127 related articles for article (PubMed ID: 35404814)
1. Comprehensive Comparison of Image Quality Aspects Between Conventional and Plane-Wave Imaging Methods on a Commercial Scanner.
Hendriks GAGM; Weijers G; Chen C; Hertel M; Lee CY; Dueppenbecker PM; Radicke M; Milkowski A; Hansen HHG; de Korte CL
IEEE Trans Ultrason Ferroelectr Freq Control; 2022 Jun; 69(6):2039-2049. PubMed ID: 35404814
[TBL] [Abstract][Full Text] [Related]
2. The Spectrum-Beamformer for Conventional B-Mode Ultrasound Imaging System: Principle, Validation, and Robustness.
Jiang C; Liu C; Zhan Y; Ta D
Ultrason Imaging; 2022 May; 44(2-3):59-76. PubMed ID: 35373649
[TBL] [Abstract][Full Text] [Related]
3. Plane-Wave Compounding in Automated Breast Volume Scanning: A Phantom-Based Study.
Holländer B; Hendriks GA; Mann RM; Hansen HH; de Korte CL
Ultrasound Med Biol; 2016 Oct; 42(10):2493-503. PubMed ID: 27401958
[TBL] [Abstract][Full Text] [Related]
4. Optimized Plane Wave Imaging for Fast and High-Quality Ultrasound Imaging.
Jensen J; Stuart MB; Jensen JA
IEEE Trans Ultrason Ferroelectr Freq Control; 2016 Nov; 63(11):1922-1934. PubMed ID: 27824568
[TBL] [Abstract][Full Text] [Related]
5. Evaluations of UltraiQ software for objective ultrasound image quality assessment using images from a commercial scanner.
Long Z; Tradup DJ; Stekel SF; Gorny KR; Hangiandreou NJ
J Appl Clin Med Phys; 2018 Mar; 19(2):298-304. PubMed ID: 29336119
[TBL] [Abstract][Full Text] [Related]
6. Ultrasound plane-wave imaging with delay multiply and sum beamforming and coherent compounding.
Matrone G; Savoia AS; Caliano G; Magenes G
Annu Int Conf IEEE Eng Med Biol Soc; 2016 Aug; 2016():3223-3226. PubMed ID: 28268994
[TBL] [Abstract][Full Text] [Related]
7. Optimization of transmission and reconstruction parameters in angular displacement compounding using plane wave ultrasound.
Hendriks GAGM; Hansen HHG; De Korte CL; Chen C
Phys Med Biol; 2020 Apr; 65(8):085007. PubMed ID: 32109889
[TBL] [Abstract][Full Text] [Related]
8. Improved contrast for high frame rate imaging using coherent compounding combined with spatial matched filtering.
Lou Y; Yen JT
Ultrasonics; 2017 Jul; 78():152-161. PubMed ID: 28351747
[TBL] [Abstract][Full Text] [Related]
9. Stolt's f-k migration for plane wave ultrasound imaging.
Garcia D; Le Tarnec L; Muth S; Montagnon E; Porée J; Cloutier G
IEEE Trans Ultrason Ferroelectr Freq Control; 2013 Sep; 60(9):1853-67. PubMed ID: 24626107
[TBL] [Abstract][Full Text] [Related]
10. Improving Image Quality for Single-Angle Plane Wave Ultrasound Imaging With Convolutional Neural Network Beamformer.
Lu JY; Lee PY; Huang CC
IEEE Trans Ultrason Ferroelectr Freq Control; 2022 Apr; 69(4):1326-1336. PubMed ID: 35175918
[TBL] [Abstract][Full Text] [Related]
11. Improved Plane-Wave Ultrasound Beamforming by Incorporating Angular Weighting and Coherent Compounding in Fourier Domain.
Chen C; Hendriks GAGM; van Sloun RJG; Hansen HHG; de Korte CL
IEEE Trans Ultrason Ferroelectr Freq Control; 2018 May; 65(5):749-765. PubMed ID: 29733279
[TBL] [Abstract][Full Text] [Related]
12. Converting Coherence to Signal-to-noise Ratio for Enhancement of Adaptive Ultrasound Imaging.
Hasegawa H; Nagaoka R
Ultrason Imaging; 2020 Jan; 42(1):27-40. PubMed ID: 31802696
[TBL] [Abstract][Full Text] [Related]
13. Complex Transformer Network for Single-Angle Plane-Wave Imaging.
Qu X; Ren C; Wang Z; Fan S; Zheng D; Wang S; Lin H; Jiang J; Xing W
Ultrasound Med Biol; 2023 Oct; 49(10):2234-2246. PubMed ID: 37544831
[TBL] [Abstract][Full Text] [Related]
14. Fresnel-based beamforming for low-cost portable ultrasound.
Nguyen MM; Mung J; Yen JT
IEEE Trans Ultrason Ferroelectr Freq Control; 2011 Jan; 58(1):112-21. PubMed ID: 21244979
[TBL] [Abstract][Full Text] [Related]
15. DMAS Beamforming with Complementary Subset Transmit for Ultrasound Coherence-Based Power Doppler Detection in Multi-Angle Plane-Wave Imaging.
Shen CC; Chu YC
Sensors (Basel); 2021 Jul; 21(14):. PubMed ID: 34300594
[TBL] [Abstract][Full Text] [Related]
16. Adaptive Multifocus Beamforming for Contrast-Enhanced-Super-Resolution Ultrasound Imaging in Deep Tissue.
Espindola D; Lin F; Soulioti DE; Dayton PA; Pinton GF
IEEE Trans Ultrason Ferroelectr Freq Control; 2018 Dec; 65(12):2255-2263. PubMed ID: 30136938
[TBL] [Abstract][Full Text] [Related]
17. Evaluation of a novel collimator for molecular breast tomosynthesis.
Gilland DR; Welch BL; Lee S; Kross B; Weisenberger AG
Med Phys; 2017 Nov; 44(11):5740-5748. PubMed ID: 28877351
[TBL] [Abstract][Full Text] [Related]
18. Ultrasound grayscale image quality comparison between a 2D intracavitary transducer and a 3D intracavitary transducer used in 2D mode: A phantom study.
Zhou W; Long Z; Tradup DJ; Stekel SF; Browne JE; Brown DL; Hangiandreou NJ
J Appl Clin Med Phys; 2019 Jun; 20(6):134-140. PubMed ID: 31002482
[TBL] [Abstract][Full Text] [Related]
19. Deep Learning to Obtain Simultaneous Image and Segmentation Outputs From a Single Input of Raw Ultrasound Channel Data.
Nair AA; Washington KN; Tran TD; Reiter A; Lediju Bell MA
IEEE Trans Ultrason Ferroelectr Freq Control; 2020 Dec; 67(12):2493-2509. PubMed ID: 32396084
[TBL] [Abstract][Full Text] [Related]
20. Benefits of minimum-variance beamforming in medical ultrasound imaging.
Synnevag JF; Austeng A; Holm S
IEEE Trans Ultrason Ferroelectr Freq Control; 2009 Sep; 56(9):1868-79. PubMed ID: 19811990
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]