These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

154 related articles for article (PubMed ID: 35417049)

  • 1. Patient related outcomes of mechanical lead extraction techniques (PROMET) study: A comparison of two professions.
    Akhtar Z; Gallagher MM; Elbatran AI; Starck CT; Gonzalez E; Al-Razzo O; Mazzone P; Delnoy PP; Breitenstein A; Steffel J; Eulert-Grehn J; Lanmüller P; Melillo F; Marzi A; Leung LW; Domenichini G; Sohal M
    Pacing Clin Electrophysiol; 2022 May; 45(5):658-665. PubMed ID: 35417049
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Mechanical extraction of implantable cardioverter-defibrillator leads with a dwell time of more than 10 years: insights from a single high-volume centre.
    Ząbek A; Boczar K; Ulman M; Holcman K; Kostkiewicz M; Pfitzner R; Dębski M; Musiał R; Lelakowski J; Małecka B
    Europace; 2023 Mar; 25(3):1100-1109. PubMed ID: 36660771
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Results of the Patient-Related Outcomes of Mechanical lead Extraction Techniques (PROMET) study: a multicentre retrospective study on advanced mechanical lead extraction techniques.
    Starck CT; Gonzalez E; Al-Razzo O; Mazzone P; Delnoy PP; Breitenstein A; Steffel J; Eulert-Grehn J; Lanmüller P; Melillo F; Marzi A; Sohal M; Domenichini G; Gallagher MM
    Europace; 2020 Jul; 22(7):1103-1110. PubMed ID: 32447388
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Transvenous lead extraction: The influence of age on patient outcomes in the PROMET study cohort.
    Akhtar Z; Elbatran AI; Starck CT; Gonzalez E; Al-Razzo O; Mazzone P; Delnoy PP; Breitenstein A; Steffel J; Eulert-Grehn J; Lanmüller P; Melillo F; Marzi A; Leung LWM; Domenichini G; Sohal M; Gallagher MM
    Pacing Clin Electrophysiol; 2021 Sep; 44(9):1540-1548. PubMed ID: 34235772
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Transvenous extraction of permanent pacemaker and defibrillator leads: Reduced procedural complexity and higher procedural success rates in patients with infective versus noninfective indications.
    Archontakis S; Pirounaki M; Aznaouridis K; Karageorgopoulos D; Sideris K; Tolios P; Triantafyllou K; Gatzoulis K; Tousoulis D; Sideris S
    J Cardiovasc Electrophysiol; 2021 Feb; 32(2):491-499. PubMed ID: 33345428
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The valuable interaction among cardiac surgeon and electrophysiologist for transvenous rotational mechanical lead extraction.
    Migliore F; Tarzia V; Dall'Aglio PB; Falzone PV; De Lazzari M; Bottio T; D'Onofrio A; Padalino M; Vida V; Rosso J; Leoni L; Pittarello D; Bertaglia E; Iliceto S; Gerosa G
    Pacing Clin Electrophysiol; 2022 Jan; 45(1):92-102. PubMed ID: 34699079
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Risk Factors and Long-Term Survival of Octogenarians and Nonagenarians Undergoing Transvenous Lead Extraction Procedures.
    Jacheć W; Polewczyk A; Segreti L; Bongiorni MG; Kutarski A
    Gerontology; 2021; 67(1):36-48. PubMed ID: 33242867
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Outcomes of transvenous lead extraction of very old leads using bidirectional rotational mechanical sheaths: Results of a multicentre study.
    Migliore F; Pittorru R; Dall'Aglio PB; De Lazzari M; Rovaris G; Piazzi E; Dentico A; Ferrieri A; D'Angelo G; Marzi A; Sawaf BE; Bertaglia E; Iliceto S; Gerosa G; Tarzia V; Carretta D; Mazzone P
    J Cardiovasc Electrophysiol; 2023 Mar; 34(3):728-737. PubMed ID: 36477909
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Persistent left superior vena cava transvenous lead extraction: A European experience.
    Akhtar Z; Sohal M; Starck CT; Mazzone P; Melillo F; Gonzalez E; Al-Razzo O; Richter S; Breitenstein A; Steffel J; Rinaldi CA; Mehta V; Zuberi Z; Zaidi A; Gallagher MM
    J Cardiovasc Electrophysiol; 2022 Jan; 33(1):102-108. PubMed ID: 34783107
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Outcome of transvenous lead extraction of leads older than 20 years.
    Issa ZF
    J Cardiovasc Electrophysiol; 2021 Nov; 32(11):3042-3048. PubMed ID: 34453369
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Clinical predictors of adverse patient outcomes in an experience of more than 5000 chronic endovascular pacemaker and defibrillator lead extractions.
    Brunner MP; Cronin EM; Duarte VE; Yu C; Tarakji KG; Martin DO; Callahan T; Cantillon DJ; Niebauer MJ; Saliba WI; Kanj M; Wazni O; Baranowski B; Wilkoff BL
    Heart Rhythm; 2014 May; 11(5):799-805. PubMed ID: 24444444
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Transvenous extraction of implantable cardioverter-defibrillator leads under advisory--a comparison of Riata, Sprint Fidelis, and non-recalled implantable cardioverter-defibrillator leads.
    Brunner MP; Cronin EM; Jacob J; Duarte VE; Tarakji KG; Martin DO; Callahan T; Borek PP; Cantillon DJ; Niebauer MJ; Saliba WI; Kanj M; Wazni O; Baranowski B; Wilkoff BL
    Heart Rhythm; 2013 Oct; 10(10):1444-50. PubMed ID: 23816440
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Procedural outcomes associated with transvenous lead extraction in patients with abandoned leads: an ESC-EHRA ELECTRa (European Lead Extraction ConTRolled) Registry Sub-Analysis.
    Segreti L; Rinaldi CA; Claridge S; Svendsen JH; Blomstrom-Lundqvist C; Auricchio A; Butter C; Dagres N; Deharo JC; Maggioni AP; Kutarski A; Kennergren C; Laroche C; Kempa M; Magnani A; Casteigt B; Bongiorni MG;
    Europace; 2019 Apr; 21(4):645-654. PubMed ID: 30624715
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Transvenous lead extraction in patients with prior extraction procedures: Procedural profiles and outcomes.
    Hutt E; Diab M; Wazni OM; Kaur S; Tarakji KG; Saliba WI; Kanj M; Cantillon D; Rickard J; Varma N; Callahan T; Martin DO; Niebauer M; Dresing T; Chung M; Wilkoff BL; Hussein AA
    Heart Rhythm; 2020 Nov; 17(11):1904-1908. PubMed ID: 32512177
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of acute and long-term outcomes of Evolution
    Bahadır N; Canpolat U; Kaya EB; Sahiner ML; Ateş AH; Yorgun H; Aytemir K
    J Cardiovasc Electrophysiol; 2021 May; 32(5):1395-1404. PubMed ID: 33724617
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Low Utilization of Lead Extraction Among Patients With Infective Endocarditis and Implanted Cardiac Electronic Devices.
    Sciria CT; Kogan EV; Mandler AG; Yeo I; Simon MS; Kim LK; Ip JE; Liu CF; Markowitz SM; Lerman BB; Thomas G; Cheung JW
    J Am Coll Cardiol; 2023 May; 81(17):1714-1725. PubMed ID: 37100488
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Outcomes of cardiac implantable electronic device transvenous lead extractions performed in centers without onsite cardiac surgery.
    Mohamed MO; Greenspon A; Contractor T; Rashid M; Kwok CS; Potts J; Barker D; Patwala A; Mamas MA
    Int J Cardiol; 2020 Feb; 300():154-160. PubMed ID: 31402163
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Disparities in transvenous lead extraction in young adults.
    Kutarski A; Jacheć W; Tułecki Ł; Czajkowski M; Nowosielecka D; Stefańczyk P; Tomków K; Polewczyk A
    Sci Rep; 2022 Jun; 12(1):9601. PubMed ID: 35689031
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Mechanical extraction of cardiac implantable electronic devices leads with long dwell time: Efficacy and safety of the step up approach.
    Lensvelt LMH; Egorova AD; Schalij MJ; Yilmaz D; Kennergren C; Bootsma M; van Erven L
    Pacing Clin Electrophysiol; 2021 Jan; 44(1):120-128. PubMed ID: 33067867
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The analysis of indications and early results of transvenous lead extraction in patients with a pacemaker, ICD and CRT - single-center experience.
    Zabek A; Malecka B; Haberka K; Boczar K; Pfitzner R; Debski M; Lelakowski J
    Acta Cardiol; 2015 Dec; 70(6):685-92. PubMed ID: 26717217
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.