    Shin DS; Kim TH; Rah JE; Lee SB; Lim YK; Jeong J; Kim H; Shin D; Son J
    Med Phys; 2023 Apr; 50(4):2402-2416. PubMed ID: 36583513
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Development of a silicon diode detector for skin dosimetry in radiotherapy.
    Vicoroski N; Espinoza A; Duncan M; Oborn BM; Carolan M; Metcalfe P; Menichelli D; Perevertaylo VL; Lerch MLF; Rosenfeld AB; Petasecca M
    Med Phys; 2017 Oct; 44(10):5402-5412. PubMed ID: 28696500
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Low-cost flexible thin-film detector for medical dosimetry applications.
    Zygmanski P; Abkai C; Han Z; Shulevich Y; Menichelli D; Hesser J
    J Appl Clin Med Phys; 2014 Mar; 15(2):4454. PubMed ID: 24710432
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of an a-Si EPID in direct detection configuration as a water-equivalent dosimeter for transit dosimetry.
    Sabet M; Menk FW; Greer PB
    Med Phys; 2010 Apr; 37(4):1459-67. PubMed ID: 20443467
    [TBL] [Abstract][Full Text] [Related]  

  • 7. SU-E-T-163: Thin-Film Organic Photocell (OPV) Properties in MV and KV Beams for Dosimetry Applications.
    Ng SK; Hesser J; Zhang H; Gowrisanker S; Yakushevich S; Shulhevich Y; Abkai C; Wack L; Zygmanski P
    Med Phys; 2012 Jun; 39(6Part12):3740. PubMed ID: 28517827
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Characterization of an organic semiconductor diode for dosimetry in radiotherapy.
    Posar JA; Davis J; Large MJ; Basiricò L; Ciavatti A; Fraboni B; Dhez O; Wilkinson D; Sellin PJ; Griffith MJ; Lerch MLF; Rosenfeld A; Petasecca M
    Med Phys; 2020 Aug; 47(8):3658-3668. PubMed ID: 32395821
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison and uncertainty evaluation of different calibration protocols and ionization chambers for low-energy surface brachytherapy dosimetry.
    Candela-Juan C; Vijande J; García-Martínez T; Niatsetski Y; Nauta G; Schuurman J; Ouhib Z; Ballester F; Perez-Calatayud J
    Med Phys; 2015 Aug; 42(8):4954-64. PubMed ID: 26233221
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Measuring small field profiles and output factors with a stemless plastic scintillator array.
    Hupman MA; Hill IG; Syme A
    Med Phys; 2022 Jan; 49(1):624-631. PubMed ID: 34792193
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparative dosimetry in narrow high-energy photon beams.
    Westermark M; Arndt J; Nilsson B; Brahme A
    Phys Med Biol; 2000 Mar; 45(3):685-702. PubMed ID: 10730964
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Technical note: Characterization and practical applications of a novel plastic scintillator for online dosimetry for an ultrahigh dose rate (FLASH).
    Poirier Y; Xu J; Mossahebi S; Therriault-Proulx F; Sawant A
    Med Phys; 2022 Jul; 49(7):4682-4692. PubMed ID: 35462420
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Dosimetric characterization and behaviour in small X-ray fields of a microchamber and a plastic scintillator detector.
    Pasquino M; Cutaia C; Radici L; Valzano S; Gino E; Cavedon C; Stasi M
    Br J Radiol; 2017 Jan; 90(1069):20160596. PubMed ID: 27826990
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Assessment of a Therapeutic X-ray Radiation Dose Measurement System Based on a Flexible Copper Indium Gallium Selenide Solar Cell.
    Shin DS; Kim TH; Rah JE; Kim D; Yang HJ; Lee SB; Lim YK; Jeong J; Kim H; Shin D; Son J
    Sensors (Basel); 2022 Aug; 22(15):. PubMed ID: 35957376
    [TBL] [Abstract][Full Text] [Related]  

  • 15. AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams.
    Almond PR; Biggs PJ; Coursey BM; Hanson WF; Huq MS; Nath R; Rogers DW
    Med Phys; 1999 Sep; 26(9):1847-70. PubMed ID: 10505874
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Characterization of the plastic scintillation detector Exradin W2 for small field dosimetry.
    Galavis PE; Hu L; Holmes S; Das IJ
    Med Phys; 2019 May; 46(5):2468-2476. PubMed ID: 30897221
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Development of an accurate EPID-based output measurement and dosimetric verification tool for electron beam therapy.
    Ding A; Xing L; Han B
    Med Phys; 2015 Jul; 42(7):4190-8. PubMed ID: 26133618
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Characterizing energy dependence and count rate performance of a dual scintillator fiber-optic detector for computed tomography.
    Hoerner MR; Stepusin EJ; Hyer DE; Hintenlang DE
    Med Phys; 2015 Mar; 42(3):1268-79. PubMed ID: 25735282
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of a micro ionization chamber for dosimetric measurements in image-guided preclinical irradiation platforms.
    Silvestre Patallo I; Carter R; Maughan D; Nisbet A; Schettino G; Subiel A
    Phys Med Biol; 2021 Dec; 66(24):. PubMed ID: 34794132
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Integrating X-ray kV millimetric field dosimetry with a synthetic diamond detector into the treatment planning system commissioning of a preclinical irradiator.
    Muñoz Arango E; Beltrán Gómez C; Alaminos-Bouza A; de Almeida CE
    Med Phys; 2021 Jul; 48(7):4038-4052. PubMed ID: 33797098
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.